2001-05-14 City Council (5)
City of, Pala A!to City Manager’s TO: FROM: DATE: SUBJECT: HONORABLE CITY COUNCIL CITY MANAGER MAY 14, 2001 DEPARTMENT: UTILITIES CMR:235:01 APPROVAL OF AN AWARD OF CONTRACT IN THE AMOUNT OF $710,144 TO ENERGY MASTERS INTERNATIONAL, INC. TO REDUCE ELECTRIC DEMAND IN CITY-OWNED FACILITIES RECOMMENDATION Staff recommends that Council: 1. Approve and authorize the Mayor to execute the attached contract with Energy Masters International, Inc. in the amount of $710,144 to expedite retrofits of electrical lighting systems to achieve demand reductions in 60 municipal facilities. 2.Authorize the City Manager or his designee to negotiate and execute one or more change orders with Energy Masters International, Inc. for related, additional but unforeseen work, which may develop during the project, the total value of which shall not exceed $71,020. BACKGROUND The State of Califomia is experiencing a severe energy crisis that will result in "rolling blackouts" this summer. Palo Alto is not immune to either the possibility of rolling blackouts this summer, or to the recent upward explosion in wholesale electricity prices. While new power plants are under construction, it is widely recognized that conservation and efficiency are the most potent approaches currently available to residences and businesses. On April 17, 2001, Council approved a $5 million Accelerated Energy Efficiency Program (AEEP) for the express purpose of expediting electrical demand reductions during the summer cooling season (CMR: 199:01). The City of Palo Alto Utilities Department is making every effort to implement AEEP with electric customers to achieve load reductions and efficiency improvements. Due to its size and consumption, the City of Pal0 Alto is a key account customer of the Utilities Department and, like other customers, can qualify for AEEP rebates. CMR: 235:01 Page 1 of 4 DISCUSSION Project Description Energy Masters International, Inc, was retained by the City of Palo Alto Utilities to provide a "fast-track" assessment and evaluation of lighting systems in City-owned buildingS. They completed a lighting audit of City facilities on an expedited basis and the results show that significant load and energy savings are available by upgrading lighting not only within the City Hall, but in most City facilities. The lighting retrofit proposal for Palo Alto municipal buildings is estimated to save approximately 1.5 million kilowatt-hours annually and 400 kilowatts in peak demand. Achieving this load reduction represents 8 percent of the 5,000 kilowatt demand reduction goal under AEEP. This opportunity represents permanent cost savings to the City, enables the City to "lead by example", and responds to the immediate need to reduce the Palo Alto electric demand, in anticipation of the "rolling blackouts" forecasted for this summer. With CounCil approval, staff proposes to enter into a contract with Energy Masters International, Inc. to perform the lighting system retrofits in over 60 City facilities, including Community Services buildings, Municipal Service Center buildings, parks and libraries. Replacing inefficient lighting with more efficient sources will reduce electric demand during the peak hours of the day when the buildings are occupied. The City has a role in achieving this reduction, as a major customer of the Utilities. Even more, the City of Palo Alto needs to set an example for other major customers and businesses in achieving significant energy reductions. Energy Masters International, Inc. will provide a turnkey project including design and engineering of lighting systems, project management and oversight, procurement of efficient environmentally friendly alternative lamps and fixtures, and recycling and disposal of existing lamps within 90 days of contract execution. It will bid all construction services to be performed under the City purchasing guidelines. Energy Masters International, Inc. will work closely with City staff to review bids and select the most qualified and economic subcohtractors to install the lighting retrofits. It will manage the selected subcontractors and will provide system commissioning for all installed fixtures. Energy Masters International, Inc. will also assume the performance risk of the project, and will protect the City from contractor change orders. Selection Process Staff recommends Council approval to enter into a contract with Energy Masters CMR: 235:01 Page 2 of 4 Masters International, Inc. to perform the lighting system retrofits for City facilities on an expedited basis without competitive bidding. The City Manager is invoking his authority under Municipal .Code Section 230.140 (a)(2) "where calling for bids on a competitive basis_ is impracticable, unavailing or impossible," The Utilities Department has ascertained that other qualified candidates to do this work are unavailable at this time, making it impractical to complete the work within the proposed timeframe. A competitive bidding process for this project would take a minimum, three months because the scope of services for 60 buildings is considerably detailed (attached)-and qualified energy contractors continue to be preoccupied with a worsening energy crisis. However, timing is important. The Utilities rebate program under AEEP is being dispersed to qualifying. customers on a first-come first-serve basis. There is no guarantee that funds will be available later this sums..__ er for the City’s project. AEEP funding represents a major source of funding for this project, funding that would otherwise have to come from the General Fund Budget Stabilization Reserve or Infrastructure Reserve~ A delay in implementing these efficiency measures in City facilities will cost the City in higher electric bills approximately $10,000 per summer month and cost the Electric Utility approximately $35,000 per summer month in net wholesale cost savings. Finally, it is also expected that bids received in the months ahead will continue to climb as the energy crisis adds an unpredictable variable that may result in severe shortages for qualified labor and materials. Price hikes for lighting fixtures and ballasts in short supply are presently being indicated by some manufacturers. Selection was based on the following criteria: overall .qualifications, experience in engineering, project management capability, familiarity with the 60 City facilities and systems it has previously audited, and the ability to offer competitiveproducts and services. on a fast track. Energy Masters International, Inc. is a nationally recognized energy-services provider which specializes in "design and build" engineering for energy-efficiency projects. It is currently under contract with the City of Palo Alto for: 1) a traffic signal system LED rrtrofit, and 2) providing Utilities Department key account Customers with efficiency audits and design/build construction projects. The staff has reviewed the EMI cost proposal and determined that the costs for labor, materials, and markup are reasonable given the prevailing wages for qualified labor, current prices for lighting fixtures, and the risks assumed by EMI RESOURCE IMPACT Under existing programs such as AEEP and "Commercial Advantage", Utilities will be contributing an efficiency rebate of approximately $249,033 towards the overall project cost of $710,144. A contract contingency fund in.the amount of $71,020 will be available for unforeseen circumstances or modifications to meet special user needs. The City of Palo Alto will be responsible for the $461,11 l(not including the contingency amount of $71,020) residual cost of the projectthat is not covered by the rebate. The retrofit CMR: 235:01 Page 3 of 4 will lower the City’s annual electricity bill by approximately $109,625. There will also be an additional maintenance savings of $8,000 annually. To expedite the project, the City’s portion of the project will be initially funded by AEEP. This amount will subsequently be. repaid.through State of California efficiency grants for municipal-governments, low interest State efficiency loans, or as a loan from the Utilities, with interest. Staff believes this approach to funding is appropriate for a pilot project to determine the internal processing methodology and systems required for similar loans to the key account market sector. POLICY IMPLICATIONS This award does not represent any change to existing City policies. ENVIRONMENTAL REVIEW This project is categorically exempt from California Environmental Quality Act and no further environmental review is necessary. ATTACHMENTS A: Contract with Energy Masters __International, Inc. B: Lighting Audit Su~mmary for Palo Alto MunicipalBuildings PREPARED BY: DEPARTMENT HEAD: Tom Auzenne, Mgr. Utility Marketing Services JOI~ ULRICH V " Director of Utilities CITY MANAGER APPROVAL: Assistant City Manager CMR: 235:01 Page 4 of 4 CONTRACT NO. BETWEEN THE CITY OF PALO ALTO AND ENERGY MASTERS INTERNATIONAL, INC. FOR DESIGN AND ENGINEERINGSERVICES TO REDUCE ELECTRICAL DEMAND IN CITY-OWNED FACILITIES This Contract No. is entered into , by and between the CITY OF PALO ALTO, a chartered, city and a municipal corporatibn of the State of California ("CITY"), and ENERGY MASTERS INTERNATIONAL, INC., a Minnesota corporation, located at 1385 Mendota Heights Road, St. Paul, MN 55120-1129 ("CONTRACTOR"). RECITALS~ WHEREAS, CITY desires certain design and engineering (~fast track" assessment and evaluations and retrofit of City facilities lighting systems) services ("Services"), as more fully described in Exhibit ~A"; and WHEREAS, CiTY desires to engage CONTRACTOR, including its employees, if any, in providing.the Services by reason of its qualifications and experience in performing such Services, and CONTRACTOR has offered to provide the Services on the terms and in the manner set forth herein; .. NOW, THEREFORE, in consideration of the covenants, terms, conditions, and provisions of this Contract, the parties agree: SECTION 1 - TERM i.i This Contract will commence on the date of its execution by CITY. The obligation of CONTRACTOR to perform the Services will commence in accordance with the time schedule set forth in Exhibit "B". Time is of the essence of this Contract. In the event that the Services are not completed within the specified time schedule on account of CONTRACTOR’s default, .CITY’s city manager willhave the option of extending the time schedule for any period of time. This provision will not preclude the recovery of damages for delay caused by CONTRACTOR. SECTION 2 - QUALIFICATIONS, CONTRACTOR STATUS,AND DUTIES OF 2.1 CONTRACTOR represents and warrants that it has the expertise and professional qualifications to furnish or cause to be furnished the Services. CONTRACTOR further represents and warrants that the project, director and every individual charged with the performance of the Services under this Contract are duly licensed 010510 sdl 0052714 1 or certified by the State of California, to the extent such licensing or certification is required by law to perform the Services. 2.2 In reliance on the representation and warranty set forth in Section 2.1, CITY hires CONTRACTOR to perform, and CONTRACTOR covenants and agrees that it will furnish or cause to be furnished, the Services. 2.3 CONTRACTOR will assign MITCH ANDERSON_as the project director to have supervisory responsibilit,y for the performance, progress, and execution of the Services. If circumstances or conditions subsequent to the execution of this Contract cause the substitution of the project director for any reason, the appointment of a substitute project director will be subject to the prior written approval of the project manager. 2.4 CONTRACTOR represents and warrants that it will: 2.4.1 Procure all permits and licenses, pay all charges and fees, and give all notices which may be necessary and incident to the due and lawful prosecution of the Services; 2.4.2 Keep itself fully informed of all existing and future Federal, State.of California, and local laws, ordinances, regulations, orders, and decrees which may affect, those engaged or employed under this Contract, any materials used in CONTRACTOR’s performance under this Contract, or the performance of the Services; 2.4.3 At all times observe and comply with, and cause its employees and contractors (and consultants), if any, who are assigned to the performance of this Contract to observe and comply with, the laws, ordinances, regulations, orders and decrees mentioned above; and 2.4.4 ... Will report in~nediately to the project manager, in writing, any discrepancy or inconsistency it discovers in the laws, ordinances, regulations, orders, and decrees mentioned above in relation to any plans, drawings, specifications or provisions of this Contract. 2.5 Any reports, information, data or other material given to, or prepared or assembled by, CONTRACTOR or its contractors, if any, under this Contract will become the Property of CITY and will not be made available to any individual or organization by CONTRACTOR or its contractors, if any, without the prior written approval of the city manager. 2.6 CONTRACTOR will provide CITY with three (3) hard copies and one (i) electronic copy of the final report which may be 010510 sdl 0052714 2 required under this Contract, upon completion and acceptance of each report by CITY. 2.7 If CITY requests additional copies of reports, drawings, specifications or any other material which CONTRACTOR is required to furnish in limited quantities in the performance of the Services, CONTRACTOR will provide such additional copies and CITY will compensate CONTRACTOR for its duplication costs. 2.8 CONTRACTOR will be responsible for_ employing or engaging all persons necessary to perform the Services. All contractors of CONTRACTOR will be deemed to be directly controlled and supervised by CONTRACTOR, which will be responsible for their performance. If any emplQyee or contractor of CONTRACTOR fails or refuses to carry out the provisions of this Contract or appears to be incompetent or to act in a disorderly or improper manner, the employee or contractor will be discharged immediately from further performance under this Contract on demand of the. project manager. SECTION 3 -DUTIES OF CITY 3..1 CITY will furnish or.cause to be furnished the specified services set forth in Exhibit ~A" and such other information regarding its requirements as may be reasonably requested by CONTRACTOR. 3.2 The city manager will represent CITY for all purposes under this Contract. VIRGINIA WAIK is designated as the project manager for the city manager. The project manager will supervise the performance, progress, and execution of the Services. 3.3 If CITY observes or otherwise becomes aware of any default in the performance of CONTRACTOR, CITY will use reasonable efforts, to give written .notice thereof to CONTRACTOR in a timely manner. SECTION 4 -COMPENSATION 4.1 In consideration ~of the full performance of the Services by CONTRACTOR, CITY will pay CONTRACTOR a total sum not to exceed Seven Hundred Ten Thousand One Hundred Forty-Four Dollars ($710,144.00) payable within thirty (30) days of submission by CONTRACTOR of its itemized billings, in. triplicate, in accordance with the following fee schedule set forth in Exhibit "B". SECTION 5 -AUDITS 5.1 CONTRACTOR will permit CITY to audit, at any reasonable time during the term of this Contract and for three (3) years thereafter, CONTRACTOR’s records pertaining to matters covered by this Contract. CONTRACTOR further agrees to maintain 010510 sdl 0052714 and retain such records for at least three (3) years after the expiration orearlier termination of this Contract. SECTION 6 -INDEMNITY 6.1 CONTRACTOR agrees to protect, indemnify, defend and hold harmless CITY, its Council members, officers, employees and agents from any and all demands, claims,, or liability of any nature, including death or injury to any person, property damage or any other loss, caused by or arising out of CONTRACTOR’s, its officers’, agents’, subcontractors’ or employees’ negligent acts, errors, or omissions, or willful misconduct, or conduct for which applicable law may impose strict liability on CONTRACTOR in the performance.of or failure to perform its obligations under this Contract. SECTION 7 -WAIVERS 7.1 The waiver by either party of any breach or violation of any covenant, term, condition or provision of this Contract, or of the provisions of any ordinance or law, will not be deemed to be a waiver of any other term, covenant, condition, provisions, ordinance or law, or of any subsequent breach or violation of the same or of any other term, covenant, condition, provision, ordinance orlaw. The subsequent acceptance by either party of any fee or Other. money which may become due hereunder will not be deemed to be a waiver of any preceding breach or violation by the other party of any term, covenant, condition or provision of this Contract or of any applicable law or ordinance. 7.2 No payment,, partial payment, acceptance, or partial acceptance by CITY will operate as a waiver on the part of CITY of any of its rights under this Contract. SECTION 8 -INSURANCE 8.1 CONTRACTOR, at its sole cost and expense, will obtain and maintain, in full force and effect during the term of this Contract, the insurance coverage described in Exhibit "C", insuring not only CONTRACTOR and its contractors, if any, but also, with the exception of workers’ compensation, employer’s liability, and professional liability insurance, naming CITY as an additional insured concerning CONTRACTOR’s performance under this Contract. 8.2 All insurance coverage required hereunder will be provided through carriers with Best’s Key Rating Guide. ratings of A:VII or higher which are admitted to transact insurance business in the State of California. Any and all contractors of CONTRACTOR retained to perform Services under this Contract will obtain and maintain, in full force and effect during the term of this Ol0510 sdl 0052714 4 Contract,identical insurance coverage, naming CITY as an additional insured under such policies as required above. 8.3 Certificates of such insurance, preferably on the forms provided by CITY, will be filed with CITY concurrently with the execution of this Contract. The certificates will be subject to the approval of CITY’s risk manager and will contain an endorsement stating that the insurance is primary coverage and will not be.canceled or altered by the insurer, except after filing with CITY’s city clerk thirty (30) days’ prior written notice of such cancellation or alteration, and that the City of Palo Alto is named as an additional insured except in policies of workers’ compensation, employer’s liability, and professional liability insurance. Current certificates of such insurance will be kept on file at all times during the term of this Contract with the city clerk. -~ 8.4 The procuring of such required policy or policies of insurance will not be construed to limit CONTRACTOR’s liability hereunder nor to fulfill the indemnification provisions of this Contract. Notwithstanding the policy or policies of insurance, CONTRACTOR will be obligated for the full and total amount of any damage, injury, or loss caused by or directly arising as a result of the Services performed under this Contract, including such damage, injury, or loss arising after the Contract is terminated or the term has expired. SECTION 9 -WORKERS’ COMPENSATION 9.1 CONTRACTOR, by executing this Contract, certifies that it is aware of the provisions of the Labor Code of the State of California which require every employer to be insured against liability for workers’ compensation or to undertake self-insurance in accordance with the provisions of that Code, and certifies that it will comply with such provisions, as applicable, before commencing the performance of the Services. SECTION i0 - SERVICES TERMINATION OR SUSPENSION OF CONTRACT OR i0.i The city manager may suspend the performance of the Services, in whole or in part, or terminate this Contract, with or without cause, ~by giving thirty (30) days’ prior written notice thereof to CONTRACTOR. Upon receipt of such notice,. CONTRACTOR will immediately discontinue its performance of the Services. 10.2 CONTRACTOR may terminate this Contract or suspend ’its performance of the Services by giving thirty (30) days’ prior written notice thereof to CITY, but only in the event of a substantial failure of performance by CITY or in the event CITY 010510 sdl 0052714 indefinitely withholds or withdraws its request for the initiation or continuation of the Services to be performed. 10.3 Upon such suspension or termination by CITY, CONTRACTOR will be paid for the Services actually rendered to CITY on or before the effective date of suspension or termination; provided, however, if this Contract is suspended or terminated on account of a default by CONTRACTOR, CITY will be obligated to compensate CONTRACTOR only for that portion of the .Services which are of direct and immediate benefit to CITY, as such. determination may be made by the city manager acting in the reasonable exercise of her discretion. 10.4 Upon such suspension or termination, CONTRACTOR will deliver to the city manager immediately any and all copies of studies, sketches, drawings, computations, and other data, whether or not completed, prepared by CONTRACTOR or its contractors, if any, or given to CONTRACTOR or its contractors, if any, in connection with this Contract. Such materials will become the- property of CITY. 10.5 The failure of CITY to agree with CONTRACTOR’s independent findings, conclusions, or recommendations, if the same are called for under£his Contract, on the basis of differences in matters of judgment, will not be construed as a failure on the part of CONTRACTOR to fulfill its obligations, under this Contract. SECTION Ii -ASSIGNMENT ii.I This Contract is for the personal services of .CONTRACTOR, therefore, CONTRACTOR will not assign, transfer, convey, or otherwise dispose of this Contract or any right, title or interest in or to the same or any part thereof without the prior ¯ written consent of CITY. A consent to one assignment~will not be deemed to be a consent to any subsequent assignment. Any assignment made without the approval of the city manager will be void and, at the option of the city manager, this Contract may be terminated. This Contract will not be assignable by operation of law. SECTION 12 -NOTICES 12.1 All notices hereunder will be given in writing and mailed, postage prepaid, by certified mail, addressed as follows: To CITY:Office of the City Clerk City of Palo Alto Post Office Box 10250 Palo Alto, CA 94303 010510 sdl 0052714 To CONTRACTOR: Attention of the project director at .the address of CONTRACTOR recited above SECTION 13 -CONFLICT OF INTEREST 13.1 In accepting this Contract, CONTRACTOR covenants that it presently has no interest, and will not acquire any interest, direct or indirect, financial or otherwise, which would conflict in any manner or degree with the perfQ~mance of the Services. 