HomeMy WebLinkAbout0481.0921
. -,
-,
'-
/
:----,-,~----',,'''"
october 26, 1992
THE HONORABLE CITY COUNCIL
Palo Alto, California
'FA Llap AND COPPZ~ RULI aND PAUQ ALTO I ' TBeT RESPLTS
Members ot the Council:
This is an intorma~ional staff report which provides an update on
the EPA's Lead and copper Rule, the results of Palo Alto's first
round of testinq for lead and copper and required public
notification~
IPA LPP AIm COPPBR RULE III BRIEF
The Sare Drinking Water Act {SDWA), which was enacted by Congress
in 1974. qave the u~s. Environmental Protection Agency (EPA} the
federal authority to establish drinking water-standards. In
1975, the EPA established a primary drinking water standard for
lead of 0.050 milliqrams per liter (mq/l) and a secondary
drinkin9 water standard for copper of 1.0 ~9/1. A primary
drinking water standa~d is established to protect health and, if
e~ceeded, requires public notification. A secondary drinking
water standard is established for aesthetic reasons and does not
require pUblic notificatio~ if exceeded.
In 1986 Congress ~ade significa~t amendments to the SDWA and
established a list of 33 contaminants fo~ which EPA was to
develop drinkipg water standards~ Lead and copper were among
those contaminants. EPA respond~d in 1988 by proposing a rule
that included primary drinking water standards for both lead and
copper, and requirements such as corrosion-control treatment for
water systems. After receiving nationwide comments on the
proposed rule and after developing a number of drafts, EPA
announced the Lead and copper Rule on June 7, 1991.
The basic elements of the Lead and Ccpper Rule are as follows:
1. All large water systems are required to test for lead and
copper a~ various points in the distrib~tior. system and at
points of entry into the distribution system.
CXlt: &81: 92
•
/
, " -.
. ~.
2. The EPA determined that fQr 'Water utilities the size of PIII.lo
Alto 60 ho~es should be tested. They used the following
c~iteria in attempting to identify homes most likely to have
lead a~d/or copper problems;
a.) built aftp-r 1992 1 and
b.) utilizing copper piping joined ~ith lead solder.
T~st1nq was done on water t~ken from ~ faucet inside the
home on a first draw (no water \lsag·e tor at least six
hours).
3. All water systems serving more than 50,00e persons are also
required to do corrosion control studies which must be
complete"_ by July 1, 1994.
04. For all 'Water s}'-stems • ... here roughly 10 percent of samples
tested Exceed the action levels of 15 parts per billion
(ppb) lead or 1300 parts per billion (ppb) copper, the
following actions are required:
o Optimal corrosion control.
Public notification/education.
Leaa service line replacement ,Not applicable to Palo
Alto where th~re are no lead service lines.j
PStJLTS or PALO ALTO'S FIRST RQPIID or 'fEB_TING
In September r tests on samples taken from the distribution system
and the points of entry into the distribution system .... ere non
detectable for both lead and copper. This indicates that the
lead and copper levels in Palo Alto's water supply fall far below
the EPA maximum limits~ (The tests used would detect levels as
low as 5 ppb.)
The first draw samples ta~en from the taps of selected customers
were well below the 1300 ppb ac~ion level for copper but some
exceeded ~~e 25 ppb action level lor lead. (The samples were at
189 ppb for copper and 29.8 ppb for lead).
The homes that exceeded the lead action level were resampled~ A
first draw sample was taken l and an additional sample was taken
after the water had run for 2 minutes. Although most of the
first draw &les sho~ed various levels of lead, all of the
second samples had non-detectable lead levels~ This re6ult
suggests the fol1o~ing actions be ta~en by individual hDmeowne~s
who are concerned 3bout an increase in water lead levels from
plumloing.
1. Testing;
Palo Alto
staff and
The water delivereQ to custo~ers by the City of
Water Utility has no problem. Due to the size of
funding, the Utilities Department is unable to
..