13.2 CONTRACTOR further covenants that, in the performance of this Contract, it will not employ anycontractoror person having such an interest. CONTRACTOR certifies that no person who_ .has or will have any financial interest under this Contract is an officer or employee of CITY; this provision will be interpreted in accordance with the applicable provisions of the Palo Alto Municipal Code and the Government Code of the State of California. SECTION 14 -NONDISCRIMINATION 14.1 As set forth in the Palo Alto Municipal Code, no discrimination will be made in the employment .of any person under this Contract because of the age, race, color, national origin, ancestry, religion, disability, .sexual preference or gender of that person. If the value of this Contract is, or may be, five thousand dollars ($5,000) or more, CONTRACTOR agrees to meet all requirements of the Palo Alto Municipal Code pertaining to nondiscrimination in employment, includingcompleting the requisite form furnished by CITY and set forth in Exhibit "D". 14.2 CONTRACTOR agrees that each contract for services with an independent provider will contain a. provision substantially as follows: "[Name of Provider] will provide CONTRACTOR with a certificate stating that [Name of Provider] is currently in compliance with all Federal and State of California laws covering nondiscrimination in employment; and that [Name of Provider] will not discriminate in the employment of any person under this Contract because of the age, race, color, national origin, ancestry, religion, disability, sexual, preference or gender of such person." 14.3 If CONTRACTOR is found in violation of the nondiscrimination provisions of the State of California Fair 0105 I0 sdl 0052714 7 Employment Practices Act or similar provisions of Federal law or executive order in the performance of this Contract, it will be in default of this Contract. Thereupon, CITY will have the-power to cancel or suspend this Contract, in whole or in part, or to deduct the sum of twenty-five dollars ($25) for each person for each calendar day during which such person was subjected to acts of discrimination, as damages for breach of contract, or both. Only a finding of the State of California Fair Employment Practices Commission or the equivalent federal agency or officer will constitute evidence of a breach Of this Contract. .r SECTION 15 -MISCELLANEOUS PROVISIONS 15.1 CONTRACTOR represents and warrants that it has knowledge of the requirements-of the Americans with Disabilities Act of 1990, and the Government Code and the Health and Safety Code of the State of California, relating to access to public buildings and accommodations for disabled persons, and relating to facilities for disabled persons. CONTRACTOR will comply with or ensure by its advice that compliance with such provisions will be effected in the performance of this Contract. 15.2 This Contract will be governed by the laws of the State of California, excluding its-conflicts of law. 15.3 In the event that an action is brought, the parties agree that trial of such action will be vested exclusively in the state courts of California or in the United States District Court for the Northern District of California in the County of Santa Clara, State of California. 15.4 The prevailing party in any action brought to enforce the provisions of this Contract may recover its reasonable costs and attorneys’ fees expended in connection with that action. 15.5 This document represents, the entire and integrated agreement between the parties and supersedes all prior negotia- tions, representations, andcontracts, either written or oral. This document may be amended only .by a written instrumenh, which is signed by the parties. 15.6 All provisions of this Contract, whether covenants or conditions, will be deemed to be both covenants and conditions. 15.7 The covenants, terms, conditions and provisions of this Contract will apply to, and will bind, the heirs, successors, executors, administrators,.assignees, and contractors, as the case may be, of the parties. 15.8 If a court of competent jurisdiction finds or rules ¯ that any provision of this Contract or any amendment thereto is 010510 sdl 0052714 8 void or unenforceable; the unaffected provisions of this Contract and any amendments thereto will remain in full force and effect. 15.9 All exhibits referred to in this Contract and any addenda, appendices, attachments, and schedules which, from time to time, may be referred to in any duly executed amendment hereto are by. such reference incorporated in this Contract and will be deemed to be a part of this Contract. 15.-10 This Contract may be executed in .any number of counterparts, each of which will be an original, but all of which together will constitute one and the same instrument. 15.11 This Contract is subject to the fiscal provisions of the Charter of the City of Palo Alto and the Palo Alto Municipal Code. This Contract will terminate without any penalty (a) at the end of any fiscal year in the event that funds are not appropriated for the following fiscal year, or (b) at any time within a fiscal year in the event that funds are only appropriated for a portion of the fiscal year and funds for this Contract are no longer available. This Section 15.11 shall take precedence in the event of a conflict with any other covenant, term, condition, or provision of this Contract. ~ // II II // // // // // // // // // // 010510 sdl 0052714 9 IN WITNESS WHEREOF, the parties hereto have by their duly authorized representatives executed this Contract on the date first above written. ATTEST:CITY OF PALO ALTO City Clerk APPROVED AS TO FORM: Senior Asst. City Attorney APPROVED: Assistant City Manager Director of Administrative Services Director of Utilities Risk Manager Mayor ENERGY.MASTERS INTERNATIONAL, INC. By: Name: Title: By: Name: Title: Taxpayer Identification No. Attachments : EXHIBIT "A" : EXHIBIT "B" : EXHIBIT "C" : EXHIBIT "D" : (Compliance with Corp. Code § 313 is required if the entity on whose behalf this contract is signed is a corporation. In the alternative, a certified corporate resolution, attesting to the signatory authority of the individuals signing in their respective capacities is acceptable) SCOPEOF PROJECT RATE & TIME SCHEDULE INSURANCE NONDISCRIMINATION COMPLIANCE FORM i0 010510 sd10052714 CERTIFICATE OF ACKNOWLEDGEMENT (Civil Code §. 1189) STATE OF ) ) SS. COUNTY OF ) On , 2001, before me,, a Notary Public in and for said County and State, personally appeared , personally known to me or proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/sheJthey executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. Signature of Notary Public ii 010510 sdi~52714 CERTIFICATE OF ACKNOWLEDGEMENT (Civil Code § 1189) STATE OF ) ) SSo COUNTY OF ) On , 2001, before me,, a Notary. Public in and for said County and State, personally appeared , personally known to me or proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknow£edged to me that .he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. Signature of Notary Public 0105 IO.sdl 0052714 12 Exhibit A SCOPE OF PROJECT & TIME SCHEDULE ATTACHMENT A SPACE-BY-SPACE SCOPE OF WORK ATTACHMENT B SCHEDULE & PAYMENT Correspondence Correspondence concerning all aspects of this contract shall be directed to: Project Mana,qer: Mitch Anderson Phone: (916) 325-5503 Energy Masters International, Inc. River Park Business Center 444 North 3r~ Street Suite 104 Sacramento, CA. 95814 Scope of Services Provide all labor, material and professional services for complete design/build implementation of the Fast Track Lighting Efficiency Upgrades, installed per local and national Codes as follows: En.~ineerin~ Desi.qn of the recommended lighting retrofit includes: ¯Pre-qualify contractors. ¯Audit all facilities and make appropriate recommendations. ¯Retrofits will maintain or improve existing light levels except where existing levels are too high. ¯Specify low mercury linear fluorescent lamps. ¯Conduct project walk-through for contractors. ¯Receive and evaluate construction and vendor pricing. ¯Negotiate contractor costs.and award of subcontracts. Construction Administration work assures correct installation in compliance with this scope of work and specifications. This includes: ¯Pre-construction meeting for City approval on materials and schedules. ¯Approve contractor installation plans. ¯Receive, accept and document delivery of inventory. ¯Ensure product adherence to specification. ¯Conduct regular construction coordination meetings to review construction and progress. ¯Perform regular site visits and investigate progress. ¯Review contractor progress payment requests and submit to City for approval. . ¯Frequently report to the City on construction status and milestones. ¯Assemble final punch list and project approval. Post-construction Services assures that all new and renovated equipment and systems are properly installed .and commissioned and-that the City’s personnel are properly trained on the operation, maintenance, and purpose of this equipment as well as on energy efficient practices. It also includes the cost to measure and verify energy savings, as required by the Utility. ¯Confirm proper operating conditions are maintained. ¯Conduct training for appropriate City personnel, if applicable. ¯Conduct all savings measurement and verification, in concert with the Utility. ¯Prepare and deliver a summary report of results with evaluation to the City. ¯Warranty includes labor and materials of all installed equipment for one year. ¯Material warranty includes three (3) years on lamps and five (5) years on ballasts. ¯All storage, disposal, recycling costs are included as part of the Scope. ¯All permits and fees are included. ¯" The manufacturer’s warranty will cover materials for three years on lamps and five years on ballasts. Payment and Performance Bonds We will procure Payment and Performance Bonds as required by the City. Payment and Performance bonds are typically written for the installed cost of labor and material based on declining block coverage. The total cost for bonds are based on the total installed cost of the project. This normally equates to approximately 1% of Labor and Material contract value. Program Management Fee covers the overall management and administration of the project. It is analogous to the services of a Developer/General Contractor and includes the following: ¯Coordination, management and scheduling of all subcontractors and services. ¯Arrangement and coordination of program financing. ¯Coordination of utility resources or incentives, where applicable ¯Legal and contractual program management. ¯General and administrative overhead. ¯Risk This program management fee also incorporates our performance risk. It is EMI’s responsibility to assure that a quality program is implemented within budget and that savings are generated, verified, and maintained such that they will cover all Program Costs. We take responsibility for accurate inventories of systems to be installed. Any fixtures not captured in our assessments will be installed at no cost to the C!ty. Quantities & Locations See Attachment "A" for the specific building and space-by-space recommendations. Schedule, Price and Payment Terms See Attachment "B" for the schedule, price and payment terms. ’Measurement & Verification Measurement and verification of the actual savings will be performed by stipulated and measured savings: ¯Hours of operation will be agreed to by the City. ¯Random measurements (amps, volts and power) readings will be’performed to verify the wattages used to calculate savings pre- and post-installation. When a reasonable comfort level is reached by the City, these wattages will be used to stipulate the savings calculations. ¯A summary report will be generated documenting the actual savings. Illumination Levels ¯Foot-candle readings will be taken pre- and post-installation on all occupied spaces... ¯Spaces with similar dimensions, fixture types and counts will be treated as typical. ¯A report will be generated documenting pre- and post-construction lighting levels. Extended Warranty Manufacturer’s warranty on material will be three (3) years on lamps and five (5) years on ballasts. Energy Masters International will provide one (1) year warranty on labor. The extended warranty will include the following: ¯Lamp and ballast stock for emergency replacements. ¯Up to twelve (12) warranty site visits. ¯City will provide punch list items for warranty replacement. ¯Maximum two (2) days pervisit. Trainincl Energy Masters International and/or their subcontractors will provide up to four (4) hours of training for City operations and maintenance personnel. The content and location of the training session will be mutually determined by Energy Masters International and the City to maximize the effectiveness of the training. Public Documents All documents will become the property of the City of Palo Alto. ATTACHMENT "A" SPACE-BY-SPACE SCOPE OF WORK Animal Services - 3281 E. Bayshore Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 entry 6 3’x3’ 3L sm box 2 entry 12 2’x4’ 3L 3 Hall 1. " Inc. 1L rec Square 4 Storage 1 l’x4’x 2L wp 5 - Vet Service Room 8 l’x4’x 2L sm strip 6 Exam Room 3 l’x4’x 2L wp 7 Office 2 2’x4’3L 8 Break Room 6 2’x2’ 2L sm 9 Office 2 2’x2’ 2L sm 10 Cat’s Hall 4 Inc. 1L Jar 11 Room#1 .3 l’x4’x2Lwp ¯ 12 Room #2 3 l’x4’x2Lwp 13 Women’s Restmom 1 l’x4’x 2L wp 14 Men’s Restroom 1 2’x4’ 4L sm wp 15 Equipment Room 0 No Access 28 Front Canopy 9 Inc. 1L sm Square 62 Lamp Lamp Type Hours 3 F30T12 4000 3 F40T12 34w 4000 1 Inc. 100w 4000 2 F40T12 34w 800 2 F40T12 34w 3120 2 F40T12 34w 3120 3 F40T12 34w 3120 2 FB40T12 3120 2 FB40T12 3120 1 Inc. 100w 4000 2 F40T12 34w 4000 2 F40T12 34w 4000 2 F40T12 34w 2500 4 F40T12 34w 2500 0 n/a 800 1 Inc. 100w 4368 Proposed Conditions Qty Retrofit Description 6 (3) F25T lamps, (1) 3L Ip elect bllst 12 (3) F32T8 lamp, (1) 2L Ip elect bllst 1 (1) CF 22w lamp and ballast 1 (2) F32T8 lamp, (1)2L nl elect bllst 8 (2) F32T8 lamp, (.5) 4L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (3) F32T8 lamp, (1)2L Ip elect bllst 6 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 4 DND (items left as!s) 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 0 DND (items left as is) 9 (1) CF 22w lamp and ballast 62 Energy Masters Intemational Page 1 City of Palo Alto Animal Services Euthanasia - 3281 E. Bayshore Road, Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 20 Euthanasia Building 4 l’x4’x 2Lwp 2 4 Lamp. Type F40T12 34w Hours 1500 4 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Animal Services Kennels - 3281 E. Bayshore Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Descr!ption Lamp Main Building - 1st Floor 16 Kitchen 2 Inc. 1LrecSquare 17 Kitchen 3 2’x4’ 4L sm wp 18 Storage 2 2’x4’ 4L sm wp 19 Hall 1 l’x4’x 2L sm strip 21 Isolation 4 l’x4’x 2L wp 22 Isolation 2 2’x4’ 4L sm wp 23 Dogs 3 Inc. 1L rec Square 24 Dogs 10 l’x4’x2Lwp 25 Exterior Hall 3 Inc. 1L sm Square 26 Exterior Hall 3 Inc. 2L dome 27 Exterior !__0 Inc. 1LsmSquare 43 1 4 4 2 2 4 1 2 1 2 1 Lamp Type Inc. 100w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc. 100w F40T12 34w Inc. 100w Inc. 60w Inc. 100w Hours 2500 2500 8O0 1500 800 800 4000 4000 4368 4368 4368 Proposed Conditions Qty Retrofit Description 2 (1) CF 22w lamp and ballast 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 3 (1) CF 22w lamp and ballast 10 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (1) CF 22w lamp and ballast 3 New sm drum with (2) CF 15 watt lamps and ballast 10 (1) CF 22w lamp and ballast 43 Energy Masters International Page 1 City of Palo Alto Arasta Rangers Quarters - Ref #Room # Main Building - 1st Floor 1 all areas ¯ Existing Conditions Description 0 dnd (site removed) 0 Lamp Lamp Type Hours 0 DND (items left as is) 0 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description Energy Masters International Page 1 City of Palo Alto Arasta Reserve Barn- Ref #Room # Main Building - 1st Floor 1 all areas Existing Conditions Qty Description 0 dnd (site removed) 0 Lamp Lamp Type n/a Hou~ DND (items left as is) RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description Energy Masters International Page 1 City of Palo Alto Bayland Athletic Center Restroom - 1785 Embarcadero Road RETROFIT SCOPE REPORT Existing Conditions Ref# Room# Qty Description Lamp Lamp Type Hours Qty Main Building - 1st Floor 1 Men’s Restroom - 2 F40T12 34w 8760 2 Women’s Restroom 2 F40T12 34w 8760 5 l’x4’x 2L Vapor 2 l’x4’x 2L Vapor 7- 5 2 Proposed Conditions Retrofit Description (2) F32T8 lamp, (.5) 4L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst " Energy Masters International Page 1 City of Palo Alto Baylands Interpretive Center- 2775 Embarcadero Road Existing Conditions Ref # Room # Qty Description Lamp Lamp Type Main Building - 1st Floor 1 open area 1 Inc. 1Ltrack 1 2.open area 1 CF 2L exit sign 2 3 Entry 4 Inc.2Ldome 2 4 Women’s Restmom 5 l’x4’x 1L sm wp 1 5 Men’s Restroom 5 l’x4’x 1L sm wp t 6 Office .5 l’x4’x 1L sm wp t 7 Office 14 l’x4’xlLsmwp 1 35 Inc. 75w par CF7w Inc. 60w F40T12 34w F40T12 34w F40T12 34w F~,0T12 34w Hours 1500 8760 1500 1500 1500 2000 2000 1 1 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 4 5 5 5 14 35 DND (items left as is) DND (items left as is) New sm dram with (2) CF 15 watt lamps and ballast (1) F32T8 lamp, (1) 1L Ipelect bllst (1) F32T8 lamp, (1) 1L Ip elect bllst (1) F32T8 lamp, (1) 1L Ip elect bllst (1) F32T8 lamp, (1) 1L Ip elect bllst Energy Masters International Page 1 City of Palo Alto Byxbee Park RR - 2380 Embarcadero Road Ref #Room # Main Building - 1st FlOor 1 RR Existing Conditions Qty Description 4 l’x4’x 2L sm wp 4 Lamp Lamp Type Hours Qty F40T12 34w 8760 4 J 4 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Children’s Library - 1305 Middlefield Road Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 Children’s Lab 15 Inc. 1L PM Globe 2 Hall 2 l’x4’x2Lsmwp 3 Work Room 1 Inc. 1L PM Globe 4 Non English 1 Inc. 1L PM Globe 5 Office #2 1 Inc. 1L PM Globe 6 Women’s Restmom 2 Inc. 1L dome 7 Break Room 2 l’x4’x 2L sm wp 8 Faculty Break 1 Inc. 1L dome 25 Lamp Lamp Type Hours City 1 Inc. 300w 3000 2 F40T!2 34w 3000 1 Inc. 300w 3000 1 Inc. 300w 3000 1 Inc. 300w 2500 1 Inc. 100w 1500 2 F40T12 34w -1500 1 Inc. 100w 1500 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 15 New l’x4’x 2L Wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 2 (2) F32.18 lamp, (1) 2L nl elect bllst 1 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 1 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ipelect bllst 1 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 2 (1) CF 22w lamp and ballast 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 22w lamp and ballast 25 Energy Masters International Page 1 City of Palo Alto Children’s Theatre - 1305 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Boy Scouts - 1st Floor 37 Lobby 1 Inc. 2L exit sign 38 Office 2 l’x4’x 2L sm hood 39 Office 3 1’x8’ 2L strip 40 Office 2 l’x2’x 1L stdp 41 Conference 12 Inc. 1L rec Can 42 Display 7 l’x3’x 1L sm stdp 43 Display 3 l’x4’x 1L stdp 44 Supplies 2 l’x4’x 2L sm hood 45 Men’s Restroom 1 Inc. 2L dome 46 Women’s Restroom 1 Inc. 2L dome 47 Office #1 , _3 1’x4’ 4L rec 48 Office #2 2 1’x4’ 4L rec, 49 Storage 1 l’x4’x 2L wp 50 Administration 3 1’x4’ 4L rec 51 Business Office 2 1’x4’ 4L hood MainBuilding - 1st Floor 1 Lobby,3 Inc. 3L PM prsm 2 Lobby 2 Inc. 1L rec Can 3 Office #1 2 Inc. 1L rec Can 4 Office #2 2 1’x4’ 4L sm wp 5 Office #3 3 l’x# 4L sm wp 6 Rehearshal Room 4 1’x4’ 4L sm wp 7 Kitchen 2 Inc. 2L dome 8 Library Studio :2 Inc. 1LrecCan 9 Library Studio 2 l’x4’x 2L rec 10 . Library Studio 1 LED exit sign 11 Halls 6 CF 12 Costume #1 2 1’x4’ 4L sm wp . 13 Costume #1 2 Inc. 1L dome 14 Costume #2 2 1’x4’ 4L sm wp 15 Costume #2 2 Inc. 1L dome 16 Workshop 4 1’x8’ 2L chn pm 17 Small Theatre 0 HID 18 Workshop Office 1 1’x4’ 4L sm wp 19 Workshop #2 5 1’x8’ 2L chn pm 20 Restroom 1 l’x4’x 2L rec 21 Extedor 4 Inc. 1L rec 22 Theatre Stage 5 l’x4’x 1L stdp 24 Theatre 4 Inc. 2L exit sign 25 Lobby Restroom 1 l’x4’x 2L rec 26 Lobby Restroom 1 Inc. 1L dome Energy Masters International Lamp Lamp Type Hours Qty 2 Inc. 20w 8760 2 F40T12 34w 2000 2 F96T1260w 2000 1 F20T1220w 2000 1 Inc. 100w 2000 1 F30T12 2500 1 F40T12 34w. 2500 2 F40T1234w 2000 2 Inc.60w 2000 2 Inc.60w 2000 4 F40T12 34w 2000 4 F40T12 34w 2000 2 F40T1234w 800 4 F40T12 34w 2000 4 F40T12 34w 2000 3 Inc. 100w 3000 1 Inc. 100w 3000 1 Inc. 100w 2500 4 F40T12 34w 2500 4 F40T12 34w 2500 4 F40T12 34w 2000 2 Inc. 60w 2000 1 Inc. 100w 1500 2 F40T1234w 1500 1 LED 1500 1 CF 15w 2000 4 F40T12 34w 800 1 Inc. 100w 800 4 F40T12 34w 800 1 Inc. 100w 800 2 F96T1260w 1500 1 HID 1500 4 F40T1234w 1500 2 F96T1260w 1500 2 F40T12 34w 1500 1 Inc. 100w 4380 1 F40T12 34w, 1500 2 Inc. 20w 8760 2 F40T12 34w 2000 1 Inc.60w 2000 Page 1 Proposed Conditions Retrofit Description 1 LED exit sign w/bait backup when needed 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit 2 (1) F17T8 lamp, (1) 1L Ipelect bllst 12 (1) CF 22w lamp and ballast 7 (1) F25T lamp, (1) 1L Ip elect bllst 3 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 New sm drum with (2) CF 15 watt lamps and ballast 1 New sm drum with (2) CF 15 watt lamps and ballast 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 3 (3) CF 28w lamp and ballast 2 (1) CF 22w lamp and ballast 2 (1) CF 22w lamp and ballast 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 4 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 New sm drum with (2) CF 15 watt lamps and ballast 2 (1) CF 22w lamp and ballast 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 DND (items left as is) 6 DND (items left as is) 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (1) CF 22w lamp and ballast 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (1) CF 22w lamp and ballast 4 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 0 DND (items left as is) 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 5 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit 1 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (1) CF 22w lamp and ballast 5 (1) F32T8 lamp, (1) 1L Ip elect bllst 4 LED exit sign w/balt backup when needed 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New sm drum with (2) CF 15 watt lamps and ballast City of Palo Alto Children’s Theatre- 1305 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp 2rid Floor 23 Control 3 l’x4’x 2L rec 2 Basement 27 Basement 7 l’x4’x 2L sm hood 2 28 Basement 1 1’x4’ 4L hood 4 29 Basement 1 1’x8’ 4L hood 4 30 Basement 1 Inc. lL 1 31 Accessory 1 1’x8’ 1L strip 1 32 Men’s Rack Room 1 l’x4’x 2L sm hood 2 33 Men’s Rack Room 3 1’x8’ 1L strip 1 34 Women’s Rack Room 1 l’x4’x 2L sm hood 2 35 Women’s Rack Room 3 1’x8’ 1L strip 1 36 aminal farm 3 1’x8’ 1L strip 1 133 Lamp Type F40T1234w F40T1234w F40T1234w F96T1260w Inc. 100w F96T1260w F40T1234w F96T1260w F40T1234w F96T1260w F96T1260w Hours City Proposed Conditions Retrofit Description 800 3 (2) F32T8 lamp, (1).2L nl elect bllst 2500 7 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 2500 1 (8) F32T8 lamp, (2) 4L Ip.elect bllst, (1) bracket kit, (1) ballast pan 2500 1 (1) CF 22w lamp and ballast 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) bracket kit 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 3 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) bracket kit 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 3 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) bracket kit 800 3 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) bracket kit 133 Energy Masters International Page 2 City of Palo Alto College Terrace Library - 2300 Wellesley Street Existing Conditions Ref # Room # Qty Description Lamp Childcare - 1st Floor 8 Community Info Entry 9 Men’s Restroom 10 Women’s Restroom 11 ’ Sleep Room 12 Kitchen 13 Day Care 14 Day Care 15 Restroom 16 Sleep Room Main Building - 1st Floor 1 2 3 4 5 6 7 Main Library Non Fiction Area Office Entrance Storage Restmom Kitchen 1 Inc. 1L dome 1 1 Inc. 1L dome 1 1 Inc. 1Ldome 1 1 1’x4’ 4L PM wp 4 5 Inc. 2L dome 2 4 1’x4’ 4L PM wp 4 4 Inc. 1Ldome 1 2 Inc. 2Ldome 2 1 1’x4’ 4L PM wp 4 28 1’x4’ 4L PM wp 4 12 l’x4’x 2L sm wp 2 2 l’x4’x 2L sm wp 2 1 l’x4’x 2L sm wp 2 1 1’x4’ 4L PM wp ~ 4 1 Inc. 1L 1 2 l’x4’x 2L sm wp 2 67 Lamp Type Inc. 60w Inc. 60w Inc. 60w F40T12 34w Inc. 60w F40T12 34w Inc. 60w Inc. 60w F40T12 34w F40T1234w F40T1234w F40T1234w F40T1234w F40T12 34w Inc. 100w F40T12 34w RETROFIT SCOPE REPORT Proposed Conditions Hours Qty Retrofit Description 800 1 New sm drum with (2) CF 15 watt lamps and ballast 800 1 New sm drum with (2) CF 15 watt lamps and ballast 800 1 New sm drum with (2) CF 15 watt lamps and ballast 800 1 (4) F32T8 lamp, (1) 4L Ipelect bllst 800 5 New sm drum with (2) CF 15 watt lamps and ballast 1900 4 (4) F32T8 lamp, (1) 4L Ip elect bllst 1900 4 New sm drum with (2) CF 15 watt lamps and ballast 1200 2 New sm drum with (2) CF 15 watt lamps and ballast 800 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 1900 28 (4) F32T8 lamp, (1) 4L Ip elect bllst 1900 12 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2200 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 800 1 (1) CF 22w lamp and ballast 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 67 Energy Masters International Page 1 City of Palo Alto community Theatre Scene Shop - 1305 Middlefield Road Ref #Room # Main Building - 1st Floor 62 Scene Shop Existing Conditions City Description Lamp Eamp Type 14 1’x8’ 3Lhood 3 F96T12 HO Hours 3000 14 14 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description New l’x8’x 8L wrap, w/(8) F32T8 lamps, (2) 4L Ip elect bllst Energy Masters International Page 1 City of Palo Alto Cubberley Community - 4000 Middlefield Road , RETROFIT SCOPE REPORT Existing Conditions Ref#Room#Qty Description Lamp Lamp Type Hours Building A - 1st Floor 158 A7 12 l’x4’x2Lsmwp 2 F40T1234w 3120 159 A6 12 l’x4’x2Lsmwp 2 F40T1234w 3120 160 A5 12 l’x4’x2Lsmwp 2 F40T1234w 3120 161 Mechanical 1 Inc. 1L 1 Inc. 100w 800 162 A4 12 l’x4’x2L~mwp 2 F40T1234w 3120 163 ¯ A4 Office 2 l’x4’x 2L sm wp 2 F40T12 34w 3120 164 A5 Office 2 l’x4’x 2L sm wp 2 F40T12 34w 3120 165 A3 12 l’x4’x 2L sm wp 2 F40T12 34w 3120 166 A2 12 l’x4’x2Lsmwp 2 F40T1234w 3120 167 A2Restmom 3 l’x4’x2Lsmwp 2 F40T1234w 1200 Building B ..... 1st Floor 168 B2Restmom 2 ¯ l’x4’x2Lsmwp 169 B2 12 l’x4’x2Lsmwp 170 B3 12 l’x4’x2Lsmwp 171 B4 12 l’x4’x2L-smwp 172 B4 Office 2 l’x4’x 2L sm wp 173 B5 Office 2 l’x4’x 2L sm wp 174 B5 12 l’x4’x2Lsmwp 175 B6 12 l’x4’x2Lsmwp 176 B7 8 l’x4’x 2L sm wp 177 B Women’s Restroom 2 l’x4’x 2L sm wp Building C - 1st Floor 178 C7 6 l’x4’x2Lsmwp 179 C6 6 l’x4’x2Lsmwp 180 Closet 1 Inc. 1L 181 C5 12 l’x4’x2LsmwP 182 C4 12 l’x4’x 2L sm wp 183 C3 12 l’x4’x2Lsmwp 184 . C2 21 l’x4’x 2L sm wp 185 C2 Office 2 2’x4’ 4L Building D - 1st Floor 186 D Restroom 2 l’x4’x 2L sm wp 187 D1 6 l’x4’x2Lsmwp 188 D2 6 l’x4’x2Lsmwp 189 D3 14 l’x4’x2Lsmwp 190 D4 8 l’x4’x 2L sm wp 191 D5 6 2’x4’4L 192 D6 6 2’x4’4L Energy Masters International 2 F40T12 34w 1200 2 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w ~3120 2 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w¯ 1200 2 F40T1234w 3120 2 F40T1234w 3120 1 Inc. 100w 800 2 F40T1234w 3120 2 F40T1234w 3120 2 F40T1234w 3120 2 F40T1234w 3120 4 F40T1234w 3120 2 F40T12 34w 1200 2 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w 3120 4 F40T1234w 3120 4 F40T1234w 3120 Page 1 Proposed Conditions Qty Retrofit Description 12 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 22w lamp and ballast 12 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 8 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 6"(2) F32T8 lamp, (.5) 4L nl elect bllst 6 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (1) CF 22w lamp and ballast 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 21 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (.5) 4L nl elect bllst 14 (2) F32T8 lamp, (.5) 4L nl elect bllst 8 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 6 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl City of Palo Alto Cubberley Community - 4000 Middlefield Road Existing Conditions Ref #Room #Qty Description 193 D7 6 l’x4’x2Lsmwp Building E - Lamp 2 1st Floor 194 E7 6 l’x4’x2Lsmwp 2 195 E6 6 l’x4’x2Lsmwp 2 196 E5CIoset t Inc. lL 1 197 E5 Office 2 l’x4’x 2L sm wp 2 198 E5 12 2’x4’4L 4 199 E4 12 2’x4’4L 4 200 Custodial 1 l’x4’x 2L sm wp 2 201 E3 6 l’x4’x 2L sm wp 2 202 E2 0 Dark Room- DND 0 203 E1 .6 l’x4’x 2L sm wp 2 204 FI 6 l’x4’x 2L sm wp .2 Building F - 1st Floor 205 F1Office 3 l’x4’x2Lsmwp 2 206 F2 3 l’x4’x 2L sm wp 2 207 F3 Artist Studio 6 l’x4’x2Lsmwp 2 208 F4 6 2’x4’4L 4 209 F5 6 l’x4’x2Lsmwp 2 210F6 3 Inc, lL 1 211 F7 12 l’x4’x2Lsmwp 2 212 FHOpenArea 1 2’x4’4L 4 213 FHOpenAma 3 2’x8’4Lsmbox 4 214 FH Storage 1 l’x4’x 2L sm wp 2 215 FH Office 1 1 2’x4’ 4L 4 216 FHOffice2 1 2’x8’4Lsmbox 4 217 FH Office 3 2 2’x8~ 4L sm box 4 218 FHHall 3 l’x4’x2Lsmwp 2 219 FH Restroom 1 l’x4’x2Lsmwp 2 Building H - 1st Floor 36 H1 9 2’x8’2L 2 37 H2 2 2’xS’2L 2 38 H3 Office 2 2’x8’ 2L 2 39 H3 6 2’x8’2L 2 40 H3 Kitchen 2 2’x8’ 2L 2 41 H3 Office 2 2 2’x8’ 2L 2 42 H4A 8 2’xS’2L 2 43 H5 4 2’x4’ 4L rec prsm 4 44 H5 4 2’xS’2L 2 45 H6 12 2’x8’ 2L sm box 2 Lamp Type F40T12 34w F40T12 34w F40T12 34w Inc. 300w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w n/a F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc, 300w F40T12 34w F40T12 34w F96T12 60w F40T12 34w F40T12 34w F96T12 60w F96T12 60w F40T1234w F40T12 34w F96T1260w F96T1260w F96T1260w F96T1260w F96T1260w F96T1260w F96T1260w F40T12 34w F96T1260w F96T12 60w Hours Qty 3120 , 6 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst 3120 6 (2) F32T8 lamp, (1) 2L.nl elect bllst 3120 6 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 New 1’)~4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 3120 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 12 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 12 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 6 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 0 DND (items left as is) 3120 6 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 6 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 6 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 6 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 6 (2)~F32T8 lamp, (1) 2L nl elect bllst 3120 3 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 3120 12 (2) F32T8 lamp, (1).2L nl elect bllst 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 3 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 1 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 2 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 9 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 2 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 2 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 6 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 2 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 2 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 8 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 4 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3120 12 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan Energy Masters Intemational Page 2 City of Palo Alto Cubberley Community - 4000 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp 8 2’x8’ 2L sm box 2 4 2’x4’ 4L sm box 4 2 2’x4’x 2L sm box 2 1 2’x4’x 2L sm box 2 ¯ 46 H5 47 H5 48 H5 Hallway 49 H5 Closet Building I - 1st Floor¯127 College Admin 128 College Admin 129 College Admin 130 College Admin 131 " College Admin 132 College Kitchen 133 College Computer 134 College Lab Hall 135 College Lab Hall 136 Office 137 14 138 15 139 16 140 I Break Room 141 13 142 13 143 12 144 12 Storage 145 12 Storage 146 I1 147 I1 148 110 149 IA Lecture Hall 150 IA Lecture Hall 151 IA Lecture Hall Room 152 I Hall 153 I Hall 154 I Electrical Room 155 I Janitor 156 I Hall 157 1 Hall Building J - 1st Floor 114 J Women’s Restroom 1t5 J Men’s Restroom 116 J2 117 J1 118 J2 Office 1 38 .2’x4’x 2L sm 2 2’x4’x 2L sm 2 2’x4’x 2L sm 2 2’x4’x 2L sm 2 2’x4’x 2L sm. 4 2’x4’x 2L sm ~!_3_ 1 l’x4’x 1L sm wp 4 l’x4’x 2L sm wp 3 Inc. 2L exit sign 1 l’x4’x 2L sm wp 42 - l’x4’x IL sm wp 54 l’x4’x 1L sm wp 12 l’x4’x 2L sm wp 15 l’x4’x 2L sm wp 80 l’x4’x 1L sm wp 2 Inc. 2L exit sign 80 l’x4’x 1L sm wp 33 l’x4’x 1L sm wp 4 l’x2’x 1L 24 l’x4’x 1L sm wp 4 l’x2’x 1L 12 l’x4’x 1L sm wp 20 4’x4’ 6L 4 Inc. 2L exit sign 4 2’x4’x 2L sm 2 2’x4’x 2L sm Inc. 2L exit sign 3 2’x4’x 2L sm 1 Inc. 1L 2 l’x4’x 2L sm wp 1 Inc. 2L exit sign 2 l’x4’x 2L 2 l’x4’x 2L 8 2’x8’ 2L sm box 1 2’x8’ 2L sm box 1 2’x8’ 2L sm box Lamp Type Hours Qty F96T1260w 3120 F40T1234w 3120 F40T1234w 3120 F40T12 34w 800 2 F40T12 34w 3500 2 F40T12 34w 3500 2 F40T1234w 3500 2 F40T1234w 3500 2 F40T1234w 3500 2 F40T1234w 3500 1 F40T1234w 4000 2 F40T1234w 4000 2 Ioc.20w 8760 2 F40T1234w 4000 1 F40T1234w 4000 1 F40T12 34w 4000 2 F40T12 34w 4000 2 F40T1234w 4000 1 F40T12 34w 4000 2 Inc. 20w 8760 1 F40T12 3~w 4000 1 F40T1234w. 1200 1 F20T1220w 1200 1 F40T1234w 4000 1 F20T12 20w 4000 1 F40T12 34w 4000 6 F40T12 34w 3500 2 Inc. 20w 8760 2 F40T1234w 3500 2 F40T12 34w 3500 2 Inc. 20w 8760 2 F40T12 34w 800 1 Inc. 100w 800 2 F40T12 34w 3500 2 Inc. 20w 8760 2 F40T1234w 3120 2 F40T1234w. 3120 2 F96T1260w 3120 2 F96T12 60w 3120 2 F96T1260w 3120 Proposed Conditions Retrofit Description 8 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 38 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 131 (1) F32T8 lamp, (.25) 4L Ip elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 3 LED exit sign w/batt backup when needed 1 (2) F32T8 lamp, (1) 2L nl elect bllst 42 (1) F32T8 lamp, (1) 1L Ip elect bllst 54 (1) F32T8 lamp, (.5) 2L Ip elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 15 (2) F32T8 lamp, (.5) 4L nl elect bllst 80 (1) F32T8 lamp, (.5) 2L Ip elect bllst 2 LED exit sign w/bait backup when needed 80 (1) F32T8 lamp, (.5) 2L Ip elect bllst 33 (1) F32T8 lamp, (1) 1L Ip elect bllst 4 (1) F17T8 lamp, (1) 1L Ip elect bllst 24 (1) F32T8 lamp, (.5) 2L Ip elect bllst 4 (1) F17T8 lamp, (1) 1L Ip elect bllst 12 (1) F32T8 lamp, (.5) 2L Ip elect bllst 20 (6) F32T8 lamp, (2) 3L Ip elect bllst 4 LED exit sign w/bali backup when needed 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (.5) 4L nl elect bllst 0 LED exit sign w/bait backup when needed -3 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (1) CF 22w lamp and ballast 2 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 LED exit sign w/bait backup when needed 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 8 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 1 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 1 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan Energy Masters International Page 3 City of Palo Alto Cubberley Community Ref #Room # 119 J2 Office 2 120 J3 121 J3 Office 122 J4 123 J4 Office 124 J5 125 J6 126 .J7 Building K - 1st Floor 100 K7 12 101 K6 3 102 K6 .2 103 K7 Office 2 104 K6 Room 2 105 K5 3 106 K5 5 107 K5 10 108 K4 9 109 K4 Office 1 110 K4 Bathroom 1 111 K3 12 ¯ 112 K3Office 113 K Boy’s Restroom 2 Building L - 1st Floor. 63 L1 16 64 L1 4 65 L1 Restroom 1 66 L1 Office 6 67 L1 Storage 1 68 L1 Mezz 14 69 L1 Teacher’s Work 2 70 L1 Teacher’s Work 2 71 L1 Language Room 2 72 L1 A 4 73 L1 Kitchen 2 74 L2 Office 6 75 L1 main 2 76 L3 Dance 4 77 L3 Dance 25 78 L3 Dance 3 79 L3 Office 2 80 L3 Hall 2 - 4000 Middlefield Road Existing Conditions City Description. Lamp Lamp Type Hours City 1 2’x8’ 2L sm box 2 F96T12 60w 3120 18 l’x4’x2Lsmwp 2 F40T1234w 3120 1 Inc. 1L 1 Inc. 300w -3120 24 l’x4’x2Lsmwp 2 F40T1234w 3120 1 Inc. lL 1 Inc. 100w 3120 12 2’x8’ 2L sm box 2 F96T12 60w 3120 12 2’x8’ 2L sm box 2 F96T12 60w 3120 12 2’x8’ 2L sm box - 2 F96T12 60w 3120 1’x8’ 2L sm box 1’x8’ 2L sm box 2’x4’x 2L Inc. 1L Circuline 2’x4’ 4L sm wp Inc. 1L 2’x4’ 4L sm wp l’x4’x 2L 2’x4’ 4L sm wp 1 ’x4’ 4 L 2’x4’ 4L sm wp 2’x4’ 4L sm wp 2’x4’ 4L sm wp l’x4’x 2L 2 2 2 1 4 1 4 2 4 4 4 4 4 2 2’x8’ 3L sm hood 1’x6’ 3L hood l’x4’x 2L sm wp l’x4’x 2L sm wp l’x4’x 2L sm wp l’x4’x 2L sm wp l’x4’x 2L sm wp l’x4’x 2L sm wp l’x4’x 2L sm wp 1’x4’ 4L PM wp l’x4’x 2L sm wp l’x4’x 2L sm wp Inc. 2L exit sign l’x4’x 2L sm wp 1’x8’ 4L sm hood 1’x8’ 4L sm box l’x4’x 2L sm wp l’x4’x 2L sm wp 3 3 2 2 2 2 2 2 2 4 2 2 2 2 4 4 2 2 F96T12 60w 3120 F96T12 60w 3120 F40T12 34w 3120 Inc. 24w 3120 F40T12 34w 3120 Inc. 100w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 ¯ F40T12 34w 3120 F40T12 34w 3120 F96T1260w 3120 F72T1255w 3120 F40T1234w 3120 F40T12 34w 3120 F40T12 34w 800 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T1234w 3120 F40T12 34w 3120 F40T1234w 3120 Inc. 20w 8760 F40T1234w 3500 F96T1260w 3500 F96T1260w 3500 F40T1234w 3500 F40T1234w 3500 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Descdpt!on .1 (4) F32T8 lamp, (1) 4L Ip elect bllst0 (1) bracket kit, (1) ballast pan 18 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 24 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 22w lamp and.ballast 12 (4) F32T8 lamp, (1) 4L Ip.elect bllst, (1) bracket kit, (1) ballast pan 12 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 12 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 12 (4) F32T8 lamp, (1) 4L Ip electbllst, (1) bracket kit,-(1) ballast pan 3 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 DND (items left as is) 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 3 (1) CF 22w lamp and ballast 5 (4) F32T8 lamp, (1) 4L Ip elect bllst 10 (2) F32T8 lamp, (1) 2L nl elect bllst 9 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 12 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 16 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 4 New l’x8’x 4L wrap, w/(4) F32T8 lamps, (1) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect blrst 14.(2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (4) F32T8 lamp, (1) 4L Ip elect bllst ¯ 2 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 LED exit sign w/balt backup when needed 4 (2) F32T8 lamp, (1) 2L nl elect bllst 25 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 4 City of Palo Alto Cubberley Community - 4000 Middlefield Road RETROFIT SCOPE REPORT Ref #Room # Existing Conditions City Description 81 L3 A 4 l’x4’x 2L sm wp 82 L3 B 2 l’x4’x 2L sm wp 83 L4 24 1’x8’ 4L sm hood 84 L4 Storage 2 l’x4’x 2L sm wp 85 L4 Office 1 2’x4’x 2L 86 L4 Hall 4 l’x4’x 2L sm wp 87 L4 Hall 2 Inc. 2L exit sign 88 L4 Men’s Restroom 1 1’x8’ 4L sm box 89 L4 Women’s 1 1’x4’ 4L PM wp 90 L4 Storage 3 1’x8’ 2L stdp 91 L4 Mezz 2 1’x8’ 4L sm box 92 L4 Mezz Storage 2 l’x4’x 2L sm wp 93 ;L4MezzStorage 1 l’x8’2Lstdp 94 L4 Mezz Storage -4 l’x4’x 2L sm wp 95 L5 16 1’x8’ 2L sm hood 96 L6 Storage 3 Inc. 1L 97 L6 Storage 2 1 Inc. 2L dome 98 L6 12 l’x8’2Lsmhood 99 L6 Storage 3 2 Inc. 1L Building M - 1 st Floor 304 M Hallway 6 l’x4’x 2L 2 305 M Hallway 3 Inc. 2L exitsign 2 306 M4 15 1’x8’ 2L sm 2 307 M6 2 l’xS’2Lsm 2 308 M3 6 2’xS’2L 2 309 M3B 2 l’x4’x 2L 2 310 M3C 2 l’x4’x 2L 2 311 Women’s Restroom 1 l’x4’x 2L 2 312 M2 12 l’x8’2Lsm 2 313 Men’s R~i~troom 1 l’x4’x 2L 2 314 Custodial Closet 1 Inc. 1L 1 315 Closet#2 1 Inc. lL 1 316 M1Office 2.l’x4’x2L 2 317 M5 1 l’x4’x2L 2 318 M7 2 l’x4’x2L 2 319 Mll 1 l’x4’x2L 2 320 M8 2 Inc.2Ldome 2 321 . M9 1 Inc. 2L dome 2 Building MPR - ’lst Floor 220 Multipurpose Room 36 Inc. 1L 1 221 Multipurpose Room 4 Inc. 1L 1 222 Multipurpose Room 4 Inc. 2L exit sign 2 Lamp 2 2 4 2 2 2 2 4 4 2 4 ’ 2 2 2 2 1 2 2 1 Energy Masters International Lamp Type Hours City F40T12 34w 3500 F40T12 34w 3500 F96T12 60w 3500 F40T12 34w 800 F40T12 34w 3500 F40T12 34w 3500 Inc. 20w 8760 F96T12 60w 3500 F40T12 34w 3500 F96T12 60w 800 F96T12 60w 3500 F40T12 34w 3500 F96T12 60w 3500 F40T12 34w 3500 F96T12 60w 3500 Inc. 100w 3500 Inc. 60w 800 F96T12 60w 3500 Inc. 100w 1500. F40T1234w 3120 Inc. 20w 8760 F96T12 60w 3120 F96T12 60w 3120 F96T1260w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F96T1260w 3120 F40T1234w 3120 Inc. 60w 800 Inc. 100w 800 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 Inc. 60w 3120 Inc. 60w 3120 Inc.500w 2700 Inc. 100w 2700 Inc. 20w 8760 Page 5 4 2 24 2 1 4 2 1 1 3 2 2 1 4 16 3 1 12 2 Proposed Conditions Retrofit Description (2) F32T8 lamp, (.5) 4L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst LED exit sign w/bait ba¢l~up when needed (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (4) F32T8 lamp, (1) 4L Ip elect bllst (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit (8) F32T8 lamp, (2) 4L Ip elect bllsl, (1) bracket kit, (1) ballast pan (2) F32T8 lamp, (1) 2L nl elect bllst (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit (2) F32T8 lamp, (.5) 4L nl elect bllst (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (1) CF 22w lamp and ballast New sm drum with (2) CF 15 watt lamps and ballast (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (1) CF 22w lamp and ballast 6 (2) F32T8 lamp, (1) 2L nl elect bllst 3 LED exit sign w/batt backup when needed 15 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 2 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 6 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 15w lamps and ballast 1 (1) CF 22w lamp and ballast 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 New sm drum with (2) CF 15 watt lamps and ballast 1 New sm drum with (2) CF 15 watt lamps and ballast 36 New 2’x2’x 4L box, w/(4) TT55 lamps, (2) 2L Ip elect bllst 4 (1) CF 22w lamp and ballast 4 LED exit sign w/batt backup when needed City of Palo Alto Cubberley Community - 4000 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref #Room #City Description 223 Kitchen 4 Inc. 1L 224 ’ Kitchen 9 l’x4’x 2L PM wp 225 Janitor Closet 1 Inc. 1L. 226 Storage 1 Inc. 1L 227 Restroom 1 Inc. 3L sm dome 228 Storage #2 0 DND 229 Storage#3 1 Inc. 1L 230 Freezer 1 Inc. 1L 231 Dishwashing 6 l’x4’x 2L sm Vapor 232 Lounge 6 2’x2’ 2L 233 Men’s Restroom 1 Inc. 3L sm dome 234 Men’s Restmom 1 Inc. 2L sm dome 235 Women’s Restroom 1 Inc. 3L sm dome 236 Women’s Restroom -1 Inc. 2L sm dome 237 Back Stage Hall 1 Inc. 1L 238 Back Stage Hall 4 l’x4’4LPMwp Building P - 1st Floor 50 P1 9 2’x4’4Lsmbox 51 P1 1 2’x8’ 4L sm prsm 52 P4 15 2’x4’4Lsmbox 53 P4 Office 3 2’x4’ 4L sm box 54 P1 Office 1 2 l’x4’x 2L smwp 55 P1 Office 2 2 l’x4’x 2L sm wp 56 P1 Storage 1 Inc. lL 57 P2 4 2’x4’ 4L sm box 58 P2 8 2’x8’ 4L sm prsm 59 P3 4 2’x4’ 4L sm box 60 P3 ¯8 2’xS’4Lsmprsm 61 P Men’s Restmom 0 No Access 62 P Women’s Restroom 0 No Access Building S - 1st Floor 239 Rear Hall 1 l’x4’x 2L sm Vapor 240 Kitchen 1 l’x4’x 2L sm Vapor 241 Classroom #1 6 1’x8’ 3L 242 Classroom #2 6 1’x8’ 3L 243 Classroom#3 28 l’x4’xlLsmwp 244 Classroom#3 2r l’x4’x2LsmVapor 245 Kitchen 2 4 l’x4’x 1L sm wp 246 Kitchen 2 2 l’x4’x 2Lsm Vapor 247 Kitchen Restroom 2 l’x4’x 2L sm Vapor 248 Classroom #4 6 1’x8’ 2L sm 249 Classroom #5 6 1’x8’ 3L sm Lamp Lamp Type Hours Qty 1 Inc. 100w 2700 2 F40T12 34w 2700 1 Inc. 100w 800 1 .Inc. 100w 800 3 Inc. 60w 2700 0 n/a 800 1 Inc. 300w 800 1 Inc. 300w 800 2 F40T12 34w 2700 2 FB40T12 2700 3 Inc. 60w 2700 2 Inc. 60w 2700 3,Inc. 60w 2700 2 Inc. 60w 2700 1 Inc. 100w 1500 4 F40T12 34w 1500 4 F40T12 34w 3120 4 F96T12 60w 3120 4 F40T12 34w 3120 4 F40T12 34w 3120 2 F40T12 34w 3120 2 F40T12 34w 3120 1 Inc. 100w 800 4 F40T12 34w 3120 4 F96T12 60w 3120 4 F40T12 34w 3120 4 F96T12 60w 3120 0 n/a 800 0 n/a 800 2 F40T12 34w 3120 2 F40T12 34w 3120 3 F96T12 60w 3120 3 F96T12 60w 3120 1 F40T12 34w 3120 2 F40T12 34w 3120 1 F40T12 34w 3120 2 F40T12 34w’3120 2 F40T12 34w 3120 2 F96T12 60w 3120 3 F96T12 60w 3120 Proposed Conditions Retrofit Description (1) CF 22w lamp and ballast (2) F32T8 lamp, (1) 2L nl elect bllst (1) CF 22w lamp and ballast (1) CF 22w lamp and ballast New sm drum with (3) CF 15 watt lamps and ballast DND (items left as is) New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst DND (items left as is) (2) F32T8 lamp, (1) 2L nl elect bllst (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl New sm drum with (3) CF 15 watt lamps and ballast New sm drum with (2) CF 15 watt lamps and ballast New sm drum with (3) CF 15 watt lamps and ballast New sm drum with (2) CF 15 watt lamps and ballast (1) CF 22w lamp and ballast (4) F32T8 lamp, (1) 4L Ip elect bllst 9 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 1 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 15 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 22w lamp and ballast 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 8 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 8 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 0 DND (items left as is) 0 DND (items left as is) 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (6) F32T8 lamp, (2) 3L Ip elect bllst, (1) bracket kit, (1) ballast pan 6 (6) F32T8 lamp, (2) 3L Ip elect bllst, (1) bracket kit, (1) ballast pan 28 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 6 (6) F32T8 lamp, (2) 3L Ip elect bllst, (1) bracket kit, (1) ballast pan Energy Masters International Page 6 City of Palo Alto Cubberley Community - 4000 Middlefield Road Existing Conditions Ref # Room # Qty Description Lamp 250 Infant 1 3 1’x8’ 2L sm 2 251 Infant1 1 l’x4’x2Lsmwp 2 252 Classroom #6 3 1’x8’ 2L sm 2 253 Classroom #6 3 l’x4’x 2L sm wp 2 Building T - 1st Floor 1 Family Resources 8 l’x4’x 2L sm wp 2 2 Main Office 18 l’x4’x 2L sm wp 2 3 Del Thorpe 2 2’x4’ 4L sm wp 4 4 Kathy Espinosa 2 2’x4’ 4L sm wp 4 5 Murphy Office 2 2’x4’ 4L sm wp 4 6 Kitchen/Lunch Room 2 2’x4’4L sm wp 4 7 Storage Room .1 Inc. 1L 1 8 Cl Women’s 1 1’x4’ 4L sm wp 4. 9 Cl Men’s Restroom 1 1’x4’ 4L sm wp 4 10 Cl Maggie’s Office 2 2’x4’ 4L sm wp "4 11 Bree’s Office Cl 1 2’x4’ 4L sm wp 4 12 T2 Human 4 2’x4’ 4L sm wp 4 13 T2Human 1 Inc. 2L 2 14 T2Human 1 Inc. 2Lsmdome 2 15 T1 Lobby 5 2’x4’ 4L sm wp 4 16 Office 2 2’x4’ 4L sm wp 4 17 Toddler 1 6 2’x4’ 4L sm wp 4 18 Toddler 1 1 Inc. 2L sm dome 2 19 Office 2 2’x4’ 4L sm wp 4 20 Infant1 Comm 12 2’x4’4Lsmwp 4 .21 T30 1 2’x4’4Lsmwp 4 Building U - 1st Floor 28 U1 6 l’x4’x2Lsmwp 29 U2 4 2’x4’ 4L rec prsm 30 U2 6 l’x4’x2Lsmwp 31 U3 1 2’x8’4L 32 U4 16 2’x4’4Lrecprsm 33 U5 16 2’x4’4Lrecprsm 34 U6 1 Inc. lL 35 U7 25 2’x4’ 4L rec prsm Building V - 1st Floor 22 Open Area 16 2’x4’ 4L req prsm 4 23 Kitchen 4 2’x4’x 2L rec prsm 2 24 Open Area 13 2’x4’ 4L rec prsm 4 25 Isolation 1 2’x4’ 4L rec prsm 4 Lamp Type Hours City F96T12 60w 3120 F40T12 34w 3120 F96T1260w 3120 F40T123~w 3120 F40T12 34w 3120 F40T1234w 3120 F40T1234w 3120 F40T12 34w 3120 F40T1234w 3120 F40T12 34w 3120 Inc. 100w 800 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T12 34w 3120 F40T1234w 3120 Inc. 75w 3120 Inc. 60w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 Inc. 60w 3120 F40T1234w 3120 F40T12 34w 3120 F40T12 34w 3120 2 F40T12 34w 3120 4 F40T1234w 3120 2 F40T12 34w 3120. 