• \
J
I
test every homeowner's ~ater supply at their taps. For
custo~ers who would like to have their ~ater tested, the
attached list has the na:,.nes of laboratories .. ho will perform
such tests for a fee~
Precautions; It is fairly easy to avoid the extra lead in
standing water by just running a faucet for a minute or two
before drinking the water. The key times to do this are
first thing in the morning, or when arriving home after a
day when no one has beer. in the house. {Taking a shower
before drinking or cooking ~ater is an easy way to handle
the problem, for example.) Such water can be collected for
plant ~atering or other non-potable .. ater uses if a
homeowner chooses.
3. Brass Fixtures: One option is simply to replace these
fixtures with ones made of other material~. Otherwise,
following the prec~utions above should handle the problem.
ctrlt.Rllf]' B Tnv"TICN
Since the customer tap samples exceeded the action level for
lead, Palo Alto is require~ by the EPA to provide public
notification and education. CUrrently, we are working with the
Bay Area water Users Association to determine the most effective
way to notify the regional media. However, in the near term,
staff will be including information ~ith November utilities bills
and placing a notice in the f2.1.Q. Alt.o Weekly.
Palo Alto is also a member of the Santa Clara Valley Water
District's Joint Corrosion Control project. The purpose of this
project is to fulfill the EPA's Lead and Copper Rule's corrosion
testing requirements and to evaluate the various corrosion
control treatments on the different Santa Clara county source
waters in orQer to determine the optimal corrosion control
treatment for each source.
Kenned.y Jenks Consultants has performed an e)(tensive revie· ... of
water quality data from both surface and ground water sources
supplying Santa Clara County. Similar water sources ~ere grouped
and seven pipe loop station locations ~ere identified. At each
pipe loop station l four pipe loops ~ ... ill be installed to ·test
three corrosion control treatments and the fourth loop will test
only Hetch-Hetchy corrosion levels. The three corrosion control
treatmer.ts were selected after completing bench scale tests. All
pipe loops are scheduled to be operational by November 1992.
Each of the pipe loop stations will be operated for eight months
and will be monitored ~eekly.
All of Palo Alto's water comes from the San Francisco Water
• -..
'.; ......
\ .. ,
-_.----
'-;
,
1
! • .:; , , oep~rtment~ A pipe loop station will be inst~lled to monitcr
thia supply_ The infol~ation gained from this station will help
Palo Al to evaluate various alterna't:ives to reduce the
corro8ive~ess of our water supply.
In response to new Federal requirements, samples of water froQ
the City's dist~ibution system as _ell as samples from selected
resid-ential taps were tested for copper arId lead content. The
homes used for sampling were specifically selected because their
lead soldered plumbing was likely to increase water lead levels~
No detectable level~ of either lead or coppeL were found in the
City's distribution system. HoW'e~er, roughly ten percent of the
r~sidents samples exceeded the Federal -action level for lead"~
As a result, the city will be carl~ing cut a public notification
campaign to inform homeowners of the potential problem and
suggest ~it1qating action.
Th6 city i& participating in Santa Clara Valley Water District's
jOint project nov underwey to research and resolve the issue of
water corrosiveness causing increased lead and copper levels.
Respectfully submitted,
k"~J'J. v'",,='-' "--, "
RODGER JEN$EN, Manager,
Water-Gee-wastewater
Field Operations
/1 . ' 7' /',/i,<" ,,,.,,~ 4-c lea h,,:'~ ,71, / /
Rr.bIARo L. YOUN ,,/
O~ector, Uti ~ttes \ '
;./
/\J-<~pj/~
CKIt, 481, 92
, ,
DRINKING WATER lESTING IABORATORIES·
Anamctrix, Inc.
San!ose
(408) 432-8192
Applied Remediation Emirorunental Lab
San Jose
(408) 453·0501
AquaIab, Inc.
Santa Clara
(408) 492-1946
Columbia Analyti<;a! SeM=
San Jose
(4(8) 437-2400
Sequoia Analytical
Redwood City
(415) 364-9600
•
. ...,