4 F96T12 60w 3120 4 F40T12 34w 3120 4 F40T12 34w 3120 1 Inc..100w 3120 4 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T12 34w 3120 F40T1234w 3120 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 3 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 3 (2) F32T8 lamp, (1) 2L nl elect bllst 8 (2) F32T8 lamp, (.5) 4L nl elect bllst 18 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (4) F32T8. lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (1) CF 22w lamp and ballast 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 4 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (2) CF 22w lamps andballast 1 New sm drum with (2) CF 15 watt lamps and ballast 5 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect hllst 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 New sm drum with (2) CF 15 watt lamps and ballast 2 . (4) F32T8 lamp, (1) 4L Ip elect bllst 12 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip ele.ct bllst WS ws WS ws WS 6 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 6 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 16 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 16 (2) F32T8. lamp, (1) 2L nl elect bllst, (1) rfl 1 (1) CF 22w lamp and ballast 25 (2) F32T8 lamp, (1).2L nl elect bllst, (1) rfl 16 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 13 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl Energy Masters International Page 7 City of Palo Alto Cubberley Community - 4000 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Lamp Type 26 Storage 0 DND 0 n/a 27 Outside 2 CF 1L rec Sq 1 CF 15w Gym A - 1st Floor 254 Gym A 20 HID 0 HID 255 Gym A 3 Inc. 2L exit sign 2 Inc. 20w .256 Gym A Hall 3 Inc. 2L dome 2 Inc. 60w 257 DomeS1 12 HID 0 HID 258 Dome $2 12 HID 0 HID 259 Storage #1 1 Inc. 1L 1 Inc. 100w 260 Storage #2 1 l’x4’x 2L sm wp 2 F40T12 34w 261 Storage #2 1 Inc. 1L 1 Inc. 100w 262 Women’s Locker 20 Inc. 1L 1 Inc. 300w 263 AV Lab 3 Inc. 1L 1 Inc. 300w 264 AV Lab 1 2’x2’ 2L 2 FB40T12 265 Locker Storage 1 Inc. 1L 1 Inc. 100w 266 Storage #3 1 Inc. 1L 1 Inc. 300w 267 Storage #4 1 l’x4’x 2L sm wp 2 F40T12 34w Gym B - 1st Floor 268 Weight Room 12 HID 0 HID 269 Maintanence Shop 6 Inc. 1L 1 Inc. 300w 270 Storage 3 l’x4’x 2L sm wp 2 F40T12 34w 271 Boy’s Locker 2 Inc. 2L dome 2 Inc. 60w 272 Boy’s Locker 13 Inc. lL 1 Inc. 100w 273 Boy’s Locker 5 Inc. 1L 1 Inc. 300w 274 Boy’s Gym 24 HID 0 . HID 275 Boy’s Gym 4 Inc. 2L exit sign 2 Inc. 20w Pavillion - 1st Floor 276 Storage 4 Inc. 1L i Inc. 300w 277 Men’s Locker 3 Inc. 1L 1 Inc. 100w 278 Locker Office 2 2’x4’ 4L 4 F40T12 34w 279 Men’s Locker Room 9 Inc. 1L 1 Inc. 300w 280 Men’s Locker Room 1 Inc. 1L 1 Inc. 100w 281 Office Storage 1 2’x4’ 4L 4 F40T12 34w 282 Equipment Storage 3 Inc. 1L 1 Inc. 300w 283 Ball Storage 1 2’x4’ 4L 4 F40T12 34w 284 Locker Storage 2 Inc. 1L 1 Inc. 300w 285 Locker Storage 1 Inc. 1L 1 Inc. 100w 286 Snack Bar 4 2’x4’ 4L 4 F40T12 34w ’ 287 Pavillion Lobby 8 2’x2’ 2L 2 FB40T12 288 Pavillion Lobby 2 Inc. 2L exit sign 2 Inc. 20w Hours Qty 800 0 DND (items left as is) 4380 2 DND (items left as is) Proposed Conditions Retrofit Description 2700 20 DND (items left as is) 8760 3 LED exit sign w/bait baekup when ~eeded 2700 3 New sm drum with (2) CF 15 watt lamps and ballast 2700 12 DND (items left as is) 2700 12 DND (items left as is) 800 1 (1) CF 22w lamp and ballast 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (1) CF 22w lamp and ballast 3120 20 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 3120 3 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 3120 1 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 800 1 (1) CF 22w lamp and ballast 800 t New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 12 DND (items left as is) 3120 6 New 1,x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 800 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 2 New sm ,drum with (2) CF 15 watt lamps and ballast 3120 13 (1) CF 22w lamp and ballast 3120 5 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 2700 24 DND (items left as is) 8760 4 LED exit sign w/batt backup when needed 800 4 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 3120 3 (1) CF 22w lamp and ballast 3120 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) ffl 3120 9 New l’x4’x 2L wrap, w/(2) F32T8 lamps,-(1) 2L Ip elect bllst 3120 1 (1) CF 22w lamp and ballast 3120 1 (2) F32T8 lamp, (1) 2L hi elect bllst, (1) rfl 80.0.3 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) dl 800 2 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 800 1 (1) CF 22w lamp and ballast 800 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 8 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 8760 2 LED exit sign w/batt backup when needed Energy Masters International Page 8 Cily of Palo Alto Cubberley Community - 4000 Middlefield Road Existing Conditions Ref# Room # Qty Description Lamp Lamp Type Hours 289 - Lobby Restroom 2 2’x2’ 2L 2,FB40T12 1500 290 Lobby Restroom 2 2’x2’ 2L 2 FB40T12 1500 291 Gym 8 HID 1 HID 2700 Theatre - 1st Floor 292 Theatre Lobby 4 Inc. 1L 1 Inc. 100w 293 Theatre Lobby 4 Inc. 2L exit sign 2 Inc. 20w 294 Office 1 Inc. 2L dome 2 Inc. 60w 295 Stairwell -1 Inc. 1L 1 Inc. 100w 296 Stairwell 1 Inc. 2L dome 2 Inc. 60w 300 Storage #4 1 Inc. 1L 1 Inc. 100w 301 Storage #5 1 Inc. 1L 1 Inc. 100w 302 Stage .6 1’x4’ 4L sm wp 4 F40T12 34w 303 Shop 2 Inc. 1L PM Hoods 1 Inc. 200w 2rid Floor 297 Control Room 12 l’x4’x 2L 2 F40T12 34w 800 298 Storage#2 1 Inc. 1L 1 Inc. 100w 800 299 Cat Walk 0 DND 1 n/a 800 2088 2 2 8 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl DND (items left as is) 3120 4 (1) CF 22w lamp and ballast 8760 4 LED exit sign w/batt backup when needed 3120 1 New sm drum with (2) CF 15 watt lamps and ballast 8760 1 (1) CF 22w lamp and ballast 8760 1 New sm drum with (2) CF !5 watt lamps and ballast 800 1 (t) CF 22w lamp and ballast 800 1 (1) CF 22wlamp and ballast 800 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 800 2 New l’x4’x 2L:.wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 12 1 0 2088 (2) F32T8 lamp, (1) 2L nl elect bllst (1) CF 22w lamp and ballast DND (items le~ as is) Energy Masters International Page 9 City of Palo Alto Cultural Center- 1313 Newell Rd RETROFIT SCOPE REPORT Existing Conditions Ref # Room # City Description Main Building - 1st Floor 1 Exhibit Hall 2 Front Exhibit 3 Volunteer Project 4 Hall Report 5 Hall 6 Director 7 Director 8 Men’s Restroom 9 Men’s Restroom 10 Women’s Restroom 11 Women’s Restroom 12 Project Room 13 Storage Room 14 Art & Tech Studio 15 Storage 16 Break Room 17 Break Room 18 Studio A 19 Studio A 20 Office Studio A 21 Women’s Restroom 22 Women’s Restroom 23 Men’s Restroom 24 Men’s Restroom 25 Kelm Room 26 Stai~ell 29 Mechanical Room 30 Mechanical Room 31 Storage 32 ¯ Office 33 Office 34 Office Director Green 35 Truck 36 Pan AM Exhibit morn 37 Hallway Back 38 Exhibit Hall 39 Exhibit Hall 40 Exhibit Hall 41 Exhibit Hall 42 M RR back hallway 43 M RR back hallway 44 W RR back hallway 0 Track Lighting 3 4’x4’ 4L t2 l’x4’x 2L sm wp 1 2’x4’ 4L 6 2’x2’ 2L 2 l’x4’x 2L sm wp 2 4’x4’ 4L sm box 1 l’x4’x 2L sm wp 1 Inc. 2L sm. Square 1 l’x4’x 2L sm wp 1 Inc. 2L sm Square 4 4’x4’ 4L sm box 2 4’x4’ 4L sm box 24 l’x4’x 2L sm wp 2 l’x4’x 2L sm wp 12 Inc. 2L sm Square 3 l’x4’x 1L strip 86 l’x4’x 2L sm wp 4 Inc. 2L exit sign 2 2’x4’ 4L 2 Inc. 2L sm Square 1 Inc. 1L 2 Inc. 2L sm Square 1 Inc. 1L 4 l’x4’x 2L sm wp 2 Inc. 2LsmSquare 1 l’x4’x 1L strip 4 Inc. 1L ¯ 3 Inc. 1L 5 4’x4’ 4L sm box 3 Inc. 1L box 6 3’x3’ 4L sm box 0 DND 6 4’x4’ 8L 1 " Inc. 2L exit sign 3 3’x3’ 6L 3 4’x4’ 6L 2 Inc. 2L exit sign 36 l’x4’x 2L custom 1 2’x2’ 2L 1 Inc. 1L rec square 1 2’x2’ 2L Lamp Lamp Type Hours City 0 n/a 2000 4 F40T12 34w 2000 2 F40T12 34w 2000 4 F40T12 34w 2000 2 FB40T12 2000 2 F40T1234w 2000 4 F40T1234w 2000 2 F40T1234w 2000 2 Inc. 100w 2000 2 F40T12 34w 2000 2 Inc. 100w 2000 4 F40T12 34w 800 4 F40T1234w 800 2 F40T12 34w 2000 2 F40T12 34w 800 2 Inc. 100w 2000 1 F40T1234w 2000 2 F40T1234w 2000 2 Inc. 20w 8760 4 F40T1234w 2000 2 Inc. 100w 2000 1 Inc. 100w 2000 2 Inc. 100w 2000 1 Inc. 100w 2000 2 F40T12 34w 2000 2 Inc. 100w 8760 1 F40T1234w 1100 1 Inc. 100w 800 1 Inc. 100w 800 ¯ 4 F40T12 34w 2000 1 Inc. 50w 2000 4 F30T12 2000 0 n/a 2000 8 F40T12 34w 2000 2 Inc.20w 8760 6 F30T12 2000 6 F40T12 34w 2000 2 Inc. 20w 8760 2 F40T1234w 2000 2 FB40T12 2000 1 Inc. 60w 2000 2 FB40T12 2000 Proposed Conditions Retrofit Description 0 DND (items left as is) 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 6 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rft 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (4) F32T8 lamp, (t) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New sm drum with (3) CF 15 watt lamps and ballast 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New sm drum with (3) CF 15 watt lamps and ballast 4 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 24 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst -~ 12 New sm drum with (3) CF 15 watt lamps and ballast 3 (1) F32T8 lamp, (1) 1L Ip elect bllst 86 (2) F32T8 lamp, (.5) 4L nl elect bllst 4 LED exit sign w/bait backup when needed 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 New sm drum with (3) CF 15 watt lamps and ballast. 1 (1) CF 22w lamp and ballast 2 New sm drum with (3) CF 15 watt lamps and ballast .1 (1) CF 22w lamp and ballast 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 New sm drum with (3) CF 15 watt lamps and ballast 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 4 (1) CF 22w lamp and ballast 3 (1) CF 22w lamp and ballast 5 (4) F32T8 lamp (1) 4L Ip elect bllst " 3 (1) CF 22wlamp and ballast 6 (4) F25T lamps, (1) 4L Ip elect bllst 0 DND (items left as is) 6 (8) F32T8 lamp, (2) 4L Ip elect bllst 1 LED exit sign w/batt backup when needed 3 (6) F25T lamps, (2) 3L Ip elect bllst 3 (6) F32T8 lamp, (2) 3L Ip elect bllst 2 LED exit sign w/batt backup when needed 36 (2) F32T8 lamp, (1) 2L nl elect bllst 1.(3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfi 1 (1) CF 22w lamp and ballast 1 (3) F17T8 lamp, (1)2L Ip elect bllst, (1) rft Energy Masters International Page 1 City of Palo Alto Cultural Center- 1313 Newell Rd RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description 45 W RR back hallway 1 Inc. 1L rec square 46 Exterior 15 Inc 2L pars 47 Exterior 1 Inc. 1L par 48 Exterior 1 Inc. 1L rec square 49 hallway 1 Inc. 1L rec Square 50 Auditorium 4 Inc. 8L decorative Basement 27 Basement 20 l’x4’x2Lsmwp 28 Basement 25 Inc. 1L box 325 Lamp 1 2 1 1 1 1 2 1 Lamp Type Inc. 60w Inc. 150w Inc. 150w Inc. 60w Inc. 100w Inc. 100w F40T12 34w Inc. 50w Proposed Conditions Hours Qty Retrofit Description 1100 1100 2000.1 (1) CF 22w lamp and ballast 4380 15 New HPS wall pack (1) 70w HPS lamp and ballast 4380 1 New HPS wall pack (1) 70w HPS lamp and ballast 4380 1 (1) CF 22w lamp and ballast 2000 1 (1) CF 22w lamp and ballast 1500 4 DND (items left as is) 20 25 325 (2) F32T8 lamp, (1) 2L nl elect bllst DND (items left as is) Energy Masters Internalional Page2 City of Palo Alto Downtown Library - 270 Forest Avenue RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 Main Area 2 Main Area 3 Main Area 4 Main Area 5 Reference Help 6 . Staff Office 7 Kitchen 8 Kitchen 9 Staff Bathroom 10 Staff Bathroom 11 Juvenille Books 12 Staff Office #2 13 Library Admin 14 Hall Restroom 15 Men’s Restroom 16 Men’s Restroom 17 Women’s Restroom 18 Women’s Restroom 19 Closet 23 4’x4’ 8L sm Opaque 14 2’x4’ 4L sm Opaque 4 2’x2’ 2L sm Opaque 2 LED exit sign 8 4’x4’ 8L sm Opaque 8 4’x4’ 8L sm Opaque 2 4’x4’ 8L sm Opaque 1 l’x4’x 1L sm stdp 2 Inc. 1LrecCan 1 Inc. 1L Vanity 1 4’x4’ 8L sm Opaque ’-4 4’x4’ 8L sm Opaque 8 4’x4’ 8L sm Opaque 6 Inc. 1L rec Can 2 l’x4’x 2L 1 4L Vanity 2 l’x4’x 2L 1 4L Vanity 1 Inc. 1LrecCan 91 Lamp Lamp Type Hours Qty 8 F40T12 34w 4000 23 4 F40T12 34w 4000 14 2 FB40T12 4000 4 1 LED 8760 2 8 F40T12 34w 4000 8 8 F40T12 34w 3120 8 8 F40T12 34w 3120 2 1 F40T12 34w 3120 1 1 Inc. 100w 2000 2 1 Inc. 100w 2000 1 8 F40T12 34w 4000 1 8 F40T12 34w 3120 4 8 F40T12 34w 4000 8 1 Inc. 100w 2500 6 2 F40T12 34w 2500 2 4 Inc. 60w 2500 1 2 F40T12 34w 2500 2 4 Inc. 60w 2500 1- 1 Inc. 100w 800 1 9t Proposed Conditions Retrofit Description (8) F32T8 lamp, (2) 4L Ip elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl DND (items left as is) (8) F32T8 lamp, (2) 4L I~elect bllst (8) F32T8 lamp, (2) 4L Ip elect bllst (8) F32T8 lamp, (2) 4L Ip elect bllst (1) F32T8 lamp, (1) 1L Ip elect bllst (1) CF 22w lamp and ballast (1) CF 22w lamp and ballast (8) F32T8 lamp, (2) 4L Ip elect bllst (8) F32T8 lamp, (2) 4L Ip elect bllst (8) F32T8 lamp, (2) 4L Ip elect bllst (1) CF 22w lamp and ballast (2) F32T8 lamp, (1) 2L nl elect bllst New l’x2’x 2L vanity, w/(2) F17T8 lamps, (1) 2L Ip elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst New l’x2’x 2L vanity, w/(2) F17T8 lamps, (1) 2L Ip elect bllst (1) CF 22w lamp and ballast Energy Masters International Page1 City of Palo Alto Elcamino Park RR - 100 El Camino Ral Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 M RR l’x4’x 2L sm wp 2 W RR l’x4’x 2L sm wp Lamp 2 2 Lamp Type F40T12 34w F40T12 34w Hours 8760 8760 0 0 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Fire Station # 3 - 799 Embaracdero Road RETROFIT SCOPE REPORT Existing Conditions ¯ Ref # Room # Qty Description Main Building - 1st Floor 1 front office 1 l’x4’x 2L sm wp 2 bays 6 l’x8’x 4L rec fxt 3 Ty room 3 l’x6’x 3L rec fxt 4 shop 3 l’x8’x 4L hood 5 back hallway 3 l’x4’x 2L sm wp 6 Break Room 4 Inc. 1L rec can 7 MRR 2 Inc. 2Lvanity 8 WRR 2 Inc. 2L vanity 9 dorm #1 1 l’x4’x 2L sm wp 10 dorm #2 2 l’x4’x 2L sm wp 11 dorm #3 .1 l’x4’x 2L sm wp 12 weight room 8 l’x4’x 2L hood 36 Lamp 2 4 3 4 2 1 2 2 2 2 2 2 Lamp Type F40T12 34w F40T12 34w F72T12 55w F40T12 34w F40T12 34w Inc. 75w Inc. 60w Inc. 60w F40T12 34w F40T12 34w ¯ F40T12 34w F40T12 34w Proposed Conditions Hours City Retrofit Description 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 4000 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 1500 3 New l’x8’x 4L wrap, w/(4) F32T8 lamps, (1) 4L Ip elect bllst 1500 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 1500 3~ (2) F32T8 lamp, (1) 2L nl elect bllst 1500 4 (1) CF 22w lamp and ballast 1500 2 New l’x2’x 2L vanity, w/(2) F17T8 lamps, (1) 2L Ip elect bllst 1500 2 New l’x2’x 2L vanity, wl (2) F17T8 lamps, (1) 2L Ip elect bllst 800 1 (2) F32T8 lamp,.(1) 2L nl elect bllst 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 8 (2) F32T8 lamp, (1) 2L nl elect bllst 36 Energy Masters International Page 1 City of Palo Alto Fire Station #1 - 301 Alma St.RETROFIT SCOPE REPORT Ref #.Room # Existing conditions City Descdption Main Building - 1st Floor 1 lobby 3 2’x4’ 4L sm box 2 lobby 2 l’x4’x 2L sm wp 3 bays 24 l’x4’x 4L sm wp 4 Equipment Storage 2 l’x4’x 4L sm wp 5 back hallway 3 l’x4’x 2L sm wp 6 storage 1 Inc. 1L bare bulb 7.WRR 1 l’x2’xlLwm 8 captaing office 1 l’x4’x 4L sm wp 9 MRR 2 l’x2’xlLwm 10 office 1 l’x4’x 2L sm wp 11 office _1_l’x4’x 4L sm wp 12 captains dorm 1 l’x4’x 2L sm wp 13 kitchen 1 l’x4’x 2L sm wp 14 kitchen 2 l’x4’x 4L sm wp 15 kitchen 2 Inc. 1L oven jar 16 break room 8 l’x4’x 4L sm wp 17 break room 2 CF 1L sconce 2nd.Floor 18 Stairwell 1 4’x4’x 8L fxt 19 TV room 1 l’x4!x 2L sm wp 20 dorml 2 l’x4’x4Lsmwp 21 dorm 2 2 l’x4’x 4L sm wp 22 ’ RR 6 l’x4’x 2L sm wp 23 hallway 3 l’x4’x 2L sm ~p 72 Lamp 4 2 4 4 2 1 1 4 1 2 4 2 2 4 1 4 1 Lamp Type Hours Qty F40T12 34w 1500 F40T12 34w 1500 F40T12 34w 4000 F40T12 34w 800 F40T12 34w 1500 Inc. 60w 800 F17T8 1500 F32T8 1500 F17T8 1500 F40T12 34w 1500 F40T12 34w 1500 F40T12 34w 800 F32T8 1500 F32T8 1500 Inc. 100w 1500 F32T8 1500 CF 15w 1500 8 F40T1234w 8760 2 F32T8 1500 4 F32T8 8O0 4 F32T8 .. 800 2 F40T1234w 1500 2 F32T8 1500 Proposed Conditions Retrofit Description 3 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 24 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip~elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 22w lamp and ballast 1 DND (items left as is) 1 DND (items left asls) 2 DND (items left as is) 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 DND (items left as is) 2 DND (items left as Is) 2 DND (items left as is) 8 DND (items left as is) 2 DND (items left as is) 1 (8) F32T8 lamp, (2) 4L Ip elect bllst 1 DND (items left as is) 2 DND (items left as is) 2 DND (items left as is) 6 (2) F32T8 lamp, (1) 2L nl elect bllst 3 DND (items left as is) 72 Energy Masters International Page 1 City of Palo Alto Fire Station #2 - 2675 Hanover Street RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 1 TruckBay 16 l’x4’x2Lsmwp 2 2 Hall next to Furnace 4 l’x4’x 2L sm wp 2 3 Hall next to Furnace 1 Inc. 2L exit sign 2 4 FumaceRoom 1 Inc. lL 1 5 Locker Room 7 l’x4’x 2L sm Wp 2 6 Women’s Locker 5 l’x4’x 2L sm wp 2 7 Paramedic Door 1 l’x4’x 2L sm wp 2 8 Paramedic Door #2 1 l’x4’x 2L sm wp 2 9 . Fire Dept Store 2 l’x4’x 2L stdp 2 10 Weight Room 2 1’x4’ 4Lwp 4 11 ¯ Air Room _1 1’x4’ 4L wp 4 12 Men’s Locker Hall 3 l’x4’x 2L sm wp 2 13 Men’s Locker Hall 2 Inc. 2L exit sign 2 14 Engine Dorm 1 l’x4’x 2L sm wp 2 15 Captain Dorm 1 l’x4’x 2L sm wp 2 16 Dorm #2 1 l’x4’x 2L sm wp 2 17 Rescue Dorm 1 l’x4’x 2L sm wp 2 18 Electrical Room 1 Inc. 1L 1 19 Front Lobby 3 1’x4’ 4Lwp 4 20 Telephone Room 1 Inc. 1L - 1 21 Computer Room 1 4’x4’ 6L box 6 22 Rescue Dorm 1 1’x4’ 4L wp 4 23 TV Room 6 1’x4’ 4L wp 4 24 Kitchen 2 Jelly Jar 1 25 Kitchen 2 l’x4’x 1L wp 1 26 Kitchen 1 Inc. 1L dome 1 27 Rescue Dorm 2 Inc. 1L 1 28 Custodial 1 Inc. 1L 1 29 Exterior 3 Inc. 1L 1 30 Exterior 2 Inc. 1L dome 1 31 Exterior 2 Inc. 2L Can 2 32 Exterior 2 Inc. 2L Par 2 8O Lamp Type Hours Qty F40T12 34w 4000 F40T12 34w 1500 Inc. 20w 8760 Inc. 100w 1500 F40T12 34w 1500 F40T12 34w 1500 F40T12 34w 1500 F40T12.34w 1500 F40T12 34w 1500 F40T12 34w 1500 F40T12 34w 1500 F40T12 34w 1500 Inc. 20w 8760 F40T12 34w 1500 F40T12 34w 1500 F40T12 34w 800 F40T12 34w 800 Inc. 100w 800 F40T12 34w 2000 Inc. 100w 1500 F40T12 34w 1500 F40T12 34w 800 F40T12 34w 1500 Inc. 60w 1500 F40T12 34w 1500 Inc. 60w 1500 Inc. 100w 800 Inc.. 100w 800 Inc. 100w 4380 Inc. 60w 4380 Inc. 60w 4380 Inc. 150w 4380 Proposed Conditions Retrofit Description 16 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/batt backup when needed 1 (1) CF 22w lamp and ballast 7 (2) F32T8 lamp, (1) 2L nl elect bllst 5 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 LED exit sign w/bait backup when needed 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 . (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 22w lamp and ballast 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (1) CF 22w lamp and ballast 1 (6) F32T8 lamp, (2) 3L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 DND (items left as is) 2 (1) F32T8 lamp, (1) 1L Ip elect bllst 1 New sm drum with (2) CF 15 watt lamps and ballast 2 (1) CF 22w lamp and ballast 1 (1) CF 22w lamp and ballast 3 (1) CF 22w lamp and ballast 2 New sm drum with (2) CF 15 watt lamps and ballast 2 (2) CF 15w lamps and ballast 2 New HPS wall pack (1) 70w HPS lamp and ballast 80 Energy Masters International Page 1 City of Palo Alto Fire Station #4.3600 Middlefield Rd. Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 weight room 2 ,l’x4’x 4L fxt 2 bays 4 . 1’x8’ x2L hood 3 map display case 2 l’x4x’ 1L strip 4 office 1 l’x4’x 4L fxt 5 tool desk 1 l’x4’x 4L fxt 6 WRR 2 l’x4x’2Lsmwp 7 WRR 1 l’x2’xlLwm 8 W dorm 2 l’x4x’ 2L sm wp 9 MDorm 2 l’x4x’2Lsmwp 10 M locker room 4 l°x4x’ 2L sm wp 11 hallway ._1 l’x4x’ 2L sm wp 12 TV room 1 l’x4’x 4L fxt 13 TV room 4 Inc. track lighting 14 washer room’1 Inc. 1L bare bulb 15 water heater closet 1 Inc. 1L bare bulb 29 Lamp 4 2 1 4 4 2 1 2 2 2 2 4 1 1 Lamp Type F40T12 34w Fg6T12 HO F40T12 34w F40T12 34w F40T12 34w F40T12 34w F20T12 20w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc. 75w R40 Inc. 60w Inc. 60w Hours (~y RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 1500 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 4000 4 New l’x8’x 8L wrap, w/(8) F32T8 lamps, (2) 4L Ip elect bllst 8760 2 (1) F32T8 lamp, (1) 1L Ip elect bllst 2000 1 (4) F32T8 lamp, (1) 4L Ipelect hi!st 1500 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 1500 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (1) F17T8 lamp, (1) 1L Ip elect bllst 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 4 (2) F32T8 lamp, (1) 2L nl e!ect bllst 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (4) F32T8 lamp, (1).4L Ip elect bllst 1500 4 DND (items left as is) 800 1 (1) CF 22w lamp and ballast 800 1 (1) CF 22w lamp and ballast Energy Masters International Page1 City of Palo Alto Fire Station #5 - 600 Arastradero Road ~RETROFIT SCOPE REPORT Existing Conditions Ref #Room #City, Description Firestation #1 - ~ 1st Floor 1 TruckBay 16 l’x4’x2Lsmstrip 2 Locker Room Hall 1 Inc. 1L 3 Locker Room Hall 1 l’x4’x 2L rec prsm. 4 Women’s Restroom 2 2L Vanity 5 Men’s Restroom 3 2L Vanity 6 Locker Room #1 1 l’x4’x 2L rec prsm 7 Locker Room #2 1 l’x4’x 2L rec prsm 8 Dorm #1 1 l’x4’x 2L rec prsm 9 Dorm #2 1 l’x4’x 2L rec prsm 10 Control Room/Entry 1 l’x4’x 2L rec prsm 11 Library Study .._1_l’x4’x 2L rec prsm 12 TV Room "6 l’x4’x 2L rec prsm 13 - Kitchen 2 l’x4’x 2L rec prsm 14 Captain’s D0rm 1 Inc. 1L 15 Captain’s Dorm 1 2L Vanity 16 Captain’s Dorm 1 Inc. Globe 40 Lamp 2 1 2 2 2 2 2 2 2 2 2 2 2 1 2 1 Lamp Type F40T12 34w Inc. 100w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T’I2 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc. 100w F40T12 34w Inc. 60w Proposed Conditions Hours City Retrofit Description 4000 16 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (1) CF 22w lamp and ballast 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 3 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 6 (2) F32T8 lamp, (1) 2L nl elect bllst !100 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (1) CF 22wlamp and ballast 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (1) CF 15w lamps and ballast 40 Energy Masters International Page 1 City of Palo Alto Foothill Park Fire Station #8 - 3300 Page Mill Road Ref #Room # Main Building - tst Floor 18 Fire Station Existing Conditions City Description 0 No Access 0 Lamp Lamp Type n/a Hours 0 DND (items left as is) RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description Energy Masters International Page Cityof PaloAIto Foothill Park Interpretive Center - 3300 Page Mill Road RETROFIT SCOPE REPORT Existing Conditions Ref# Room# City Description Lamp LampType Hours City Main Building - 1st Floor 6 Women’s & Men’s 3 2’x2’ 2L sm box 2 FB40T12 1500 7 . Office#1 4 2’x4’4Lsmbox 4 F40T1234w 2000 8 Office#2 4 2’x4’ 4L sm box 4 F40T12 34w 2000 9 Office#3 8 2’x4’4Lsmbox 4 F40T1234w 2000 10 Storage 0 No Access 0 n/a 800 11 Conference Room 0 All TS’s 2 F32T8 800 12 Lobby 0 Inc. 1Lcustom 1 Inc..50w 2000 13 Storage 0 No Access 0 n/a 800 19 Proposed Conditions Retrofit Description 3 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 8 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 0 DND (items left as is) 0 DND (items left as is) 0 DND(items left as is) 0 DND (items left as is) 19 Energy Masters International Page 1 City of Palo Alto Foothill Park Lake RR- 3300 Page Mill Road Existing Conditions Ref # Room # Qty Description Main Building 1st Floor 4 Women’s Restroom - 5 Men’s Restroom 2 2’x2’ 2L sm box 2 2’x2’ 2L sm box 4 Lamp 2 2 .Lamp Type FB40T12 FB40T12 Hours 8760 8760 2 2 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) di (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl Energy Masters International Page 1 City of Palo Alto Foothill Park Oak Grove - 3300 Page Mill Road Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 1 Women’s Restroom 0 DND (no lights) Lamp Type n/a Hours DN[~ (items left as is) RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description Energy Masters International "Page 1 City of Palo Alto Foothill Park Orchard Glen RR - 3300 Page Mill Road Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 2 Women’s Restroom 3 Men’s Restroom 2 2’x2’ 2L sm box 1 2’x2’ 2L sm box 3 2 2 Lamp Type Hours Qbj . FB40T12 8760 2 FB40T12 8760 1 3 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl (3) F17T8 lamp, (1) 2L Ip elect bllst, (!) rfl Energy Masters International "Page 1 City of Palo Allo Foothill Park ShoplMaintenance - 3300 Page Mill Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Lamp Type Main Building - 1st Floor 14 Maintanence Facility 4 Inc. 1L par 1 . 15 Maintanence Facility 16 l’x4’x 2L chn pm 2 16 Shed #2 11 Inc. lLpar 1 17 Shed #2 1 1’x8’ 2L chn pm 2 32 Inc. 150w F40T12 34w Inc. 150w F96T12 60w Proposed Conditions Hours Qty Retrofit Description 4380 4 New HPS wall pack (1) 70w HPS lamp and ballast 1500 16 (2) F32T8 lamp, (.5) 4L nl elect bllst 4380 11 New HPS wall pack (1) 70w HPS lamp and ballast 1500 1 (4) F32T8 lamp, (1) 4L Ip-elect bllst, (1) bracket kit 32 Energy Masters International Page 1 City of Palo Alto Golf Course Maintenace Shop - 1875 Embarcadero Road Existing Conditions Ref # Room # .. Qty Description Lamp Main Building - 1st Floor 9 Cart Shop 10 Cart Shop Lamp Type Hours Qty 1 l’x4’x 2L 2 F40T12 34w 4380 1 12 l’x4’xlLsmwp 1 F40T1234w 4380 12 13 13 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst (1) F32T8 lamp, (.5) 2L Ip elect bllst Energy Masters International Page 1 City of Palo Alto Golf Course Office - 1875 Embarcadero Road RETROFIT SCOPE REPORT Existing Conditions ¯ Ref # Room # City Description Main Building - 1st Floor 3 Men’s Restroom. 4 Women’s Restmom 5 Restaurant 6 Kitchen 7 Kitchen 0 DND 0 DND 13 DND 3 l’x4’x 2L 4 1’x8’ 2L Vapor Tight 20 Lamp 1 1 1 2 2 Lamp Type CF 15w CF 15w Inc. 75w F40T12 34w F96T12 60w Proposed Conditions Hours City Retrofit Description 3600 0 DND (items left as is) 3600 0 DND (items left as is) 3600 13 DND (items left as is) 3600 3 (2) F32T8 lamp, (1) 2L nl-elect bllst 3600 " 4 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan 20 Energy Masters International Page 1 City of Palo Alto Golf Course Pro Shop - 1875 Embarcadero Road Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 1 Golf Shop Orce 2 Golf Shop Orifice 5 l’x4’x 2L 4 Inc. lLrec 9 2 1 Lamp Type F40T12 34w Inc. 75w Hours 3600 3600 5 4 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst (1) CF 22w lamp and ballast Energy Masters International Page 1 City of Palo Alto Golf Course RR- 1875 Embarcadero Road Ref #Room # ¯ Main Building - 1st Floor 8 Restroom Existing Conditions City Description 2 l’x4’x 2L 2 Lamp Lamp Type Hours Qty. 2 F40T12 34w 8760 2 2 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Greer Park RR - 1098 Amarillo Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 MRR 2 l’x4’x 2L sm wp 2 WRR 2 l’x4’x2Lsmwp 3 custodian room 1 Inc. 1L barn bulb 4 exterior 2 Inc. 1L vandal 7 Lamp 2 2 1 1 Lamp Type F40T12 34w F40T12 34w Inc. 75w Inc. 75w Proposed Conditions Hours City Retrofit Description 8760 2 (2) F32T8 lamp, (1) 21_ nl elect bllst 8760 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 1 (1) CF 22w lamp and ballast 4380 2 (1) CF 22w lamp and ballast 7 Energy Masters International Page 1 City of Palo Alto Harbor Master House - Embarcadero Road Baylands Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 1 all areas 0 dnd (site 0 0 Lamp Type n/a Hours 0 DND (items left as is) RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description Energy Masters International Page 1 City of Palo Alto Jr. Museum - 1451 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 Entry 2 Reception Area 3 Reception Area 4 Museum Area 5 Museum Area 6 Museum Area. 7 Office#1 8 Classroom #1 9 Classroom #1 10 Classroom #2 11 Classroom #2 12 Closet 13 Exhibit Hall 14 Exhibit Hall 15 Office #2 16 " Classroom #3 17 Classroom #3 18 Men’s Restroom t9 Women’s Restroom 20 Science Lab 21 Office 25 Zoo 2nd Floor 22 Office #1 23 Office #2 24 Office #3 6 2’x2’ 2L rec prsm 1 2’x2’ 2L rec prsm 4 l’x2’x 2L rec prsm 14 2’x2’ 2L rec prsm 6 l’x3’x 1L sm strip 6 l’x4’x 1L sm strip 6 l’x4’x 2L sm wp 16 1’x4’ 4L sm wp 1 Inc. 2L exit sign 6 l’x4’x 2L sm wp ~1_91’x4’ 4L sm wp 2 1’x4’ 4L sm wp 1 l’x4’x 2L sm wp 9 1’x4’ 4L sm wp 4 1’x4’ 4L sm wp 8 1’x4’ 4L sm wp 1 Inc. 2L exit sign 1 l’x4’x 2L sm wp 1 . l!x4’x 2L sm wp 12 1’x4’ 4L sm wp 2 8’ 4L Eggcrate DND 1 1’x4’ 4L sm wp 2 l’x4’x 2L sm wp 4 l’x4’x 2L sm wp 133 Lamp Lamp Type Hours City 2 FB40T12 4000 2 FB40T12 3500 2 F20T1220w 3500 2 FB40T12 3500 1 F30T12 3500 1 F40T12 34w 3500 2 F40T12 34w 3500 4 F40T12 34w 3500 2 Inc. 20w 8760 2 F40T12 34w 3500 4 F40T12 34w 3500 4 F40T12 34w 800 2 F40T12 34w 3500 4 F40T1234w 3500 4 F40T12 34w 3500 4 F40T12 34w 3500 2 Inc. 20w 8760 2 F40T12 34w 3500 2 F40T12 34w 3500 4 F40T12 34w 3500 4 F96T12 60w 3120 0 n/a 0 Proposed Conditions Retrofit Description 6 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 1 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 4 (2) F17T8 lamps, (1) 2L Ip elect bllst 14 (3) F17T8 lamp, (1) 2L Ipelect bllst, (1) rll 6 (1) F25T lamp, (1) 1L Ip elect bllst 6 (1) F32T8 lamp, (1) 1L Ip elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect bllst 16 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 LED exit sign w/bait backup when needed. 6 (2) F32T8 lamp, (.5) 4L nl elect bllst 19 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 9 (4) F32T8 lamp, (1) 4L Ip elect bllst 4 (4) F32T8 lamp, (1) 4L Ip elect bllst 8 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 LED exit sign w/bait backup when needed 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 New l’x8’x 4L wrap, w/(4) F32T8 lamps, (1) 4L Ip elect bllst 0 DND (items left as is) 4 F40T12 34w 3120 1 2 F40T12 34w 3120 2 2 F40T12 34w 3120 4 133 (4) F32T8 lamp, (1) 4L Ip elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 Cityof PaloAIto Landfill Employee Trailer- 2380 Embarcadero Road Existipg Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 2 Trailer #1 4 2’x4’x 4L rectrf 4 Lamp Type Hours Qty 4 F40T1234w 3120 4 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl Energy Masters International Page 1 City of Palo Alto Landfill Recycle Office Trailer - 2380 Embarcadero Road Existing Conditions Ref # Room # Qty Description Lamp Lamp Type Main Building - 1st Floor 1 Trailer #1 F40T1234w Hours 3120 2 RETROFIT SCOPE REPORT Proposed Conditions Retrofit De~scdption (2) F32T8 lamp, (!) 2L nl elect bllst, (1) rfl Energy Masters International Page 1 City of Palo Alto Landfill Storage & Equipment Bldg - 2380 Embarcadero Road RETROFIT SCOPE REPORT Existing Conditions Qty DescriptionRef#Room #Lamp Lamp Type Hours Qty Main Building - 1st Floor 3 Shed #1 1 l’x4’x 2L 2 F40T12 34w 1500 4 Shed #1 1 Inc. 2L par 2 Inc. 150w 4380 5 Shed #2 1 l’x4’x 2L 2 F40T12 34w 1500 3 Proposed Conditions Retrofit Description 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New HPS wall pack (1) 70w HPS lamp and ballast 1 (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Landfill Toll House - 2380 Embarcadero Road ¯ Ref #Room # Main Building - 1st Floor 6 Toll Building Existing Conditions City Description 8 2’x4’ 4L 8 Lamp Lamp Type F40T12 34w Hours 2500 8 RETROFIT.SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfi Energy Masters International -Page 1 City of Palo Alto Lawn Bowling Facility- Embarcadero and Cowper Ref #Room # Main Building - Ist Floor 1 card room 2 Meeting Room 3 kitchen 4 M RR 5 M RR 6 M RR ~¯ WRR 8 W RR 9 exterior 10 exterior Existing Conditions City Description 4 l’x4’x 2L sm wp 4 l’x4’x 4L sm wp 4 l’x4’x 2L sm wp 1 l’x4°x 2L hood 1 Inc. 1L bare bulb 1 l’x8’x 2L hood 1 l’x4’x 2L sm wp 1 i’x8’x 2L hood 2 Inc. 1Lvandal 2 l’x8’x 2L fxt .2-1 Lamp 2 4 2 2 1 2 2 2 1 .2 Lamp Type F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc. 60w F96T12 60w F40T12 34w F96T12 60w Inc. 60w F96T12 60w RETROFIT SCOPE REPORT Proposed Conditions Hours City Retrofit D~scription 2000 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 2000 4 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 2000 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 1 (1) CF 22w lamp and ballast 2000 1 (4) F32T8 lamp, (1) 4L Ip ~lect bllst, (1) bracket kit, (1) ballast pan 2000 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 1 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bFacket kit, (1) ballast pan 4380 2 (1) CF 15w lamps and ballast 4380 2 (4) F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit -21 Energy Masters International Page 1 City of Palo Alto Lucie Stern Community Center - 1305 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions .. Ref #Room #Qty Description Lamp Lamp Type aty Main Building - 1st Floor 1 Hall Entry 39 l’x4’x 2L WMwp 2 F40T12 34w 2 Hall Entry 1 Inc. 2L exit sign 2 Inc. 20w 3 Lobby 6 4’x4’ 4L sm box 4 F40T12 34w 4 Lobby 2 Inc. 2L exit sign 2 Inc. 20w 5 Stern Ballroom 6 Inc. 1L Chandlier 1 Inc. 300w 6 Stern Storage 1 l’x4’x 2L sm 2 F40T12 34w 7 Stern Storage 1 Inc. 2L exit sign 2 Inc. 20w 8 Cl Hall 3 l’x4’x 2L WM wp 2 F40T12 34w 9 Office #1 4 l’x4’x 2L sm 2 F40T12 34w 10 Copy Room 1 l’x4’x 2L sm 2 F40T12 34w 11 Office #2 ~l’x4’x 2L sm 2 F40T12 34w 12 Back Office 1 l’x4’x 2L sm 2 F40T12 34w 13 Office #3a 4 l’x4’x 2L sm 2 F40T12 34w 14 Office #3b 3 l’x4’x 2L sm 2 F40T12 34w 15 Office #4 4 l’x4’x 2L sm 2 F40T12 34w 16 Office #5 4 l’x4’x 2L sm 2 F40T12 34w 17 Men’s Restmom 1 l’x4’x 2L WM wp 2 F40T12 34w 18 Men’s Restroom 1 l’x4’x 2L sm 2 F40T12 34w 19 Men’s Restmom 1 Inc. 6L Vanity 6 Inc. 40w 20 Women’s Restroom 1 l’x4’x 2L WM wp 2 F40T12 34w 21 Women’s Restroom 1 l’x4’x 2L sm 2.F40T12 34w 22 Women’s Restroom 1 Inc. 6L Vanity 6 Inc. 40w 23 offce#6 12 l’x4’x2Lsm 2 F40T1234w 24 Community Room 3 Inc. 1L Chandlier 1 Inc. 300w 25 Community Room ’32 l’x4’x 2L strip 2 F40T12 34w 26 Kitchen 4 l’x4’x 2L sm 2 F40T12 34w 27 Kitchen 1 Inc. 1L Globe 1 Inc. 100w 28 Room D 1 Inc. 1L Chandlier 1 Inc. 300w 29 Room D 1 Inc. 1L Par 1 inc. 150w 30 Theatre Patio 6 Inc. 1L Par 1 Inc. 150w 31 Closet 1 Inc. 1L Globe 1 Inc. 100w 32 Stairwell 2 Inc. 1L rec Can 1 Inc. 100w 42 Community Theatre 5 Inc. 3L dome 3 Inc. 60w 43 Community Theatre 2 Inc. 2L exit sign 2 Inc. 20w 44 Women’s Restroom 2 Inc. 1L rec Can 1 Inc. 100w 45 Women’s Restroom 5 Inc. 1L dome 1 Inc. 60w 46 Men’s Restroom 4 Inc. 1L dome 1 Inc. 60w 47 Office #7 6 1’x4’ 4L sm wp 4 F40T12 34w 48 Office #7 1 Inc. 1L dome 1 Inc. 100w 49 Office #7 1 Inc. 2L exit sign 2 Inc. 20w 50 C. Theatre Hall #2 3 Inc. 1L dome 1 Inc. 100w 51 Green Room 4 1’x4’ 4L sm wp 4 F40T12 34w Proposed Conditions Hours Qty Retrofit Description 3500 39 (2) F32T8 lamp, (1) 2L nl elect bilst 8760 t LED exit sign w/bait backup when needed 3500 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 8760 2 LED exit sign w/bait backup when needed 2000 6 DND (items left as is) 2000 1 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 LED exit sign w/baft backup when needed 3500 3 (2) F32T8 lamp, (1) 2L nl elect blist 2500 - 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 . 1 (2) F32T8 lamp, (1) 2L nl elect bllst. 2500 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 4 (2) F32T8 lamp, (1) 2L nl elect bllst ¯ 2500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 New l’x2’x 2L vanity, w/(2) F17T8 lamps, (1) 2L Ip elect bllst 2500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 New l’x2’x 2L vanity, w/(2) F17T8 lamps, (1) 2L Ip elect bllst 2500 12 (2) F32T8 lamp, (t) 2L nl elect bllst 2500 3 DND (items left as is) 2500 32 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 (1) CF 22w lamp and ballast 2500 1 DND (items left as is) 2500 1 New HPS wall pack (1) 70w HPS lamp and ballast 4380 6 New HPS wall pack (1) 70w HPS lamp and ballast 800 1 (1) CF 22w lamp and ballast 8760 2 (1) CF 22w lamp and ballast 1200 5 New sm drum with (3) CF 15 watt lamps and ballast 8760 2 LED exit sign w/bait backup when needed 1200 2 (1) CF 22w lamp and ballast , 1200 5 New sm drum with (2) CF 15 watt lamps and ballast 1200 4 New sm drum with (2) CF 15 watt lamps and ballast 2500 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 2500 1 (1) CF 22w lamp and ballast 8760 1 LED exit sign w/bait backup when needed 1200 3 (1) CF 22w lamp and ballast 800 4 (4) F32T8 lamp, (1) 4L Ip elect bllst Energy Masters International Page ’1 City of Palo Alto Lucie Stern Community Center - 1305 Middlefield Road Existing Conditions Ref# Room# City Description Lamp Lamp Type 52 Makeup 0 NoAccess 0 n/a 53 Storage 1 Inc. 1L dome 1 inc. loow 54 Theatre Stage 0 DND 0 n/a 55 Theatre 8 Inc. 2L exit sign 2 Inc, 20w 56 Rehearshal Hall 0 DND 0 n/a 57 Costumes 0 DND 0 n/a 58 Hall 3 LED exit sign 1 LED 59 Box Office.2 l’x4’x 2L sm wp 2 F40T12 34w 60 Control Room 0 DND 0 n/a -61 Workshops 0 DND 0 n/a Basement 33 Basement Office 3 4’x4’ 8L 8 F40T12 34w 34 Basement Office 10 l’x4’x2Lwp 2 F40T1234w 35 .Basement Office 1 l’x4’x 1L sm wp 1 F40T12 34w 36 Basement Office 2 Inc. 2L exit sign 2 Inc. 20w 37 Storage #1 5 Inc. 4L Hood-4 Inc. 60w 38 Storage #1 1 l’x4’x 2L Vapor 2 F40T12 34w 39 Storage#2 2 Inc. 1LrecCan -1 Inc. 100w 40 Storage #2 2 4’x4’ 8L 8 F40T12 34w 41 Storage #3 2 l’x4’x 2L Vapor 2 F40T12 34w 228 Hour~ Q~y RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 800 0 DND (items left as is) 800 1 (1) CF 22w lamp and ballast 800 0 DND (items left as is) 8760 8 LED exit sign w/bait backup when needed 800 0 DND (items left as is) 800 0 DND (items left as is) .o 800 3 DND (items left as is) 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 0 DND (items left as is) 800 0 DND (items left as is) 2500 3 (8) F32T8 lamp, (2) 4L Ip elect bllst 2500 10 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 8760 2 LED exit sign w/batt backup when needed 800 5 (4) CF 15w lamps and ballast 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 2 (1) CF 22w lamp and ballast 800 2 (8) F32T8 lamp, (2) 4Lip elect bllst 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 228 Energy Masters International Page 2 City of Palo Alto Main Library - 1213 Newell Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 main room 407 l’x4’x 1L Luminous 1 2 main room stacks 164. l’x4’x 1L box 1 3 main room 6 Inc. 1L rec squares 1 4 main room 5 l’x 4’x 2L rec fxt 2 5 main room CF 1L rec can 1 6 lobby M R.R ..Inc. 1L custom can 1 7 MRR 1 Inc. lLrecsquares 1 8 MRR 1 l’xl’x2Lvanity 2 9 WRR 1 Inc. lLrecsquares 1 10 W RR 1 l’xl’x 2L vanity 2 11 staff room .._3_7l’x 4°x 2L rec fxt 2 12 DVD room 3 4’x4’x 4L fxt 4 13 Conference Room 2 4’x4’x 4L fxt 4 14 Library 3 4’x4’ 4L 4 15 Library Office 70 l’x4’x 1L Luminous 1 16 Library Break Room 4 l’x4’x 2L strip 2 17 Mail Room 4 l’x4’x 2L strip 2 22 extedor Inc. 1L par 1 23 exterior Inc. 2L par 2 24 extedor Inc. 1L rec can 1 Basement 18 Basement 66 l’xS’lLPMLouvre 1 19 Basement 1 1’x8’ 2L 2 20 Basement 17 Inc. lLOpen 1 21 Basement Computer 6 1’x8’ 1L PM Louvre 1 799 Lamp Lamp Type F40T12 34w F32T8 Inc. 100w F40T12 34w CF 15w Inc. 50w Inc. 75w F15T12 Inc. 75w F15T12 F40T12 34w .F32T8 F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w ¯ Inc. 150w Inc. 150w Inc. 60w F96T12 60w F96T12 60w Inc. 150w F96T12 60w Proposed Conditions Hours City Retrofit Description 4000 407 (1) F32T8 lamp, (.25) 4L Ip elect bllst 4000 164 DND (items left as is) 4000 6 (1) CF 22w lamp and ballast 4000 5 (2) F32T8 lamp, (1) 2L nlelect bllsl 4000 0 DND (items left as is) 4000 0 DND (items left as is) 4000 1 (1) CF 22w lamp and ballast 4000 1 DND (items left as is) 4000 1 (1) CF 22w lamp and ballast 4000 1 DND (items left as is) 4000 37 (2) F32T8 lamp, (1) 2L nl elect bllst 4000 3 DND (items left as is) 2500 2 (4) F32T8 lamp, (2) 2L dimming elect bllst 4000 3 (4) F32r8 lamp, (1) 4L Ip elect bllst 3120 70 (1) F32T8 lamp, (1) 1L Ip elect bllst , 3120 4 ¯ (2) F32T8 lamp, (1) 2L nl elect bllst 3120 4 (2) F32T8 lamp, (1) 2L nl elect bllst 4380 0 New HPS wall pack (1) 70w HPS lamp and ballast 4380 0 New HPS wall pack (1) 70w HPS lamp and.ballast 4380 0 (1) CF 22w lamp and ballast 2500 66 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) bracket kit 2500 1 (4) F32T8 lamp, (1) 4L Ip elect bllst,(1) bracket kit, (1) ballast pan 2500 17 DND (items left as is) 2500 6 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) bracket kit 799 Energy Masters International Page 1 City of Palo Alto Mitchell Park Clubhouse RR - 600 East Meadow RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 43 Men’s Restroom 44 Women!s Restroom 45 Exterior 46 Club Room 2 l’x4’x 2L Luminous 2 ¯ 2 l’x4’x 2L Luminous 2 4 l’x4’x 2L Luminous 2 6 CF 1L 1 14 Lamp Type F40T12 34w F40T12 34w F40T12 34w CF 15w Proposed Conditions Hours Qty Retrofit Description 8760 2 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4380 4 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 6 DND (items left as is) -o 14 Energy Masters International P~el City of Palo Alto Mitchell Park Comm Center - 3800 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref# Room # Qty Description Lamp Lamp Type Main Building - 1st Floor 1 Entry Lobby 0 HID 2 Entry Lobby 2 Inc. 2L exit sign 3 Main Hall 0 HID 4 Kitchen 4 l’x4’x 2L rec prsm 5 Hall next to Room 2 7 l’x4’x 2Lwp 6 Hall next to Room 2 1 Inc. 2L exit sign 7 Office 6 2x4’4L 8 Office1 4 lx4’x2Lwp 9 Office2 4 lx4’x2Lwp 10 Room1 8 2’x4’4L 11 Room2 12 2’x4’4L 12 Hall to Room 3 7 l’x4’x 2L wp 13 Hall to Room 3 1 Inc. 2L exit sign 14 Room3 8 2’x4’4L 15 Room 1 12 2’x4’ 4L. 16 Men’s Restroom 1 l’x4’x 2L wp 17 Men’s Restroom 1 Inc. 2L dome 18 Women’s Restroom 1 l’x4’x 2L wp 19 Women’s Restroom 1 Inc. 2L dome 20 Tumbling Room 0 DND 21 Tumbling Room 2 Inc. 2L exit sign 22 Storage 1 Inc. 1L PM Hood 23 Storage #2 2 Inc. 1L PM Hood 24 Exterior 27 Inc. 1L Square tt2 0 HID 2 Inc. 20w 0 HID 2 F40T12 34w 2 F40T12 34w 2 Inc. 20w 4 F40T12 34w 2 F40T12 34w 2 F40T12 34w 4 F40T12 34w 4 F40T12 34w 2 F40T12 34w 2 Inc. 20w 4 F40T12 34w 4 F40T12 34w 2 F40T12 34w 2 Inc. 60w 2 F40T12 34w 2 Inc. 60w 0 n/a 2 Inc. 20w 1 Inc. 100w 1 Inc. 100w 1 Inc. 100w Proposed Conditions Hours Qty Retrofit Description 4000 0 DND (items left as is) 8760 2 LED exit sign w! bait backup when needed 4000 0 DND (items left as is) 4000 4 (2) F32T8 lamp, (1) 2L nloelect bllst 4000 7 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 LED exit sign w/bait backup when needed 3120 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 3120 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 3120 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 4000 8 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 4000 12 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 7 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 LED exit sign w/halt backup when needed 4000 8 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 4000 12 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 1 New sm drum with (2) CF 15 watt lamps and ballast 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 1 New sm drum with (2) CF 15 watt lamps and ballast 800 0 DND (items left as is) 8760 2 LED exit sign w/bait backup when needed 800 1 (1) CF 22w lamp and ballast 800 2 (1) CF 22w lamp and ballast 4380 27 (1) CF 22w lamp and ballast 112 Energy Masters International Page 1 City of Palo Alto Mitchell Park Library - 3700 Middlefield Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Crime Prevention - 1st Floor 35 Bullpen 16 l’x4’x2Lrec 2 36 Bullpen 15 Inc. 1LSpots 1 37 Closet/Storage 1 l’x4’x 1L sm wp 1 38 Mechanical Room 1 l’x4’x 1L sm wp 1 Main Building - 1st Floor 25 Exterior Halls 9 Inc. 1L Square prsm 26 Main Library 5 l’x4’x 1Lsmwp 1 27 Main Library 39 l’x4’x2Lrec 2 28 Main Library 151 l’x4’x 2L Luminous 2 29 Men’s Restroom 1 l’x4’x 2L rec 2 30 Women’s Restroom 1 l’x4’x 2L rec 2 31 Staff 1 2’x2’ 2L 2 32 Staff 1 1’x4’ 4L 4 33 Staff Restroom 1 2’x2’ 2L 2 34 Staff Office 6 l’x4’x 21 rec 2 248 Lamp Type F40T12 34w Inc. 100w F40T12 34w F40T12 34w Inc. 100w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w FB40T12 F40T12 34w FEHOT12 F40T12 34w Proposed Conditions Hours Qty Retrofit Description 4000 16 (2) F32T8 lamp, (.5) 4L nl elect bllst 4000 15 (1) CF 22w lamp and ballast 800 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 800 1 (1) F32T8 lamp, (1) 1L Ipelect bllst 4380 9 (1) CF 22w lamp and ballast 4000 5 (1) F32T8 lamp, (1) 1L Ip elect bllst 4000 39 (2) F32T8 lamp, (1) 2L nl elect bllst 4000 151 (2) F32T8 lamp, (1) 2L nl elect bllst 3000 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3000 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 1 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 3120 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 1 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 3120 6 (2) F32T8 lamp, (.5) 4L nl elect bllst 248 Energy Masters International Page 1 City of Palo Alto Mitchell Park Tennis Center RR - 600 East Meadow RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 39 Restroom 40 Restroom 41 Restroom 42 Restroom 1 l’x4’x 2L rec Vapor 2 1 l’x4’x 2L re.c Vapor 2 1 l’x4’x 2L rec Vapor 2 1 l’x4’x 2L rec Vapor 2 4 Lamp Type F40T1234w F40T1234w F40T12 34w F40T1234w Proposed Conditions Hours Qty Retrofit Description 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 (2) F32T8 lamp, (1) 2L nlelect bllst 4 Energy Masters International Page 1 City of Palo Alto Municipal Services Center Bldg A - 3201 E. Bayshore Road Existing Conditions Ref# Room# Qty Description Lamp Lamp Type Hours Qty Building A - 1st Floor 1 Receiving 16 l’x4’x2Lsmwp 2 F40T1234w 3500 2 Extedor 4 l’x4’x 2L sm wp 2 F40T12 34w 4380 3 Canopy- Exterior 20 l’x4’x 2L sm wp 2 F40T12 34w 4380 4 Canopy-Fence 20 l’x4’x2Lsmwp 2,F40T1234w 4380 5 extedorMRR 2 l’x4’x2Lsmwp 2 F40T1234w 4380 6 extedor W RR 1 l’x4’x 2L sm wp 2 F40T12 34w 4380 7 Parks and Golf Open 10 l’x4’x2Lsmwp 2 F40T1234w 3120 8 Parks and Golf Open ~2 1’x4’ 4L sm wp 4 F40T12 34w 3120 9 parks and golf office 4 l’x4’x 2L sm wp.2 F40T12 34w 3120 10 parks and golf office 1 1’x4’ 4L sm wp 4 F40T12 34w 3120 1i hallway ._1.2’x4’x 4L sm box 4 F40T12 34w 3120 12 office#2 1 l’x4’x2Lsmwp 2.~F40T1234w 3120 13 office #3 2 2’x4’x 4L sm box 4 F40T12 34w 3120 14 phone room 1 1’x4’ 4L sm wp 4 F40T12 34w 800 15 main entry into A 1 1’x4’ 4L sm wp 4 F40T12 34w 3120 16 large open area 235 l’x4’x2Lsmhood 2 F40T1234w 3700 17 office#4 2 l’x4’x2Lsmwp 2 F40T1234w 3120 18 office#5 ’2 l’x4’x 2L sm wp 2 F40T12 34w 3120 325 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 16 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 20 (2) F32T8 lamp, (1) 2L nl elect bllst 20 (2) F32T8 lamp, (1) 2L nlelect bllst 2 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 .(2) F32T8 lamp,-(1) 2L nl elect bllst 10 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (4) F32T8 lamp, (1) 4L lp elect bllst 235 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 325 w500 WS WS ws ws Energy Masters International Page 1 City of Palo Alto Municipal Services Center Bldg B - 3201 E. Bayshore Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Lamp Type Hours City Building B - 1st Floor 19 Exterior Canopy 27 l’x4°x2Lsmwp 2 F40T1234w 4380 20 Tire Storage 48 l’x4’x 2L chn pm 2 F40T12 34w 2700 21 Bay 1 40 l’x4’x 2L sm wp 2 F40T12 34w 2700 22 Hall 3 l’x4’x 2L sm hood 2 F40T12 34w 2700 23 Storage 12 l’x4’x 2L chn pm 2 F40T12 34w 800 24 Office 2 l’x4’x 2L sm wp 2 F40T12 34w 3120 25 TruckBay2 168 l’x4’x2Lchnpm 2 F40T1234w 2700 26 Locked Storage 6 l’x4’x 2L chn pm 2 F40T12 34w 800 27 Office 12 l’x4’x2Lchnpm 2 F40T1234w 2200 28 Hall 19 l’x4’x2Lsmwp 2 F40T1234w 3120 29 Hall _1_Inc. 2L exit sign 2 Inc. 20w 8760 30 Colondries 2 2’x2’ 2L rec prsm 2 FB40T12 3120 31 Office 2 2’x2’ 2L rec prsm 2 FB40T12 3120 34 Downstairs 10 l’x4’x 1L sm strip 1 F40T12 34w 3120 35 Teleptype 0 No Access 0 n/a 3120 36 PaintShop 16 l’x4’x2Lchnpm 2 F40T1234w 3120 37 Copy Room 1 2’x4’ 4L 4 F40T12 34w 3120 38 Custodian 0 No Access 0 n/a 1500 39 Equipment 4 l’x4’x 2L sm wp 2 F40T12 34w 2200 40 Safety Office 2 " 2’x4’ 4L 4 F40T1234w 3120 41 Maintenance Shop-1 l’x4’x 2L sm wp 2 F40T12 34w 3500 42 Maintenance Shop-76 l’x4’x 2L chn pm 2 F40T12 34w 3500 43 Maintenance Shop-1 Inc. 2L exit sign 2 Inc. 20w 8760 44 Plan Room 4 2’x4’ 4L 4 F40T12 34w 3120 45 Plan Room Hall 1 l’x4’x 2L sm wp 2 F40T12 34w 3120 46 Office #1 2 l’x4’x 2L sm wp 2 F32T8 3120 47 Office#2 2 2’x4’4L 4 F40T1234w 3120 48 Office#3 2 l’x4’x2Lsmwp 2 . F40T1234w 3120 49 Break Room 1 2’x4’ 4L 4 F40T12 34w 3120 50 Storage ~2 2’x4’ 4L 4 F40T12 34w 3120 51 ’ Storage Room 0 No Access 0 n/a 800 52 Exercise Room Hall 2 l’x4’x 2L sm wp 2 F40T12 34w 3500 53 Exercise Room 9 l’x4’x 2L sm rec 2 F40T12 34w 3120 54 Office 2 l’x4’x 2L sm wp 2 F40T12 34w 3120 55 Storage 2 l’x4’x2Lsmwp 2 F40T1234w 3120 56 Communication 0 No Access 0 n/a 3120 57 Stairwell 17 l’x4’x2Lsmwp 2 F40T1234w 8760 58 Lunchroom-9 l’x4’x2Lsmwp 2 F40T1234w 3120 59 Upstairs Plan Room 1 4’x’4 4L 4 F40T12 34w 3120 60 ShowerRoom 2 l’x4’x2Lsmwp 2 F40T1234w 3120 61 Men’s Locker Room 3 l’x4’x 2L sm wp 2 F40T12 34w 3120 62 Men’s Restroom 4 l’x4’x 2L sm wp 2 F40T12 34w 3120 Energy Masters International Page 1 Proposed Conditions Retrofit Description 27 (2) F32T8 lamp, (1) 2L nl elect bllst 48 (2) F32T8 lamp, (.5) 4L nl elect bllst 40 (2) F32T8 lamp, (.5) 4L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl electbllst 168 (2) F32T8 lamp, (.5) 4L nl elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 19 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/batt backup when needed 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 10 (1) F32T8 lamp, (1) 1L Ip elect bllst 0 DND (items left as is) 16 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rtl 0 DND (items left as is) 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (2) F32T8 I.amp, (1) 2L nl elect bllst, (1) rfl 1 (2) F32T8 lamp, (1) 2L nl elect bllst 76 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 LED exit sign w/batt backup when needed 4 (2) F32T8 lamp, (1) 2L nl elect blist, (1) rfl 1 (2) F32T8 lamp, (1) 2L nl elect blist 2 DND (items left as is) 2 (2) F32T8 lamp, (1) 2L nl elect biist, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 0 DND (items left as is) 2 (2) F32T8 lamp, (1) 2L nl elect bllst 9 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2Lnl elect bllst 0 DND (items left as is) 17 (2) F32T8 lamp, (1) 2L nl elect bllst 9 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst WS WS WS WS WS W500 W500 City of Palo Alto Municipal Services Center Bldg B - 3201 E. Bayshore Road Existing Conditions Ref # Room # Qty Description Lamp 63 Facilities Rehab 3 l’x4’x 2L sm wp 2 64 Rehab Office #1 2 l’x4’x 2L sm wp 2 65 Rehab Office #2 4 l’x4’x 2L sm wp 2 66 Rehab Office #3 4 l’x4’x 2L ~m wp 2 67 Men’s Restroom 2.l’x4’x 2L sm wp 2 68 Women’s Restroom 2 l’x4’x 2L sm wp 2 69 Equipment Manger’s 2 l’x4’x 2L sm wp .2 70 Ox Storage 0 No Access 0 2nd Floor 32 Upstairs Warehouse 29 l’x4’x 2L chn pm 33 Office 3 2’x4’ 3L rec prsm 569 Lamp Type Hours Qty F40T12 34w 3120 F32T8 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 n/a 800 2 F40T1234w 3120 3 F40T1234w 3120 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 DND (items left as is) 4 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bilst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L ~lelect bllst 0 DND (items left as is) 29 3 569 (2) F32T8 lamp, (1) 2L nl elect bllst (3) F32T8 lamp, (1) 2L Ip elect bllst ws ws ws ws Energy Masters International Page 2 City of Palo Alto Municipal Services Center Bldg C 3201 E. Bayshore Road RETROFIT SCOPE REPORT Existing Conditions Ref# Room# Qbj Descdption Lamp Lamp Type Hours Qty Building C - 1st Floor 71 Exterior 25 l’x4’x 2L sm wp 2 72 electric meter shop 26 l’x4’x 2L sm hood 2 73 electric meter shop 1 l’x4’x 2L sm hood 2 74 electric meter shop 6 l’x4’x 2L sm hood 2 75 electric meter shop 3 2’x4;x 3L rec trf pblc 3 76 electric meter shop 2 l’x4’x 2L rec t~f pblc 2 77 ¯ main hallway 12 l’x4’x 2L sm hood 2 78 office nxt to meter 16 l’x4’x 2L sm hood 2 79 office nxt to meter 2 Inc. 2L exit sign 2 80 rubber goods 10 l’x4’x 2L sm hood 2 81 undergroung !8 l’x4’x 2L sm hood 2 82 overhead general 28 l’x4’x 2L sm hood 2 83 electric operations 12 2’x4’x 3L rec trf pblc 3 84 electric operations l’x4’x 2L rec trf pblc 2 85 electric operaions off 2 2’x4’x 3L rectrf pblc 3 86 electric operaions off 2 2’x4’x 3L rectrf pblc 3 87 electric operaions off 3 2’x4’x 3L rec trf pblc 3 88 undergound 8 l’x4’x 2L sm hood 2 89 elect operations gas 8 l’x4’x 2L sm hood 2 90 elect ops gas 7 2’x4’x 3L rectrf pblc 3 91 elect ops gas 3 l’x4’x 2L rec trf pblc 2 92 elec ops gas office 6 2’x4’x 2L rectrf 2 93 transformer shop 36 l’x4’x 2L sm wp 2 94 traffic signals 12 l’x4’x 2L sm hood 2 95 traffice signals rm #2 16 l’x4’x 2L sm hood 2 96 traffic signals 8 2’x4’x 4L rectrf 4 97 main hallway #2 43 l’x4’x 2L sm wp 2 98 main hallway #2 8 Inc. 2L exit sign 2 99 lanscape equipment 40 l’x4’x 2L sm wp 2 100 landscape 6 l’x4’x 2L sm wp 2 101 landscape 8 l’x4’x 2L sm wp 2 102 paintshop 15 l’x4’x3Lwmexp 3 103 - utilities WGW shop 56 l’x4’x 2L sm hood 2 104 utilities WGW shop 8 l’x4’x2Lsmstrip 2 105 sign shop 18 l’x4’x 2L sm hood 2 106 RR 1 l’x4’x 2L sm hood 2 107 gas meter shop 36 l’x4’x2Lsmhood 2 108 water meter shop 36 l’x4’x 2L sm hood 2 109 water meter shop 2 2’x4’x 4L rec trf 4 110 brushroom 36 l’x4’x2Lsmhood 2 111 storm drain shop 30 l’x4’x 2L sm hood 2 112 WRR 7 l’x4’x2Lsmhood 2 F40T12 34w 4380 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T1234w 3120 F40T1234w 3120 F40T1234w 3120 F40T12 34w 3120 Inc. 20w 8760 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T1234w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F32T8 3120 F40T1234w 3120 F40T1234w 3120 F40T1234w 3120 F40T1234w 3120 F40T12 34w ~120 Inc. 20w 8760 F40T1234w 3120 F40T12 34w 3120 F40~12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T1234w 3120 F40T1234w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T1234w 3120 F40T12 34w 3120 F40T12 34w 3120 F40T12 34w 3120 Energy Masters International Page 1 Proposed Conditions Retrofit Description 25 (2) F32T8 lamp, (1) 2L nl elect bllst 26 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (2) F32T8 lamp,_(1) 2L nl elect bllst 6 (2) F32T8 lamp, (.5) 4L nlelect bllst 3 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 16 (2) F32T8 lamp, (1) 2L nl elect bllst 2 LED exit sign w/batt backup when needed 10 (2) F32T8 lamp, (.5) 4L nl elect bllst 18.(2) F32T8 lamp, (.5) 4L nl elect bllst 28 (2) F32T8 lamp, (.5) 4L nl elect bllst 12 (3) F32T8 lamp, (1) 2L Ip elect bllst 0 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 3 (3) F32T8 lamp,.(1) 2L Ip elect bllst 8 (2) F32T8 lamp, (.5) 4L nl elect bllst 8 (2) F32T8 lamp, (.5) 4L nl elect bllst 7 (3) F32T8 lamp, (1) 2L Ip elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 6 DND (items left as is) 36 (2) F32T8 lamp, (.5) 4L nl elect bllst 12 (2) F32T8 lamp, (.5) 4L nl elect bllst 16 (2) F32T8 lamp, (1) 2L nl elect bllst 8 (2) F32T8 lamp, (.5) 4L nl elect bllst, (1) rfl 43 (2) F32T8 lamp, (1) 2L nl elect bllst 8 LED exit sign w/batt backup when needed 40 (2) F32T8 lamp, (.5) 4L nl elect bllst 6 (2) F32T8 lamp, (.5) 4L nl elect bllst 8 (2) F32T8 lamp, (.5) 4L nl elect bllst 15 (3) F32T8 lamp, (1) 2L Ip elect bllst 56 (2) F32T8 lamp, (1) 2L nl elect bllst 8 (2) F32T8 lamp, (1) 2L nl elect bllst 18 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 36 (2) F32T8 lamp, (.5) 4L nl elect bllst 36 (2) F32T8 lamp, (.5) 4L nl eiect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 36 (2) F32T8 lamp, (.5) 4L nl elect bllst 30 (2) F32T8 lamp, (.5) 4L nl elect bllst 7 (2) F32T8 lamp, (1) 2L nl elect bllst W500 City of Palo Alto Municipal Services Center Bldg C - 3201 E. Bayshore Road RETROFIT SCOPE REPORT Existing Conditions Ref #Room #Qty Description 113 WRR 114 hazordous waste 115 hazordous waste 116 Public Works bullpen 117 Public Works Office 118 Public Works Office t19 Public Works Office 120 Public Works Office 121 public works break 122 M RR 123 water and gas 124 water and gas 125 water & gas ops 126 water & gas ops 127.water & gas ops 128 water & gas ops 129 water & gas ops 130 water & gas ops 1 l’x 4’x 2L sm wp 5 2’x4’x 3L rec trf ~blc 2 2’x4’x 3L rec trf ~blc 21 2’x4’x 3L rec trf ~blc ¯ 1 2’x4’x 3L rec trf ~blc 1 2’x4’x 3L rec trf ~blc 2 2’x4’x 3L rec trf ~blc 2 2’x4’x 3L rec trf ~blc 3 2’x4’x 3L rec trf ~blc 24 l’x4’x 2L sm hood 12 2’x4’x 3Lrec trf ~blc 10 l’x4’x2Lrectrf ~blc 2 2’x4’x.3L rec trf ~blc 2 2’x4’x 3L rec tff ~blc 1 l’x4’x 2L rec trf ~blc 2 2’x4’x 3L rec trf Dblc 6 2’x4’x 3L rectrf 0blc 2 l’x4’x 2L rec trf 0blc 721 Lamp Lamp Type 2 F40T12 34w 3 F40T12 34w 3 F40T12 34w 3 F40T12 34w 3 F40T12 34w 3 F40T12 34w 3 F40T12 34w 3 F40T12 34w 3 F40T12 34w 2 F40T12 34w 3 F40T12 34w 2 F40T12 34w 3 F40T12 34w 3 F40T1-2 34w 2 F40T12 34w 3 F40T12 34w 3 F40T12 34w 2 F40T12 34w Proposed Conditions Hours City Retrofit Description 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 5 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 2 . (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 21 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 1 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 1 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 2 (3~) F32T8 lamp, (1) 2L I~-elect bllst 3120 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 3 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 24 (2) F32T8 lamp, (.5) 4L nl elect bllst 3120 12 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 10 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 6 (3) F32T8 lamp, (1) 2L Ip elect bllst 3120 2 (2) F32T8 lamp, (1) 2L nl elect bllst 72t ws ws w500 Energy Masters International Page 2 City of Palo Alto Municipal Services Center Scada Bldg - 3241 E. Bayshore Road RETROFIT SCOPE REPORT Existing Conditions Ref# Room# Qty Description Lamp Lamp Type Hours City Main Building - 1st Floor 1 Lobby 2 . 2’x4’ 3L rec prsm 2 Engineer Supply 2 2’x4’-3L rec prsm 3 Office #2 2 2’x4’ 3L re’c prsm 4 Office #3 2 2’x4’ 3L rec prsm 5 Conference 7 . 2’x4’ 3L rec prsm 6 Off.ice #5 2 2’x4’ 3L rec prsm 7 Office #4 2 2’x4’ 3L rec prsm 8 Control Room 0 DND 9 . Hall 9 l’x4’x 2L sm 10 Lobby 5 Inc. 2L exit sign 11 Office #8 2 2’x4’ 3L rec prsm 12 Office #9 2 2’x4’ 3L rec prsm 13 Electrical Room 4 l’x4’x 2L sm hood 14 Fire Panel Room 8 2’x4’ 3L rec prsm 15 Janitor Room 1 l’x4’x 2L sm 16 Mechanical Room 4 l’x4’x 2L sm hood 17 Men’s Restroom 2 l’x4’x2L sm 18 Men’s Restroom 1 l’x4’x 1L sm wp 19 Women’s Restroom 2 l’x4’x 2L sm 20 Women’s Restroom 1 l’x4’x 1L sm wp 60 3 F40T12 34w 8760 3 F40T12 34w 3120 3 F40T12 34w 3120 3 F40T12 34w 3120 3 F40T12 34w 3120 3 F40T12 34w 3120 3 F40T12 34w 3120 0 n/a 8760 2 F40T12 34w 8760 2 Inc. 20w 8760 3 F40T12 34w 3120 3 F40T12 34w 3120 2 F40T12 34w 1500 3 F40T12 34w 1500 2 F40T12 34w 800 2 F40T12 34w 800 2 F40T12 34w 8760 1 F40T12 34w 8760 2 F40T12 34w 8760 1 F40T12 34w 8760 Proposed Conditions Retrofit Description 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip-elect bllst 7 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 0 DND (items left as is)"9 (2) F32T8 lamp, (1) 2L nl elect bllst 5 LED exit sign w/balt backup when needed 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst. 8 (3) F32T8 lamp, (1) 2L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 60 ws ws ws ws Energy Masters International Page 1 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # City Description Main 1 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 27 28 2~ 3O 31 32 33 35 36 37 38 39 40 41 42 Building - 1-Private Office 7 CF 1L cn fxt 2-Private Office 2 2’x4’x 2L rec trf 3-Fingerprints 1 l’x4’x 2L sm wp 4-Private Office 1 l’x4’x 2L sm wp 5-Private Office 2 2’x4’x 2L rec trf 6-Hallway 1 CF 1L cn fxt 6-Hallway 1 CF 2L exit sign ss 6-Hallway 12 2’x4’x 2L rec trf 7-Private Office 1 2’x4’x 2L rec trf 8-Private Office 2 2’x4’x 2L rec trf 9-Restroom 2 Inc. 1L wm jj 10-Restroom 2 Inc. 1L wm jj 11-Private Office 2 2’x4’x 2L rec Irf 12-Private Office 2 2’x4’x 2L rec trf 13-Private Office 2 2’x4’x 2L rec trf 14-Private Office 4 2’x4’x 3L rec trf 15-Private Office 2 2’x4’x 2L rec trf 16-Conference 4 2’x4’x 2L rec trf 17-Private Office 2 2’x4’x 2L rec Irf 18-Private Office 2 2’x4’x 2L rec trf 19-Private Office 2 2’x4’x 2L rec trf 20-Private Office 2 2’x4’x 2L rec lrf ¯ 21-Private Office 6 2’x4’x 2L rec trf 22-Open Office 3 2’x4’x 2L rec trf 23-Open Office 4 2’x2’x 2L rectrf 24-Open Office 2 2’x2’x 2L rec trf 24-Open Office 1 2’x4’x 2L rec trf 25-Open Office 15 4’x4’x 4L sm wp 26-Women’s 2 Inc. 1L rec can 26-Women’s 2 l’x4’x 2L wm wp 27-Janitorial Closet 1 Inc. 1L wm keyless 28-Men’s Restroom 2 Inc. 1L rec can 28-Men’s Restroom 1 l’x4’x .2L wm wp 29-Copy Room 1 l’x4’x 2L sm wp 30-Private Office 2 2’x4’x 2L rectrf 31-Private Office 4 2’x4’x 2L rec trf 32-Private Office 1 2’x2’x 2L rectrf 32-Private Office 2 2’x4’x 2L rec trf 32-Private Office 1 2’X4’X 2L rectrf 33-Hallway 2 2’x4’x 2L rectrf 34-Hallway 3 2’x4’x 2L rectrf 35-Hallway 2 2’x4’x 2L rectrf Lamp Lamp Type Hours City ¯ 1 CF 18w 4200 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 1 CF 18w 5000 2 CF 7w 8760 2 F40T12 34w 5000 2 F40T12 34w 3700 2 F40T12.34w 3700 1 Inc. 75w 2600 1 Inc. 75w 2600 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 3 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 4200 2 F40T12 34w 4200 2 FB40T12 4200 2 FB40T12 4200 2 F40T12 34w 4200 4 F32T8 4200 1 Inc. 150w 2600 2 F40T12 34w 2600 1 Inc. 90w 800 1 Inc. 150w 2600 2 F40T12 34w 2600 2 F32T8 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 FB40T12 3700 2 F40T12 34w 3700 2 F40T12 34w.3700 2 F40T12 34w 5000 2 F40T12 34w 5000 2 F40T12 34w 5000 Proposed Conditions Retrofit Description 7 DND (items left as is) 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L hi-elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 DND (items left as is) 1 LED exit sign w/batt backup when needed 12 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (1).CF 15w lamps and ballast 2 (1) CF 15w lamps and ballast ¯ 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4’(3) F32T8 lamp, (1) 2L & (1) 1L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect bllst. 3 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 1 (2) F32T8 lamp, (1) 2L nl elect bllst 15 DND (items left as is) 2 (1) CF 42w lamp and ballast 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) CF 15w lamps and ballast, globe 2 (1) CF 42w lamp and ballast 1 (2)F32T8 lamp, (1) 2L nl elect bllst 1 DND (items left as is) 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # City Description Lamp 43 36-Hallway 7 2’x4’x 2L rec trf 2 44 36-Hallway 2 Inc. 1L rec can 1 45 37-Private Office 2 2’x4’x 2L rec trf 2 46 38-Private Office 2 2’x4’x 2L mc Iff 2 47 39-Conference 8 2’x4’x 2L mc In’2 48 40-Private Office 2 2’x4’x 2L mc trf 2 49 41-Private Office 2 2’x4’x 2L mc tn’2 50 42-Private Office 2 2’x4’x 2L rec In’2 51 43-Private Office 2 2’x4’x 2L rec trf 2 52 44-Pri~ate Office 2 2’x4’x 2L rec In’2 53 45-Open Once 5 2’x4’x 2L rec trf 2 54 46-Private Office 1 l’x4’x 2L sm wp 2 55 47-Private Office 1 .l’x4’x 2L sm wp 2 56 ¯ 48-Restmom 2 Inc. 1Lwmjj 1 57 49-Restroom 2 Inc. 1Lwm jj 1 58 50-Private Office 6 2’x4’x 2L mc tn’2 59 51-PrivateOffice 2 2’x4’x 2L rec trf 2 60 52-Pdvate Office 2 2’x4’x 2L rectrf 2 61 53-Private Office 2 2’x4’x 2L rec trf 2 62 54-Private Office 2 2’x4’x 2L rec trf 2 63 55-Open Office 9 CF 1L cn fxt 1 64 55-Open Office 2 2’x4’x 2L rec in’2 65 56-Council 5 CF 2L exit sign ss 2 66 56-Council 165 Inc. 1L rec can 1 67 57-Entry 2 CF 2L exit sign ss 2 68 57-Entry 1 2’~(4’x 4L rec in’ pblc 4 69 57-Entry 16 CF1Lcnfxt 1 70 57-Enlry 2 2’x2’x 2L rec trf 2 71 58-Entry 2 Inc. 1L rec can 1 72 58-Entry 2 2’x4’x 2L rec tn’2 73 59-Main Lobby 3 Inc. 1L rec can 1 74 59-Main Lobby 3 Inc. 1L rec can 1 75 60-Revenue 19 2’x4’x 2L rec Irf 2 76 61-Open Office 8 2’x4’x 2L mc tn’2 77 62-Private Office 2 2’x4’x 2L mc trf 2 78 63-Private Office 2 2’x4’x 2L mc In’2 79 64-Private Office 2 2’x4’x 2L mc trf 2 80 65-Hallway 3 CF 1L cn fxt 1 81 66-Elevator Lobby 3 CF 1L cn fxt 1 82 . 66-Elevator Lobby 2 t’xS’x 1L rec strip 1 83 66-Elevator Lobby 1 l’x4’x 1L rec strip 1 84 67-Conference 12 l’x8’x 2L pm strip 2 85 67-Conference 12 l’x4’x 1L pm strip 1 86 67-Conference 9 Inc. 1L rec can 1 Lamp Type Houm Qty F40T12 34w 5000 Inc. 150w 5000 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 4200 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 4200 F32T8 3700 F32T8 3700 Inc. 75w 2600 Inc. 75w 2600 F40T12 34w 4200 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 CF 18w 4200 F40T12 34w 4200 CF 7w 8760 Inc. 150w 1500 CF 7w 8760 F32T8 4500 CF 18w 4500 FB40T12 4500 Inc. 150w 4500 F40T12 34w 4500 Inc. 150w 4500 Inc. 300w 4500 F40T1234w 4200 F40T12 34w 4200 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 CF 18w 5000 CF 18w 8760 F96T12 HO 8760 F48T12 HO 8760 F32T8 4200 F32T8 4200 Inc. 50w 4200 7 2 2 2 8 2 2 2 2 2 5 1 1 2 2 6 2 2 2 2 9 2 5 165 2 1 16 2 2 2 3 3 19 8 2 2 2 3 3 2 1 12 12 9 Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst (1) CF 42w lamp and ballast (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T6 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L fil i~lect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst DND (items left as is) DND (items left as is) (1) CF 15w lamps and ballast (1) CF 15w lamps and ballast (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst DND (items left as is) (2) F32T8 lamp, (1) 2L nl elect bllst LED exit sign w/batt-backup when needed DND (items left as is) LED exit sign w/batt backup when needed DND (items left as is) DND (items left as is) (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl (1) CF 42w lamp and ballast (2) F32T8 lamp, (1) 2L nl elect bllst DND (items left as is) DND (items left as is) (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst DND (items left as is) DND (items left as is) (1) F96T8 HO lamp, (1) 1L HO elect bllst (1) F32T8 lamp, (1) 1L nl elect bllst DND (items left as is) DND (items left as is) (1) CF 15w lamps and ballast, ieflective housing Energy Masters International Page2 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave. Existing Conditions Ref # Room # Qty Description Lamp 87 68-Men’s Restroom 2 Inc. 1L rec can 1 88 ,, 68-Men’s Restroom 2 l’x4’x 2L wm wp 2 89 69-Women’s 2 Inc. 1L rec can 1 90 69-Women’s 2 l’x4’x 2Lwm wp 2 91 70-Open Office 12 2’x4’x 2L rec trf 2 92 71-Private Office 2 2’x4’x 2L rec trf 2 93 72-Private Office 2 2’x4’x 2L rec trf 2 94 73-Private Office 2 2’x4’x 2L rec trf 2 95 74-Copy Area 2 l’x3’x 2Lwm wp 2 96 75-Copy Room 1 l’x8’x 2L sm strip 2 97 76-File Room 1 l’x4°x 1L sm strip 1 98 76-File Room 1 2’x4’x 2L rectrf 2 99 77-Conference 4 2’x4’x 3L rec trf pblc 3 100 77-Conference 6 2’x4’x 4L rectrf 4 101 78:Restroom 1 l’x4’x 2L rec strip 2 102 79-Restroom 1 l’x4’x 2L rec strip 2 103 80-Hallway 2 l’x4’x.2Lsmwp 2 104 80-Hallway 1 2’x4’x 4L rectrf 4 105 80-Hallway 2 CF1Lcnfxt 1 106 El-Elevator 2 l’x3’x 1L sm strip 1 107 El-Elevator 2 l’x6’x2Lfxt 2 108 El-Elevator 1 l’x2’x 2L sm strip 2 109 E2-Elevator 2 l’x2’x 2L sm strip 2 110 E2-Elevator 2 l’x3’x 1Lsm strip 1 111 E2-Elevator 2 l’x4’x 1L sm strip 1 112 E3-Elevator 4 l’x3’x 1L sm strip 1 113 SWl-Stairwell (West)1 CF 2Lexit sign ss 2 114 . SW1-Stairwell (West)8 l’x4’x 1L wm wrap 1 115 SWA-Stairwell Alcove 1 l’x4’x 2L sm stdp 2 116 SWl-Stairwell(West)11 l’x4’x2Lwmwp 2 117 SWA-Stairwell Alcove 1 CF 2L exit sign ss 2 118 119 120 121 122 123 124 125 126 127 128 129 1-Customer Service l-Open Office 2-Private Office 3-0 ~en Office 3-0 ~en Office 4-0 ~en Office 5-0 ~n Office 6-O ~en Office 7-O ~n Office 7-O)en Office 8-0 ~en Office 9-0 3en Office 22 2’x4’x 2L rec trf 1 CF 2L exit sign ss 2 2’x4’x 2L rec trf 10 2’x4’x 2L rec trf 2 2’x2’x 2L rec trf 9 2’x4’x 2L rec trf 3 2’x4’x 2L rec trf 4 2’x4’x 2L rec trf 1 CF 2L exit sign ss 6 2’x4’x 2L rec trf 7 2’x4’x 2L rec trf 4 2’x4’x 2L rec trf Energy Masters International Lamp Type Hours Inc. 150w 2600 F40T12 34w 2600 Inc; 150w 2600 F40T12 34w 2600 F40T12 34w 4200 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F30T12 25w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 4200 F32T8 2600 F32T8 2600 F40T12 34w 6000 F40T12 34w 6000 CF 18w 5000 F30T12 25w 8760 F30T12 25w 8760 F20T12 20w 8760 F20T12 20w 8760 F30T12 25w 8760 F40T12 34w~ 8760 F30T12 25w 8760 CF 7w 8760 F40T12 34w 8760 F40T12 34w 8760 F40T12 34w 8760 CF 7w 8760 2 F40T12 34w 4200 2 CF7w 8760 2 F40T1234w 3700 2 F40T12 34w 4200 2 FB40T12 4200 2 F40T12 34w 4200 2 F40T1234w 4200 2 F40T1234w 4200 2 CF7w 8760 2 F40T1234W 4200 2 F40T12 34w 4200 2 F40T12 34w 4200 Page3 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description 2 New 9’ ~n with 2) 15w CF lamps 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 New 9’ can with 2) 15w CF lamps 2 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L ~l-elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F25T lamps, (1) 2L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 1 (2) F32T8 lamp,-(1) 2L nl elect bllst 4 (3) F32T8 lamp, (1) 2L Ip elect bllst 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 DND (items left as is) 1 DND (items left as is) 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 DND (items left as is) 2 (1) F25T lamp, (1) 1L Ip elect bllst 2 (2) F25T lamps, (1) 2L Ip elect bllst 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 (1) F25T lamp, (1) 1L Ip elect bllst 2 (1) F32T8 lamp, (1) 1L Ip elect bllst 4 (1) F25T lamp, (1) 1Llp elect bllst 1 LED exit sign w/bait backup when needed 8 (1) F32T8 lamp, (1) 1L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 11 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/bait backup when needed 22 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/bait backup when needed 2 (2) F32T8 lamp, (1) 2L nl elect bllst 10 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 9 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/bait backup when needed 6 (2) F32T8 lamp, (1) 2L nl elect bllst 7 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp t30 10-Open Office 4 2’x4’,x 2L rec trf 2 131 11-Private Office 2 2’x4’x 2L rec trf 2 132 12-PdvateOffice 2 2’x4’x2Lrectrf 2 133 13-Storage 2 2’x4’x2Lrectrf 2 134 14-Storage 1 l’x3’x 1Lsm strip 1 135 15-Storage 1 l’x3’x 1L sm stdp 1 136 16-Storage 1 l’x3’x 1L sm strip 1 137 17-Open Office 12 2’X4’x2Lrectrf 2 138 18-Computer Room 9 2’x4’x 2L rec tff 2 139 19-Computer Room 2 2’x4’x 2L rec t~f 2 140 20-Computer Room 4 2’x4’x 2L rec trf 2 141 21-Computer Room 1 2’x4’x2L rec trf 2 ¯ 142 22-Men’s Restroom 2 Inc. 1L rec can 1 143 22-Janitorial Closet -1 Inc. 1Lwm keyless 1 144 22-Men’s Restroom 2 l’x4’x 2L wm wp 2 145 , 23-Women’s 1 l’x4’x 2L wm wp 2 146 23-Women’s 1 l’x3’x2Lwmwp 2 147 23-Women’s 2 Inc. 1Lreccan 1 148 24-Elevator Lobby 5 CF 1L cn fxt 1 149 24-Elevator Lobby 2 l’x8’x 1L tec strip 1 150 24-Elevator Lobby 1 l’x4’x 1L rec strip 1 151 SWA-Stairwell Alcove 1 CF 2L exit sign ss 2 152 SWA-Stairwell Alcove 1 l’x4’x 2L sm strip 2 Lamp Type F40T1234w F40T12 34w F40T1234w F40T1234w F30T1225w F30T1225w F30T1225w F40T1234w F40T1234w F40T1234w F40T1234w F40T1234w Inc. 150w Inc.90w F40T1234w F40T1234w F30T1225w Inc. 150w CF 18w F96T12 HO F48T12 HO CF7w F40T1234w Proposed Conditions Hours Qty Retrofit Description 4200 4 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (1) F25T lamp, (1) 1L Ip elect bllst 800 1 (1) F25T lamp, (1) 1L Ip elect bllst 800 1 . (1) F25T lamp, (1) 1L Ipelect bllst 4200 12 (2) F32T8 lamp, (1) 2L nl elect bllst 4200 9 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 4 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2600 2 (1) CF 42w lamp and ballast 800 1 (1) CF 15w lamps and ballast, globe 2600 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2600 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2600 1 (2) F25T lamps, (1) 2L Ip elect bllst 2600 2 (1) CF 42w lamp and ballast 8760 5 DND (items left as is) 8760 2 (1) F96T8 HO lamp, (1) 1L HO elect bllst 8760 1 (1) F32T8 lamp, (1) 1L nl elect bllst 8760 1 LED exit sign w/batt backup when needed 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3 160 1-Elevator Lobby 5 CF 1L cn fxt 1 CF 18w 8760 161 1-Elevator Lobby 2 l’x8’x 1L rec strip t F96T12 HO 8760 162 1-Elevator Lobby.1 l’x4’x 1L rec strip 1 F48T12 HO 8760 169 2-J~nitorial Closet 1 Inc. 1L wm keyless 1 Inc. 90w 800 171 2-Men’s Restroom 2 Inc. 1L rec can 1 Inc. 150w 2600 172 2-Men’s Restroom 1 l’x3’x 2L wm wp 2 F30T12 25w 2600 173 2-Men’s Restroom 1 l’x4’x 2L wm wp 2 F40T12 34w 2600 177 3-Ulility Marketing 35 2’x4’x 2L rec trf pblc 2 F32T8 4200 183 3-Open Office 1 CF 2L exit sign ss 2 CF 7w 8760 ¯ 184 3-OpenOffice 2 2’x2’x2Lrectrfpblc 2 F17T8 4200 186 3-Open Office 3 CF 1L cn fxt 1 CF 18w 4200 187 3A-Women’s 2 Inc. 1L rec can 1 Inc. 150w 2600 188 3A-Women’s 1 l’x3’x2Lwmwp 2 F30T1225w 2600 189 3A-Women’s 1 l’x4’x2Lwmwp 2 F40T1234w 2600 190 4-Open Office 8 2’x4’x 2L rec tff pblc 2 F32T8 4200 191 5-Storage 2 2’x4’x2Lreclffpblc .2 F32T8 800 192 6-Computer Room 2 2’x4’x 2L rec trf pblc 2 F32T8 3700 193 . 7-Open Office 11 2’x4’x 2L rec trf pblc 2 F32T8 ~ 4200 194 8-Private Office 4 2’x4’x 2L rec trf pblc 2 F32T8 3700 195 9-Hallway 4 CF1Lcnfxt 1 CF22w 5000 DND (items left as is) (1) F96T8 HO lamp, (1) 1L HO elect bllst (1) F32T8 lamp, (1) 1L nl elect bllst (1) CF 15w lamps and ballast, globe - New 9" can with 2) 15w CF lamps (2) F25T lamps, (1) 2L Ip elect bllst (1) F32T8 lamp, (1) 1L nl elect bllst DND (items left as is) LED exit sign w/batt backup when needed DND (items left as is) DND (items left as is) New 9’ can with 2) 15w CF lamps (2) F25T lamps, (1) 2L Ip elect bllst (1) F32T8 lamp, (1) 1L nl elect bllst DND (items left as is) DND (items left as is). DND (items left as is) DND (items left as is) DND (items left as is) DND (items left as is) Energy Masters International Page 4 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description 196 10-Copy Room 197 11-Conference 198 12-Open Office 199 . 12-Open Office 200 13-Open Office 201 SWA-Stairwell Alcove 202 SWA-Stairwell Alcove 4 163 14-Elevator Lobby 164 14-Elevator Lobby 167 14-Elevator Lobby 203 1-Open Office 204 1-Open Office 205 1-Open Office 206 2-Open Office 207 3-Open Office 208 4-Storage 209 5-Open Office 210 5-Open Office 211 6-Open Office 212 7-Conference Room 213 7-Conference Room 214 8-Open Office 215 8-Open Office ¯ 216 9-Private Office 217 10-Private Office 218 11-Open Area 219 12-Men’s Restroom 220 12-Men’s Restroom 221 . 12-Janitorial Closet 222 12.Men’s Restroom 223 13-Women’s 224 13-Women’s 225 SWA-Stairwell Alcove 226 SWA-Stairwell Alcove 5 158 1-Elevator Lobby 159 1-Elevator Lobby 166 1-Elevator Lobby 168 2-Men’s Restmom 170 2-Men’s Restmom 175 3-Women’s 176 3-Women’s 182 3-Women’s Lamp Lamp Type Hours Qty 3 2’x4’x 2L rec tff pblc 2 F32T8 3700 1 l’xS’x 4L pm ind/dlr 4 F59T8 3700 1 CF 2L exit sign ss 2 CF 7w 8760 15 2’x4’x 2L rec.trf pblc 2 F32T8 4200 8 2’x4’x 2L rec trf pblc 2 F32T8 4200 1 l’x4’x 2L sm strip 2 F40T12 34w 8760 1 CF 2L exit sign ss 2 CF 7w 8760 5 CF1Lcnfxt 2 l’x8’x 1L rec strip. 1 l’x4’x 1L rec strip 1 2’x2’x 2L rec trf pblc 1 CF 2L exit sign ss I2 2’x4’x 3L rec tff }blc 16 2’x#x3Lrectrf }blc 11 2’x4’x 3L rec lrf }blc " 2 2’x4’x 3L rec tff )blc 3 2’x2’x 2L rec tff }blc 10 2’x4’x 3L rec trf )blc 1 2’x2’x 2L rectff )blc 4 2’x4’x 3L rec tff )blc 1 l’x4’x 1L wm wrap 1 . CF 2L exit sign ss 7 2’x4’x 3L rec tff pblc 2 2’x4’x 3L rec trf pblc 2 2’x4’x 3L rec trf pblc 12 2’x4’x 3L rec trf pblc ¯ 1 l’x2’x 1L wm strip 1 l’x4’x 1 L wm wrap 1 l’x2’x 1L wm stdp 2 2’x2’x 2L rec trf 1 l’x4’x 1L wm wrap 2 2’x2’x 2L rectrf 1 l’x4’x 2L sm strip 1 CF 2L exit sign ss 5 CF 1Lcn fxt 2 l’x8’x 1L rec stdp 1 l’x4’x 1L rec strip 1 l’x3’x 2L wm wp 2 Inc. 1Lreccan 1 l’x3’x 2L wm wp 2 Inc. 1L rec can 1 l’x4’x 2L wm wp 1 CF 18w 8760 1 F96T12 HO 8760 1 F48T12 HO 8760 2 FB40T12 4200 2 CF7w 8760 3 F40T1234w 4200 3 F40T1234w 4200 3 F40T1234w 4200 3 F40T1234w 800 2 FEHOT12 4200 3 F40T1234w 4200 2 FB40T12 4200 3 F40T1234w 3700 1 F40T1234w 3700 2 CF7w 8760 3 F40T1234w 4200 3 F40T1234w 3700 3 F40T12 34w 3700 3 F40T12 34w 4200 1 F20T1220w 2600 1 F40T12 34w 2600 1 F20T1220w 800 2 FB40T12 2600 1 F40T12 34w 2600 2 FB40T12 2600 2 F40T1234w 8760 2 CF7w 8760 11 CF 18w 8760 1 F96T12 HO 8760 1 F48T12 HO 8760 2 F30T1225w 2600 1 Inc. 150w 2600 2 F30T1225w’ 2600 1 Inc. 150w 2600 2 F40T1234w 2600 Proposed Conditions Retrofit Description 3 DND (items left as is) 1 DND (items left as is) 1 LED exit sign w/batt backup when needed 15 DND (items left as is) 8 DND (items left asis) 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/batt backup when needed 5 DND (items left as is) 2 (1) F96T8 HO lamp, (1) 1L HO elect bllst 1 (1) F32T8 lamp, (1) 1L nl elect bllst 1 (2) F17T8 lamp, (1) 2L nl elect bllst, (1) rfl 1 LED exit sign w/batt backup when needed 12 (3) F32T8 lamp, (1) 2L Ip elect bllst 16 (3) F32T8 lamp, (1) 2L Ip elect bllst 11 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 3 (2) F17T8 lamp, (1) 2L nl elect bllst, (1) rfl 10 (3) F32T8 lamp, (1) 2L Ip elect bllst 1 (2) F17T8 lamp, (1) 2L nl elect bllst, (1) rfl 4 (3) F32T8 lamp, (1) 2L Ip elect bllst 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 1 LED exit sign w/batt backup when needed 7 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2LIp elect bllst 12 (3) F32T8 lamp, (1) 2L Ip elect bllst 1 (1) F17T8 lamp, (1) 1L Ip elect bllst 1 " (1) F32T8 lamp, (1) 1L Ip elect bllst 1 (1) F17T8 lamp, (1) 1L Ip elect bllst 2 (2) F17T8 lamp, (1) 2L nl elect bllst, (1) rfl 1 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 (2) F17T8 lamp, (1) 2L nl elect bllst, (1) dl 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/batt backup when needed 5 DND (items left as is) 2 (1) F96T8 HO lamp, (1) 1L HO elect bllst 1 (1) F32T8 lamp, (1) 1L nl elect bllst 1 (2) F25T lamps, (1) 2L Ip elect bllst 2 New 9’ can with 2) 15w CF lamps 1 (2) F25T lamps, (1) 2L Ip elect bllst 2 New 9’ can with 2) 15w CF lamps 1 (1) F32T8 lamp, (1) 1L nl elect bllst Energy Masters Intemational Page 5 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244. 245 6 153 156 157 174 178 185 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 . Existing Conditions Ref # Room # Qty Description Lamp 4-Open Office 12 2’x4’x 2L rec trf 2 4-Open Office 1 CF 2L exit sign ss 2 5-Private Office 2 2’x4’x 2L rec trf 2 6-Private Office 2 2’x4’x 2L rec trf 2 7-Open Office 21 2’x4’x 2L rec trf 2 8-Open Office 21 2’x4’x 2L rectrf 2 9-Open Office 5 2’x4’x 2L rectff 2 10-Private Office 2 2’x4’x 2L rec trf 2 11-Private Office 2 2’x4’x 2L rec trf 2 12-Break Room 3 2’x4’x 2L rec trf 2 13-Conference 4 2’x4’x 2L rec trf 2 14-Private Office 4 2’x4’x 2L rec Irf 2 15-Private Office 2 2’x4’x 2L rec trf 2 16-Open Office 1 CF 2L exit sign ss 2 16-Open Office 4 CF 1L cn fxt 1 16-Open Office 9 2’x4’x 2L rec trf 2 17-Open Office 16 2’x4’x 2L rec trf 2 SWA-StainNell Alcove 1 CF 2L exit sign ss 2 SWA-Stairwell Alcove 1 l’x4’x 2L sm strip 2 1-Elevator Lobby 1-Elevator Lobby 1-Elevator Lobby 3-Women’s 3-Women’s 3-Women’s 4-Open Office 4-Open Office 5-Open Office 6-Private Office 7-Private Office 8-Private Office 9-Private Office 10-Private Office 11-Hallway 12-Private Office 13-Private Office 14-Private Office 15-Private Office 16-Open Office 16-Open Office 17-Private Office 18-Private Office 19-Private Office 5 CF 1Lcn fxt 2 l’x8’x 1L rec stdp 1 l’x4’x 1L rec strip 1 l’x4’x 2L wm wp 1 l’x3’x 2L wm wp 2 Inc. 1Lreccan 24 2’x4’x 2L rec lrf pblc 1 CF 2L exit sign ss i4 2’x4’x2Lrectrf )blc 2 2’x4’x 2L rectrf )blc 2 2’x4’x 2L rectrf ~blc 3 2’x4’x 2L rec trf ~blc 2 ’ 2’x4’x 2L rec trf )blc 2 2’x4’x 2L rec trf )blc 2 2’x4’x 2L rectrf ~blc 3 2’x4’x 2L rec trf ~blc 3 2’x4’x 2L rec trf ~blc 2 2’x4’x 2L rec trf )blc 3 2’x4’x 2L rec trf )blc 10 2’x4’x 2L rec Irf )blc 1 CF 2L exit sign ss 2 2’x4’x 2L rec Irf pblc 3 2’x4’x 2L rec tff pblc 2 2’x4’x 2L rec trf pblc Lamp Type Hours Qty F40T12 34w 4200 CF 7w 8760 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 4200 F40T12 34w 4200 F40T12 34w 4200 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 CF 7w 8760 ~ CF 18w 4200 F40T12 34w 4200 F40T12 34w 4200 CF 7w 8760 F40T12 34w 8760 1 CF 18w 8760 1 F96T12 HO 8760 1 F48T12 HO 8760 2 F40T12 34w 2600 2 F30T12 25w 2600 1 Inc. 150w 2600 2 F40T12 34w 4200 2 CF 7w 8760 2 F40T12 34w 4200 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 5000 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 3700 2 F40T12 34w 4200 2 CF 7w 8760 2 F40T12 34w"3700 2 F40T12 34w 3700 2 F40T12 34w 3700 Proposed Conditions Retrofit Description 12 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/bait backup when needed 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 21 (2) F32T8 lamp, (1) 2L nl elect bllst 21 (2) F32T8 lamp, (1) 2L nl elect bllst 5 (2) F32T8 lamp, (1) 2L ~l-elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F3218 lamp, (1) 2L nl elect bllst. 4 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/batt backup when needed 4 DND (items left as is) 9 (2) F32T8 lamp, (1) 2L nl elect bllst 16 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/bait backup when needed 1 (2) F32T8 lamp, (1) 2L nl elect bllst 5 DND (items left as is) 2 (1) F96T8 HO lamp, (1) 1L HO elect bllst 1 (1) F32T8 lamp, (1) 1L nl elect bllst 1 (1) F32T8 lamp, (1) 1L nl elect bllst 1 (2) F25T lamps, (1) 2L Ip elect bllst 2 New 9’ can with 2) 15w CF lamps 24.(2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/bait backup when needed 14 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 10 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/balt backup when needed 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page6 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp 264 20-Open Office 9 2’x4’x 2L rec trf pblc 2 265 21-Private Office 2 2’x4’x 2L rec trf pblc 2 266 22-Open Office 2 2’x4’x 2L rec trf pblc 2 267 23~OpenOffice 2 CF1Lcnfxt ¯ 1 268 24-OpenOffice 17 2’x4’x2Lrectrfpblc 2 269.25-Private Office 2 2’x4’x 2L rec trf pblc 2 270 SWA-Stain~ell Alcove 1 CF 2L exit sign ss 2 271 SWA-Stairwell Alcove 1 l’x4’x 2L sm strip 2 Lamp Type F40T12 34w F40T12 34w F40T12 34w CF 18w F40T12 34w F40T12 34w CF7w F40T12 34w 154 1-ElevatorLobby 5 CF1Lcnfxt 1 CF18w 155 1-Elevator Lobby 1 l’x4’x 1L rec strip 1 F48T12 HO 165 1-Elevator Lobby 2 l’x8’x 1L rec stdp 1 F96T12 HO 179 3-Women’s 1 l’x4’x2Lwmwp 2 F40T1234w 180 3-Women’s 1 l’x3’x2Lwmwp 2 F30T1225w 181 3-Women’s 2 Inc. 1L rec can 1 Inc. 150w 272 4-Hallway 3 CF1Lcnfxt 1 CF18w 273 4-Hallway 1 CF 2L exit sign ss 2 CF 7w 274 4-Hallway 2 2’x4’x 2L rectrf 2 F40T12 34w 275 5-Open Office 6 2’x4’x 2L rec trf 2 F40T12 34w 276 5-OpenOffice 1 CF1Lcnfxt 1 CF18w 277 6-File Room 1 2’x4’x 2L rec trf 2 F40T12 34w 278 7-Private Office 3 2’x4’x 2L rectrf 2 F40T12 34w 279 8-Private Office 3 2’x4’x 2L rec trf 2 F40T12 34w 280 9-Private Office 2 2’x4’x 2L rec trf 2 F40T12 34w 281 10-Library 3 2’x4’x 2L rectrf 2 F40T12 34w 282 10-Library 3 CF1Lcnfxt 1 CF18w 283 11-Hallway 3 CF1Lcnfxt ¯ i CF18w 284 12-Conference 3 2’x4’x 2L rectrf 2 F40T12 34w 285 13-PdvateOffice 3 Inc. 1Lmccan 1 Inc. 50w 286 13-Private Office 3 2’x4’x 2L rec trf 2 F40T12 34w 287 14-Open Office 2 2’x4’x 2L mctrf 2 F40T12 34w 288 . 14-OpenOffice 1 CF1Lcnfxt 1 CF18w 289 15-Private Office 2 2’x4’x 2L rec trf 2 F40T12 34w 290 16-Private Office 5 2’x4’x 2L rectrf 2 F40T12 34w 291 17-Private Office 2 2’x4’x 2L mctrf 2 F40T12 34w 292 18-Private Office 3 2’x4’x 2L rectrf 2 F40T12 34w 293 19-Private Office 2 2’x4’x 2L mctff 2 F40T12 34w 294 20-OpenOfflce 6 CF1Lcnfxt 1 CF18w 295 20-OpenOffice 15 2’x4’x2Lrectrf 2 F40T1234w 296 21-CopyRoom 1 CF1Lcnfxt 1 CF18w 297 21-Copy Room 2 2’x4’x 2L mc trf 2 F40T12 34w 298 22-OpenOffice 5 CF1Lcnfxt 1 CF18w 299 22-Open Office 8 2’x4’x 2L mc tff pblc 2 F40T12 34w 300 23-Private Office 2 2’x4’x 2L mc trf pblc 2 F40T12 34w Hours 4200 3700 4200 4200 4200 3700 8760 8760 8760 8760 8760 2600 2600 2600 5000 8760 5000 4200 4200 3700 3700 3700 3700 3700 3700 5000 3700 3700 3700 4200 4200 3700 4200 3700 3700 3700 4200 4200 3700 3700¯4200 4200 3700 Proposed Conditions City Retrofit Description 9 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 DND (items left as is) 17 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 LED exit sign w/batt ball,up when needed 1 (2) F32T8 lamp, (1) 2L nl elect bllst 5 DND (items left as is) 1 (1) F32T8 lamp, (1) 1L nl’elect bllst 2 (1) F96T8 HO lamp, (1) 1L HO electbllst 1 (1) F32T8 lamp, (1) 1L nl elect bllst 1 (2) F25T lamps, (1) 2L Ip elect bllst 2 New 9’ can with 2) 15w CF lamps 3 DND (items left as is) 1 LED exit sign w/bait backup when needed 2 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (1) 2L nl ~lect bllst 1 DND (items left as is) 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1).2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3 DND (items left as is) 3 DND (items left as is) 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (1) CF 15w lamps and ballast, reflective housing 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 DND (items left as is) 2 (2) F32T8 lamp, (1) 2L nl elect bllst 5 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst . 6 DND (items left as is) 15 (2) F32T8 lamp, (1) 2L nl elect bllst 1 DND (items left as is) 2 (2) F32T8 lamp, (1) 2L nl elect bllst 5 DND (items left as is) 8 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page7 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Lamp Type 301 23-PrivateOffice 1 CF1Lcnfxt 1 CF18w 302 24-Private Office 3 CF 1L (~n fxt 1 CF 18w 303 24-Private Office 2 2’x4’x 2L rec Irf pblc 2 F40T12 34w 304 25-Private Office 2 2’x4’x 2L rec trf pblc 2 F40T12 34w 305 26-Private Office 7 2’x4’x 2L rec trf pblc 2 F40T12 34w 306 27-Private Office 3 2’x4’x 2L rec trf pblc 2 F40T12 34w 307 28-Private Office 2 2’x4’x 2L rec trf pblc 2 F40T12 34w 308 " SWA-Stairwell Alcove 1 CF 2L exit sign ss " 2 CF 7w 309 SWA-Stairwell Alcove 1 l’x4’x 2L sm strip 2 F40T12 34w 8 ¯ 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 A 333 334 335 336 337 338 339 34O 341 342 Proposed Conditions Hours Qty Retrofit Description 3700 1 DND (items left as is) 3700 3 DND (items left as is) 3700 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4200 7 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 2 (2) F32T8 lamp, (1) 2L ril ~lect bllst 8760 1 LED exit sign w/batt backup when needed 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1-Elevator Lobby 9 CF 2L cn fxt 2 CF 15w 8760 1-Elevator Lobby 2 LED wm ss grn 1 LED 8760 2-Men’s Restroom 1 CF 2L cn fxt 2 CF 15w 2600 2-Men’s Restroom 1 l’x3’x 2L wm wp 2 F30T12 25w 2600 3-Women’s 1 l’x4’x 1L wm wrap 1 F40T12 34w 2600 3-Women’s 1 CF 2L cn fxl 2 CF 15w 2600 4-Open Office 12 2’x4’x 2L rec trf pblc 2 F32T8 .4200 4-Open Office 1 LED wm ss gm 1 LED ¯ 8760 5-Private Office 2 2’x4’x 2L rectrf pblc 2 F32T8 3700 .6-Open Office 11 2’x4’x 2L rec trf pblc 2 F32T8 4200 7-Open Office 10 2’x4’x 2L rec trf pblc 2 F32T8 4200 7-Open Office 3 LED wm ss gm 1 LED 8760 7-Open Office 3 CF 2L cn fxt 2 CF 15w 4200 8-HVAC Equipment 8 l’x8’x 4L pm hood 4 F96T12 60w . 1100 8-HVACEquipment 2 l’x4’x2Lsmhood 2 F40T1234w 1100 8-HVAC Equipment 1 l’x8’x 2L pm hood 2 F40T12 34w 1100 9-HVAC Equipment 2 Inc. 1L wm jj 1 Inc. 75w 1100 SW2-Stairwell (East)16 l’x4’x 2L wm wp 2 F40T12 34w 8760 SW2-Stairwell (East)~1 CF 1L cn fxt 1 CF 18w 8760 SW2-.StainNell (East)2 Inc. 1L wm jj 1 Inc. 75w 8760 SW2-Stairwell (East)1 CF 2L exit sign ss 2 CF 7w 8760 SWA-StainNell (West)1 LED wm ss gm 1 LED 8760 SWA-StainNell (West)1 Inc. 1L wm jj ’1 Inc. 75w 8760 1-Reproduction 35 2’x4’x 2L rec trf 2 F40T12 34w 2-Repr.oduction 2 2’x4’x 2L rec trf 2 F40T12 34w 3-Reproduction 1 2’x4’x 2L rec trf 2 F40T12 34w 4-Hallway 2 Inc. 1L rec can 1 Inc. 150w 5-Alcove 1 Inc. 1L jj 1 Inc. 250w 6-Men’s Restroom 2 l’x3’x 2L wm wp 2 F30T12 25w 6-Men’s Restroom 2 Inc. 1L rec can .1 Inc. 150w 7-Women’s 2 Inc. 1L rec can 1 Inc. 150w ¯ 7-Women’s 1 l’xS’x 2L sm strip 2 F40T12 34w 7-Women’s 2 l’x3’x 2L wm wp 2 F30T12 25w 9 DND (items left as is) 2 DND (items left as is) 1 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 1 (2) F25T lamps, (1) 2L Ip elect bllst t (1) F32T8 lamp, (1) 1L Ip elect bllst 1 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 12 DND (items left as is) 1 DND (items left as is) 2 DND (items left as is) 11 DND (items left as is) 10 DND (items left as is) 3 DND (items left as is) 3 DND (items left as is) 8 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (1) CF 15w lamps and ballast 16 (2) F32T8 lamp, (1) 2L nl elect bllst 1 DND (items left as is) 2 (1) CF 15w lamps and ballast 1 LED exit sign w/batt backup when needed 1 DND (items left as is) 1 (1) CF 15w lamps and ballast 4200 35 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 2 (2) F32T8 lamp, (1) 2L nl elect bllst 3700 1 (2) F32T8 lamp, (1) 2L nl elect bllst. 5000 2 (2) CF 18w lamp and ballast hardwire 3700 1 DND (items left as is) 2600 2 (2) F25T lamps, (1) 2L Ip elect bllst 2600 2 New 9" can with 2) 15w CF lamps 2600 2 New 9" can with 2) 15w CF lamps 2600 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2600 2 (2) F25T lamps, (1) 2L Ip elect bllst Energy Masters International Page 8 City of Palo Alto PaiD Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description 343 344 345 346 347 348 349 350 351 ’ 352 353 354 355 356 357 358 359 36O 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 8-Hallway 8-Hallway 8-Hallway 9-Lobby 9-Lobby 9-Lobby 10-Office 11-Computer Room 11-Elevator Lobby 11-Elevator Lobby 12-Hallway 12-Hallway 12-Hallway 13-Men’s Restroom 13-Cafeteria - Dinlng 13-Men’s Restroom 13-Cafeteria - Dining 13-Cafeteria - Dining 13-Cafeteria - Dining 13-Cafeteria - Dining 14-Women’s 14-Women’s 14-Engineering 14-Engineenng 15-Engineenng 15-Purchasing 15-Purchasing 16-Engineenng 16-Purchasing 16-Purchasing 17-Engineenng 17-Engineenng 17-Engineenng 18-Engineenng ’ 19-Storage 19-Storage 20-Gymnasium 21-Weight Room 22-Men’s Lockers 23-Battery Room 24-Hallway 25-Women’s Lockers 25-Women’s Lockers 26-Men’s Lockers Lamp 2 l’x8’x 1L rec strip 1 1 l’x4’x 1L rec strip 1 2 Inc. 1L rec can 1 ’ 1 CF 2L exit sign ss 2 11 CF 1L cn fxt 1 7 Inc. 1L rec can 1 2 2’x4’x 4L rectrf 4 7 2’x4’x 2L rec Irf 2 2 l’x8’x 1L rec stdp 1 1 l’x4’x 1L rec stdp 1 4 2’x4’x 2L rectrf 2 3 CF 1Lcn fxt 1 1 CF 2L exit signss 2 1 Inc. 1Lsmsq 1 5 Inc. 1Lreccan 1 1 l’x4’x 2L wm wp 2 5 Inc. 1L can 1 1 l’x4’x 1L sm hood 1 1 l’x2’x 2L smwp 2 22 CF 1Lscrewin D 1 1 l’x4’x 2Lwm wp.2. 1 Inc. lLsmsq 1 24 l’x8’x 2L sm strip 2 6 l’x4’x !L sm strip 1 1 l’x4’x 2L pm wrap 2 2 LEDwmssgm 1 14 2’x4’x 2L rec trf pblc 2 2 l’xS’x 4L pm hood 4 1 LEDwmssgm 1 11 2’x4’x 2L mc trf pblc 2 1 l’x4’x 2L pm wrap 2 1 l’x4’x 2L sm strip 2 14 Inc. 1L sm hood 1 1 2’x4’x 4Lmctrf 4 1 l’x4’x 1L sm strip 1 1 l’x4’x 2L sm stdp 2 6 l’x8’x 4L sm hood 4 12 2’x4’x 2L rec trf 2 7 l’x4’x 2L wm strip 2 3 l’x4’x 2L sm strip 2 1 l’x8’x 2L sm strip 2 1 l’x4’x 1L sm strip 1 4 l’x8’x 2.L sm stdp 2 7 l’x8’x 4L sm hood 4 Lamp Type F96T12 HO F48T12 HO Inc. 150w CF7w CF 22w Inc. 150w F40T12 34w F40T12 34w F96T12 HO F48T12 HO F40T12 34w CF 18w CF 7w Inc. 75w Inc. 150w F40T12 34w Inc. 100w F40T12 34w F20T12 20w CF 18w F40T12 34w Inc. 75w F40T12 34w F40T12 34w F40T12 34w LED F32T8Fg6T12 60w LED F32T8 F40T12 34w F40T12 34w Inc. 150w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Hours 5000 5000 5000. 8760 4200 4200 3700 4200 8760 8760 5000 5000 8760 2600 3500 2600 3500 2600 2600 3500 2600 2600 4200 4200 3700 8760 4200 3700 8760 4200 3700 3700 4200 3700 800 800 3500 3500 3500 2600 5000 2600 2600 3500 2 1 2 1 11 7 2 7 2 1 4 3 1 1 5 1 5 1 .1 22 1 1 24 6 1 2 14 2 1 11 1 1 14 1 1 1 6 12 7 3 1 1 4 7 Proposed Conditions Retrofit Description (1) F96T8 HO lamp, (1) 1L HO elect bllst (1) F32T8 lamp, (1) 1L nl electbllst New 9" can with 2) 15w CF lamps LED exit sign w/batt backup when needed (1) CF 18w lamp and ballast hardwire (2) CF 18w lamp and ballast hardwire (4) F32T8 lamp, (1) 4L Ij)elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (1) F96T8 HO lamp, (1) tL HO elect bllst (1) F32T8 lamp, (1) 1L nl elect bllst (2) F32T8 lamp, (t) 2L nl elect bllst DND (items left as is) LED exit sign w/batt backup when ~eeded New sm dram with (2) CF 15 watt lamps and ballast (2) CF 18w lamp and ballast hardwire (2) F32T8 lamp, (1) 2L nl elect bllst (1) CF 22w lamp and dimming ballast (1) F32T8 lamp, (1) 1L Ip elect bllst (2) F17T8 lamps, (1) 2L Ip elect bllst DND (items left as is) (2) F32T8 lamp, (1) 2L nl elect bllst New sm drum with (2) CF 15 watt lamps and ballast (2) F32T8 lamp, (1) 2L nl elect bllst (1) F32T8 lamp, (1) 1L Ip elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst DND (items left as is) DND (items left as is) (4) F32T8 lamp, (1) 4L Ip elect bllst DND (items left as is) DND (items left as is) (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (1) CF 32w lamp and ballast (4) F32TS.lamp, (1) 4L Ip elect bllst (1) F32T8 lamp, (1) 1L Ip elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (4) F32T8 lamp, (1) 4L Ip elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1)2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (1) F32T8 lamp, (1) 1L Ip elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst (4) F32T8 lamp, (1) 4L Ip elect bllst Energy Masters International Page 9 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Oty Description Lamp 387 27-Men’s Restroom 3 l’x4’x 2L wm wp 2 388 27-Men’s Restroom 3 l’x3’x 2Lwm wp 2 389 27-Men’s Restroom 1 l’x4’x 2L sm wp 2 390 28-Showers 3 l’x4’x 2L sm wp 2 391 29-Control Room 36 2’x4’x 2L rec trf 2 392 30-Hallway 1 l’x8’x 2L sm strip 2 393 30-Hallway 1 l’x4’x 1L sm strip 1 394 30-Hallway 6 2’x4’x 2L rec trf 2 395 31:Hallway 1 CF 2L exit sign ds 2 396 31:Hallway 1 CF 2L exit sign ss 2 397 31-Hallway 6 2’x4’x 2L rec tn’ ¯2 398 32-Private Office 2 2’x4’x 2L rec tn’2 399 33-Private Office 2 2’x4’x 2L rectff 2 400 34-Open Office °4 2’x4’x 2L rec in’2 401 35-Open Office 3 2’x4’x 2L rec trf 2 402 36-Open Office 8 2’x4’x 2L rectn’2 403 37-Open Office 6 2’x4’x 2L rec trf 2 404 38-Private Office 2 2’x4’x 2L rectff 2 405 39-Alcove 2 Inc. 1L rec can 1 406 40,Conference 21 l’x4’x 2L sm wp 2 407 41-Open Office 16 2’x4’x 2L rec Irf 2 408 42-Private Office 2 2’x4’x 2L rec tn’2 409 ¯ 43-Private Office 2 2’x4’x 2L rec In’2 410 44-Private Office 2 2’x4’x 2L rec Iff 2 411 45-Water Heater 2 l’x4’x 1L sm strip 1 412 46-StainNell 1 l’x4’x 2Lsm strip 2 413 47-BreakRoom 2 l’x4’x2Lsmwp 2 414 48-Lounge 2 2’x4’x 2L rec trf 2 415 49-Restroom 1 Inc. 1Lreccan 1 416 49-Restroom 1 Inc. 2Lwm vanity 2 417 50-911Dispatch 13 2’x4’x2Lreclrf 2 418 51-OpenOffice 2 2’x4’x2Lrectrf 2 419 .52-Storage 2 2’x4’x 2L rec trf 2 420 53-Private Office 4 2’x4’x 2L rec trf 2 421 54-Radio Room "3 l’xS’x 4L sm strip 4 422 54-Radio Room 3 l’x4’x 2L sm strip 2 423 55-Phone Room 9 l’x8’x 4L sm hood 4 424 56-Storage 1 l’x4’x 2L sm strip 2 425 57-Generator Room 2 l’x8’x 2L sm strip 2 426 57-Generator Room 2 l’x4’x 1L sm strip 1 427 EXT-Parking 3 MV 1L rec can 1 428 EXT-Parking 1 MH 1Lwmwall pack 1 429 E4-Parking Elevator 6 Inc. 1L rec can 1 430 G-Police Garage 4 l’x8’x 4L sm strip 4 Lamp Type Hours "Qty F40T12 34w 2600 F30T12 25w 2600 F40T12 34w 2600 F40T12 34w 1500 F40T12 34w 4200 F40T12 34w 5000 F40T12 34w 5000 F40T12 34w 5000 CF 7w 8760 CF 7w 8760 F40T12 34w 5000 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 4200 F40T12 34w 4200 F40T12 34w 4200 F40T12 34w 4200 F40T12 34w 3700 Inc. 150w 3700 F40T12 34w 4200 F40T12 34w 4200 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 800 F40T12 34w 8760 F40T12 34w 3700 F40T12 34w 3700 Inc. 150w 2600 Inc. 75w 2600 F40T12 34w 4200 F40T12 34w 4200 F40T12 34w 800 F40T12 34w 3700 F40T12 34w 3700 F40T12 34w 800 F40T12 34w 800 F40T12 34w 800 F40T12 34w 800 F40T12 34w 800 MV 250w 4380 MH 175w ~ 4380 Inc. 50w 8760 F40T12 34w 8760 Proposed Conditions Retrofit Description 3 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F25T lamps, (1) 2L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 36 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (1) F32T8 lamp, (1) 1L I~)-elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect.bllst 1 LED exit sign w/batt backup when needed 1 LED exit sign w/batt backup when needed 6 (2) F32T8 lamp, (1) 2L ql elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 8 (2) F32T8 lamp, (1) 2L nl elect bllst 6 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 New 9" can with 2) 15w CF lamps 21 (2) F32T8 lamp, (1) 2L nl elect bllst 16 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst . 2 (1) F32T8 lamp, (1) 1L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bilst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New 9" can with 2) 15w CF lamps 1 (2) CF 26w lamp and ballast 13 (2)F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L n! elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 9 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (1) F32T8 lamp, (1) 1L Ip elect bllst 3 New 8" can with 2) 32w CF lamps 1 DND (items left as is) 6 DND (items left as is) 4 (4) F32T8 lamp, (1) 4L Ip elect bllst Energy Masters International Page 10 City of Palo Alto Palo Alto City Hall - 250 Hamilton Ave.RETROFIT SCOPE REPORT Existing Conditions Ref # Room # City Description 431 G~Police Garage 20 l’x4’x 1L sm strip 432 G-Police Garage 5 2’x4’x 4L ch wp 433 G-PoliceGarage 13 l’x8’x2Lsmstrip B 434 ELI-Elevator Lobby 3 l’x8’x 2L sm strip C 435 ELI-Elevator Lobby 3 l’x8’x 2L sm strip M 436 1-CompetitiveAssmt.14 2’x4’x2Lrectrfpblc 437 . 1-Competitive Assmt.1 2’x2’x 2L rec trf pblc 438 2-Alcove 1 CF 2L exit sign ss 439 2-Alcove 1 l’x4’x 2L sm strip 440 3-Lobby ._3 CF1Lcnfxt 441 3-Lobby 1 CF 2L exit sign ss 442 4-Human Resources 2 2’x4’x 3L rec trf 443 5-Human Resources 10 2’x4’x 2L rec trf 444 6-Human Resources 4 2’x4’x 3L rec trf ¯ 445 7-Human Resources 1 l’x4’x 2L sm hood 446 8-Human Resources 1 l’x4’x 2L sm hood 447 9-Human Resources 4 2’x4’x 2L rec trf 448 10-Human 3 2’x4’x 3L rec trf 449 11-Elevator Lobby 2 2’x4’x 2L rec trf Parking Structure - A 450 1-Garage - Level A 451 1-Garage- Level A 452 1-Garage- Level A 453 1-Garage- Level A B 454 -Garage- Level B 455 1-Garage- Level B 456 1-Garage- Level B C 457 1-Garage- Level C 458 1-Garage- Level C 459 ’ 1-Garage - Level C 12 l’x4’x 2L sm strip 35 l’x8’x 2L sm strip 4 l’x4’x 1L sm stdp 53 l’x8’x 4L sm strip 12 l’x4’x 1L sm strip 2 CF 2L exit sign ss 225 l’x8’x 2L sm strip 2 CF 2L exit sign ss 218 l’x8’x 2L sm stdp 10 l’x4’x 1L sm strip 2492 ¯ Lamp Lamp Type Hours City 1 F40T12 34w 8760 4 F40T12 34w 8760 2 F40T12 34w 8760 2 F40T1234w 8760 2 F40T12 34w 8760 2 F32T8 4200 2 FB31T8 U3 3700 2 CF7w 8760 2 F40T1234w 3700 1 CF 18w 3700 2 CF7w 8760 3 F40T1234w 3700 2 F40T12 34w 4200 3 F40T12 34w 3700 2 F40T1234w 3700 2 F40T1234w 3700 2 F40T1234w 3700 3 , F40T1234w 3700 2 F40T1234w 8760 2 F40T12 34w 8760 2 F40T12 34w 8760 1 F40T12 34w 8760 4 F40T1234w 8760 1 F40T12 34w 8760 2 CF7w 8760 2 F40T1234w 8760 2 CF7w 8760 2 F40T1234w 8760 1 F40Ti234w 8760 Proposed Conditions Retrofit Description 20 (1) F32T8 lamp, (1) 1L Ip elect bllst 5 (4) F32T8 lamp, (1) 4L Ip elect bllst 13 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (2) F32T8 I~mp, (1) 2L nl elect bllst 3 (2) F32T8 lamp, (1) 2L ~l-elect bllst 14 DND (items left as is) 1 DND (items left as is) 1 LED exit sign w/bait backup when needed 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3 DND (items left as is) 1 LED exit sign w/batt backup when needed 2 (3) F32T8 lamp, (1) 2L & (1) 1L Ip elect bllst 10 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (3) F32T8 lamp, (1) 2L & (1) 1L Ip elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp;(1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 3 (3) F32T8 lamp, (1) 2L & (1) 1L Ip elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 12 (2) F32T8 lamp, (1) 2L nl elect bllst 35 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (1) F32T8 lamp, (1) 1L Ip elect bllst 53 (4) F32T8 lamp, (1) 4L Ip elect bllst 12 (1) F32T8 lamp, (1) 1L Ip elect bllst 2 LED exit sign w/batt backup when needed 225 (2) F32T8 lamp, (1) 2L nl elect bllst 2 218 10 2492 LED exit sign w/batt backup when needed (2) F32T8 lamp, (1) 2L nl elect bilst (1) F32T8 lamp, (1) 1L Ip elect bllst Energy Masters International Page 11 City of Palo Alto Peers Park Club House - 1899 Park Avenue RETROFIT SCOPE REPORT Existing Conditions Ref #- Room # Qty Description Main Building - 1st Floor 1 Office 2 Open Area 3 Closet 4 Men’s Restroom 5 Women’s Restroom 1 l’x4’x 2L PM wp 4 l’x4’x 2L PM wp 0 No Access 1 l’x4’x 2L PM wp 1 l’x4’x 2L PM Wp 7 Lamp 2 2 0 2 2 Lamp Type F40T12 34w F40T12 34w n/a F40T12 34w F40T12 34w Proposed Conditions Hours Qty Retrofit Description 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 4 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 0 DND (items left as is) 8760 1 (2) F32T8 lamp, (1) 2L hi-elect bllst 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 7 Energy Masters International Page 1 City of Palo Alto Rinconada Park RR - 777 Embarcadero Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 1 MRR 1 l’x4’x2Lsmwp 2 WRR 1 l’x4’x2Lsmwp 3 office 1 Inc. 1Ldrum 4 exterior 2 Inc. 1L vandal 5 Lamp 2 2 1 1 Lamp Type F40T12 34w F40T12 34w Inc. 60w Inc. 60w Hour~ 8760 8760 1500 4380 Proposed Conditions Qty RetrofitDescription 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New sm drum with (2) CF 15 watt lamps and ballast 2 (1) CF 15w lamps and ballast 5 Energy Masters International Page 1 City of Palo Alto Rinconada Pool Facility - 777 Embarcadero Road RETROFIT SCOPE REPORT Existing Conditions Ref # Room # City Description Lamp Main Building - 1st Floor 1 Pool Office.2 l’x4’x 2L sm wp 2 2 Men’s Locker 4 l’x4’x 2L sm wp 2 3 Men’s Locker 2 Inc. Jelly Jar 1 4 Office 2 2’x2’2Lsm 2 5 Women’s Locker 4 l’x4’x 2L sm wp 2 6 Women’s Locker 2 Inc. Jelly Jar 1 9 Pool Equipment 2 l’x4’x 2L strip 2 10 Women’s Restroom 1 l’x4’x 2L sm wp 2 11 Men’s Restroom 1 l’x4’x 2L sm wp 2 20 Lamp Type F40T12 34w F40T12 34w Inc. 100w FB40T12 F40T12 34w Inc. 100w F40T12 34w F40T12 34w F40T12 34w Hours Proposed Conditions Retrofit Description 2000 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 2 DND (items left as is) 2000 2 (3) F17T8 lamp, (1) 2L Ip,elect bllst, (1) rfl 2500 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2500 2 DND (items left as is) 800 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (2) F32T8 lamp, (t) 2L nl elect bllst 20 Energy Masters International Page 1 City of PaloAIto Rinconada Pool Snack Bar - 777 Embarcadero Road Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 7 Office Storage 8 Snack Bar 4 l’x4’x 2L sm wp 2 4 l’x4’x 2L sm wp 2 8 Lamp Type F40T1234w F40T1234w Houl~ 80O 800 4 4 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (2) F32T8 lamp, (1) 2L nl elect bllst (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Terman Park Library - 661 Arastradero Rd RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 1 ¯ Entry Hall 2 2’x4’ 3L sm 3 2 Restroom Hall 2 2’x2’ 2L sm prsm 2 3 Men’s Restroom 1 l’x4’x 2L sm wp 2 4 Women’s Restroom 1 l’x4’x 2L sm wp 2 5 Meeting Room 8 1’x4’.4L sm prsm wp 4 6 Main Library 24 1’x4’ 4L sm prsm wp 4 7 Main Library 1 Jelly Jar 1 8 Office 8 1’x4’ 4L sm prsm wp 4 9 Kitchen/Storage 2 l’x4’x 2L sm wp 2 10 Book Area 8 1’x4’ 4L sm prsm wp 4 11 Closet ._1 1’x4 2L sm wp 2 12 Storage 2 Inc. 2L dome 2 13 Mechanical Room 0 NoAccess 0 6O Lamp Type F40T12 34w FB40T12 F40T12 34w F40T12 34w F40T12 34w F40T12 34w ¯ Inc. 60w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc. 60w n/a Proposed Conditions Hours Qty Retrofit Description 1500 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 1500 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 1500 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 1 (2) F32T8 lamp, (1) 2L hi-elect bllst 1500 8 (4) F32T8 lamp, (1) 4L Ip elect bllst 1500 24 (4) F32T8 lamp, (1) 4L Ip elect bllst 1500 1 DND (items left as is) 1500 8 (4) F32T8 lamp, (1) 4L Ip elect bllst 1500 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 8 (4) F32T8 lamp, (1) 4L Ip elect bllst 800 1 (2) F32T8 lamp, (1) 2L nl elect bllst 800 2 New sm drum with (2) CF 15 watt lamps and ballast 800 0 DND (items left as is) 60 Energy Masters International Page 1 City of Palo Alto Terman Park Wing #30 - 661 Arastradero Rd Existing Conditions¯ Ref # Room # ¯ Qty Description Main Building - 1st Floor 1 35 6 l’x8’x4Lsmbox 2 35A 2 2’x8’x 4L sm box 3 RR 2 l’x4’x2Lsmwp 4 34 8 l’x8’x4Lsmbox 5 34 office 2 Inc. 2L-drum 6 33 8 l’x8’x4Lsmbox 7 32 6 l’x8’x4Lsmbox 8 31 8 l’x8’x4Lsmbox 9 RR 2 l’x4’x2Lsmwp Lamp 4 4 2 4 2 4 4 4 2 Lamp Type F96T12 60w F96T12 60w F40T12 34w F96T12 60w Inc.60w F96T12 60w F96T12 60w F96T12 60w F40T1234w Hours 2OO0 2000 2000 2000 2000 2000 2000 2000 2000 6 2 2 8 2 8 6 8 2 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (2) F32T8 lamp, (1) 2L nl elect bllst (8) F32T8 lamp, (2) 4L Ipelect bllst, (1) bracket kit, (1) ballast pan New sm drum with (2) CF 15 watt lamps and ballast (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (2) F32T8 lamp, (1) 2L nl elect bllst Energy Masters International Page 1 City of Palo Alto Ventura Childcare MPR - 3990 Ventura Court RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Main Building - 1st Floor 50 MPR Main Room 15 Inc. 1L PM Hood 51 Stage 3 Inc. 4L drum 52 ¯ Stage 3 Inc. 2L rec exit sign 53 Kitchen ¯3 1’x4’ 4L PM 54 Kitchen 1 2’x4’ 4L PM 55 Exterior 3 Inc. 1L vandal 28 Lamp 1 4 2 4 4 1 Lamp Type Inc. 300w Inc. 60w Inc. 20w F40T12 34w F40T12 34w Inc. 60w Proposed Conditions Hours City Retrofit Description 2000 15 New l’x4’x 2L wrap, w/(2) F32T8 lamps, (1) 2L Ip elect bllst 1200 3 New sm drum with (3) CF 15 watt lamps and ballast 8760 3 LED exit sign w/batt backup when needed 1500 3 (4) F32T8 lamp, (1) 4L Ip elect bllst 1500 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 4380 3 (1) CF 15w lamps and ballast 28 Energy Masters International Page 1 City of Palo Alto Ventura Childcare Unit #1 - 3990 Ventura Court Existing Conditions Ref# Room # Qty ¯ Description Lamp Main Building - 1st Floor 1 Main Office 4 1’x8’ 2L sm prsm 2 2 Main Office Lobby 4 1’x8’ 2L sm prsm 2 3 Main Office Lobby 1 Inc. 1L Square 1 4 Principal Office 1 1’x8’ 2L sm prsm 2 5 Restroom 1 Inc. 1L Globe 1 6 Hall 1 Inc. lLSquare 1 7 Closet 1 Inc. 1L Square 1 8 Pyne Office 2 l’x4’x 2L sm wp 2 9 Break Room 2 l’x4’x 2L sm wp 2 10 Storage 2 Inc. 1L Square 1 11 Kitchen .1 Inc. 1L Square 1 12 Office #1 2 l’x4’x 2L sm wp .2 13 Office #2 2 l’x4’x 2L sm wp 2 14 Office #3 2 l’x4’x 2L sm wp 2 15 Office#4 2 l’x4’x2Lsmwp 2 16 Office #5 2 l’x4°x 2L sm wp 2 17 .Office#5 1 Inc. 1LSquare 1 18 Office #5 Restroom 1 Inc. 1L Square 1 19 Copy Room 3 l’x4’x 2L sm wp 2 35 Lamp Type F96T12 60w F96T12 60w Inc. 100w F96T12 60w Inc. 100w Inc. 100w Inc. 100w F40T12 34w F40T12 34w Inc. 100w Inc. 100w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc. 100w Inc. 100w F40T12 34w Hours 2000 2200 2200 2000 2000 2200 80O 2000 2000 80O 2000 2000 2000 2000 2000 2000 2000 800 1500 4 4 1 1 1 1 1 2 2 2 1 2 2 2 2 2 1 1 3 35 RETROFIT SCOPE REPORT Proposed Conditions Retrofit Description (4)F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (4)F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (1)CF 22w lamp and ballast (4)F32T8 lamp, (1) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan (1)CF 22w lamp and ballast (1)CF 22w lamp and ballast (1)CF 22w lamp and ballast (2)F32T8 lamp, (1).2L nl elect bllst (2)F32T8 lamp, (1) 2L nl elect bllst (1)CF 22w lamp and ballast (1)CF 22w lamp and ballast (2)F32T8 lamp, (1) 2L nl elect bllst (2)F32T8 lamp, (1) 2L nl elect bllst (2)F32T8 lamp, (1) 2L nl elect bllst (2)F32T8 lamp, (1) 2L nl elect bllst (2)F32T8 lamp, (1) 2L nl elect bllst (1)CF 22w lamp and ballast (1)CF 22w lamp and ballast (2)F32T8 lamp, (1) 2L nl elect bllst we ws ws ws Energy Masters Intemational Page 1 City of Palo Alto Ventura Childcare Unit #2 - 3990 Ventura Court RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp Main Building - 1st Floor 32 Classroom8 10 l’x4’4Lsmwp 4 33 Men’s Restroom 2 l’x4’x 2L sm wp 2 34 Mechanical Closet 1 Inc. 1L 1 35 Women’s Restroom 1 l’x4’x 2L sm wp 2 36 Classroom7 10 l’x4’4Lsmwp 4 37 Classroom 7a 1 Inc. 1L 1 38 Infant Room 5 10 l’x4’4Lsmwp 4 39 Infant Room 3 10 l’x4’4Lsmwp 4 40 Infant Room 2 10 1’x4’ 4L sm wp 4 41 Infant Room 1 10 1’x4’ 4L sm wp 4 42 Sleep Room .5 1’x4’ 4L sm wp 4 43 Hall 2 l’x4’x 2L sm wp 2 44 Hall 1 Inc. lL 1 45 Hall 1.1’x4’ 4L sm wp 4 46 Kitchen 2 1’x4’ 4L sm wp 4 47 Infant Room 6 9 1’x4’ 4L sm wp 4 48 Kitchen1 1 Inc. lL 1 49 Kitchen2 1 Inc. lL 1 87 Lamp Type F40T12 34w F40T12 34w Inc. 100w F40T12 34w F40T12 34w Inc. 100w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w Inc. 100w F40T12 34w F40T12 34w F40T12 34w Inc. 100w Inc. 100w Proposed Conditions Hours City Retrofit De$cdption 2000 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 1200 2 (2) F32T8 lamp, (1) 2L nl elect bllst 800 1 (1) CF 22w lamp and ballast 1200 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 1 (1) CF 22w.lamp and ballast 2000 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 5.(4) F32T8 lamp, (1) 4L Ip elect bllst 2000 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 1 (1) CF 22w lamp and ballast 2000 1 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 9 (4) F32T8 lamp, (1) 4L Ip elect bllst 2000 1 (1) CF 22w lamp and ballast 2000 1 (1) CF 22w lamp and ballast 87 Energy Masters International Page 1 City of Palo Alto Ventura Childcare Unit #3 - 3990 Ventura Court Existing Conditions Ref # ¯ ¯ Room # Qty Description Lamp Main Building - 1 st Floor 20 Room #9 5 1’x4’ 4L sm prsm wp 4 21 Storage 1 Inc. 1L Square 1 22 Room10 10 l’x4’4Lsmprsmwp 4 23 Room11 10 l’x4’4Lsmprsmwp 4 24 Room 9 10 1’x4’ 4L sm prsm wp 4 25 Room12 10 l’x4’4Lsmprsmwp 4 26 Roomlla 1 Inc. lLSquare 1 27 Room 12 Restroom 1 l’x4’x 2L sm wp 2 28 Room 12 Office 1 Inc. 2L dome 2 29 Room 13 6 1’x4’ 4L sm wp 4 30 Room 14 6 1’x4’ 4L sm wp 4 31 Room 14 Restroom 1 l’x4’x 2Lwp 2 62 Lamp Type F40T12 34w Inc. 100w F40T12 34w F40T12 34w. F40T12 34w F40T12 34w Inc. 100w F40T12 34w Inc. 60w F40T12 34w F40T12 34w F40T12 34w Hour~ 2000 80O 2000 2000 2000 2000 2000 1200 2000 2000 2000 1200 . RETROFIT SCOPE REPORT Proposed Conditions Qty Retrofit Description 5. (4) F32T8 lampl (1) 4L Ip elect bllst 1 (1) CF 22w lamp and ballast 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 10 (4) F32T8 lamp, (1) 4L Ipelect bllst 10 (4) F32T8 lamp, (1) 4L Ip elect bllst. 10 (4) F32T8 lamp, (1) 4L Ip elect bllst 1 - (1) CF 22w lamp and ballast 1 (2) F32T8 lamp, (1) 2L nl elect bllst 1 New sm drum with (2) CF 15 wa~t lamps and ballast 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 6 (4) F32T8 lamp, (1) 4L Ip elect bllst. 1 (2) F32T8 lamp, (1) 2L nl elect bllst 62 Energy Masters International Page 1 City of Palo Alto WQCP- 2501 Embarcadero Rd Existing Conditions Ref # Room # Qty Description Aerator Tanks - 1st Floor 98 equipment room 3 l’x4’x 2L sm wp Air Compressor - 1st Floor 28 Air Compressor 6.l’x4’x2Lchnpm 29 Air Compressor 12 l’x4’x2Lsmhood Chlorine Building - 1st Floor 102 Chlorine Building 8 l’x4’x2Lsm " 103 Tank Water 10 l’x4’x 2L sm !04. Tank Robm #2 .8 l’x4’x 2L sm 105 PumpRoom 11 l’x4’x2Lsm Electrical Shed - All Floors 32 Electrical Shed 2 l’x4’x 2L chn pm Filter Building,- 2nd Floor 99 Filter Building 2nd 2 2’x2’ 2L sm wp 100 Filter Building 2nd 40 l’x4’x2Lsm, 3rd Floor 101 Filter Building 3rd 6 2’x2’2Lsmwp First Aid Station - 1st Floor 42 First Aid Station 4 1’x8’ 4L chn pm Grit Dumping Bldg - 1st Floor 67 Grit Dumping 6 1’x4’ 4L PM wp Main Building - 1st Floor 1 Plant Manager’s 6 ~ 2’x4’x 2L sm box 2 Entrance Area 8 2’x4’x 2L sm box 3 Entrance Area 1 2’x2’ 2L sm box 4 P. Bobel Office 2 2’x4’x 2L sm box 5 Men’s Restroom 1 1’x3’ 2L WM 6 Men’s Restroom 1 l’x4’x 2L sm wp 7 Copy 1 l’x4’x2Lsmwp 8 File Room 4 2’x4’ 3L rec prsm 9 Women’s Restroom 1 1’x3’ 2L WM 10 Women’s Restroom 1 l’x4’x 2L sm wp 11 Back Hall 3 2’x4’x 2L sm box Lamp 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 Lamp Type F40T12 34w F40T1234w F48T12 HO F48T12 HO F48T12 HO F48T12 HO F48T12 HO F40T12 34w FB40T12 F48T12 HO FB40T12 F96T1260w F40T1234w F40T1234w F40T1234w FB40T12 F40T12 34w F25T8 F40T1234w F40T12 34w F40T12 34w F25T8 ;40T12 34w F32T8 RETROFIT SCOPE REPORT Proposed Conditions Hours Qty Retrofit Description 2000 3 (2) F32T8 lamp, (1) 2L nl elect bllst 1500 6 (2) F32T8 lamp, (1) 2L ~1 ~lect bllst 5000 12 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 5000 8 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3E Ip elect bllst, (1) 5000 10 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (t) 5000 8 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 5000 11 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 5000 2 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 8760 40 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 8760 6 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 3500 4 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1) ballast pan WS 8760 6 (4) F32T8 lamp, (1) 4L Ip elect bllst 3120 6-(2) F32T8 lamp, (1) 2L nl elect bllst W500 8760 ¯8 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 3120 2 (2) F32T8 lamp, (1) 2L nl elect bllst ws 2000 1 DND (items left as is) 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3120 4 (3) F32T8 lamp, (1) 2L Ip elect bllst W500 2000 1 DND (items left as is) 2000 1 (2) F32T8 lamp, (1) 2L nl elect bllst 3500 3 DND (items left as is) ’ Energy Masters International Page 1 City of Palo Alto WQCP - 2501 Embarcadero Rd RETROFIT SCOPE REPORT Existing Conditions Ref # Room # Qty Description Lamp 12 Back Hall 4 2’x2’ 2L sm box 2 13 Javad Ghaffari Office 2 2’x4’ 3L rec prsm 3 14 Conference Room 8 2’x2’ 2L sm box 2 15 Small Bullpen 5 2’x4’ 3L rec prsm 3 16 Small Bullpen 2 Inc. 2L exit sign 2 17 Back Bullpen 15 2’x4’ 3L rec prsm 3 18 Back Bullpen 1 Inc. 2L exit sign 2 19 Back Office 2 2’x4’ 3L rec prsm 3 20 Stairwell 4 l’x4’x 2L sm wp 2 26 Lab 1st Floor 6 2’x4’x 2L sm box 2 Basement 21 Basement 12 l’x4’x 2L chn pm 22 Exercise Room 3 l’x4’x 2L chn pm 23 Storage Basement 8 l’x4’x 2L chn pm 24 Lab Basement 4 l’x4’x 2L chn pm 25 Storage Basement 4 l’x4’x 2L chn pm Main Pump - All Floors 30 Pump 1 l’x4’x 2L chn pm 2 31 MainPump 13 l’x4’x2Lsmhood 2 33 Maintanence Pump 11 l’x4’x 2L sm hood ~ 2 34 Maintanence Pump 12 l’x4’x 2L sm hood 2 35 Explosion Room 10 HPS 1 36 - Motor Room Exhaust 2 l’x4’x 2L sm hood 2 37 PumpRoom Office 4 l’x4’x 2L sm hood 2 38 Pump Room Office 2 2’x2’ 2L rec prsm 2 Old Pump Room - All Floors 39 . Old Pump Room 5 HPS 1 40 Old Pump Room 1 Inc. 1L sm 1 Operations Building - 1st Floor 81 Entry Lobby 24 CF 1L fxt 82 Break Room 30 2’x2’ 2L rec prsm 83 Telephone Room 14 2’x2’ 2L rec prsm 84 Men’sRestroom 18 2’x2’2Lrecprsm 85 Men’s Restroom 4 CF 1L fxt 86 Micro Bio Room 8 2’x2’ 2L rec prsm 87 Equipment Room 1 l’x4’x 2L chn pm 2rid Floor 88 Equipment Room 4 CF 1L fxt 1 89 2nd Hall 14 2’x2’ 2L rec prsm 2 90 2ndHall 10 CF1Lfxt 1 Lamp Type Hours City FB31TS. 3500 F32T8 3120 FB31T8 2000 F32T8 3500 Inc. 20w 8760 F32T8 3500 Inc.20w 8760 F32T8 3120 F40T12 34w 8760 F32T8 3120 2 F40T12 34w 2000 2 F40T1234w 2000 2 F32T8 2000 2 F40T1234w 2000 2 F32T8 2000 F40T1234w 5000 F48T12 HO 5000 F48T12 HO 5000 F48T12 HO 5000 HPS 5000 F48T12 HO 5000 F48T12 HO 5000 FB40T12 5000 HPS 5000 Inc. i00w 5000 1 CF 15w 8760 2 FB40T12 3500 2 FB40T12 800 2 FB40T12 3500 1 CF 15w 3500 2 FB40T12 4000 2 F40T1234w 3120 CF 15w 800 FB40T12 8760. CF 15w 8760 Proposed Conditions Retrofit DescdpUon 4 DND (items left as is) 2 DND (items left as is)ws 8 DND (items left as is) 5 DND (items left as is) 2 LED exit sign w/bait backup when needed 15 DND (items left as is) 1 LED exit sign w/batt ba~:l~up when needed 2 DND (items left as is) 4 (2) F32T8 lamp, (1) 2L nl elect bllst 6 DND (items left as is)W500 12 (2) F32T8 lamp, (1) 2L nl elect bllst w500 3 (2) F32T8 lamp, (1) 2L nl elect bllst WS 8 DND (items left as is)W500 4 (2) F32T8 lamp, (1) 2L nl elect bllst WS 4 DND (items left as is)W500 1 (2) F32T8 lamp, (1) 2L nl elect bll~t 13 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 11 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 12 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 10 DND (items left as is) 2 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 4 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 2 (3) F17T8 lamp, (1) 2L tp elect bllst, (1) rfl 5 DND (items left as is) 1 (1) CF 22w lamp and ballast 24 DND (items leftas is) 30 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 14 (3) F17T8 lamp, (1) 2L lp elect bllst, (1) rfl 18 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 4 DND (items left as is) 8 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 1 (2) F32T8 lampl (1) 2L nl elect bllst 4 DND (items left as is) 14 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 10 DND (items left as is) W2000 WS00 WS Energy Masters International Page 2 City of Palo Alto WQCP - 2501 Embarcadero Rd RETROFIT SCOPE REPORT Ref #Room # Existing Conditions City Description 9t Conml Room 92 Women’s Restmom 93 Lab 94 Lab 95 Lab 96 Lab Office 97 Lab Office Paint Storage - 1st Floor 27 Paint Storage Primary Tanks Bldg - 1st Floor 68 equipment room 69 equipment room 70 equipment room 71 Control Room 72 Hall 73 Supply Room 74 Pump Room #2 75 Pump Room #3 76 Closet 79 Hall 80 Storage Sink Basement 77 pipe tunnelto OPS 78 pipe tunnel to main Sludge Bldg - 1st Floor 59 Slug Center 60 Slug Center Main. 61 Control 62 . Restroom .63 Stairwell 64 Stairwell 2rid Floor 65 2nd Balcony Basement 66 pipe tunnel to pdm Tool Shed - 1st Floor 41 Tool Shed Warehouse - 44 2’x2’ 2L rec prsm 3 2’x2’ 2L rec prsm 2 1’x4’ 4L PM wp 70 2’x2’ 2L rec prsm 4 1’x4’ 4L CM wp 6 2’x2’ 2L rec prsm 4 2’x2’ 2L rec prsm 9 l’x4’x 2L sm hood 6 3 8 1 1 2 0 No Access 39 l’x4’x 2L chn pm 2 Inc..3L dome 2 2’x2’ 2L rec prsm 2 l’x4’x 2L chn pm 3 l’x4’x2Lchn pm 21 l’x4’x 2L chn pm 28 l’x4’x 2L chn pm 2 l’x4’x 2L chn pm 2 l’x4’x 2L chn pm 1 l’x4’x2Lchn pm 9 l’x4’x 2L chn pm 16 l’x4’x 2L sm l’x4’x 2L chn pm l’x4’x 2L chn pm l’x4’x 2L chn pm Inc. 1L Inc. 1L Inc. 1L l’x4;x 2L chn pm 13. l°x4’x 2L chn pm 1 l’x4’x 2L sm hood Lamp 2 2 4 2 4 2 2 0 2 3 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 Lamp Type FB40T12 FB40T12 F40T12 34w FB40T12 F40T12 34w FB40T12 FB40T12 F48T12 HO n/a F40T12 34w Inc. 60w FB40T12 F40T12 34w F40T12 34w F48T12 HO F48T12 HO F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T1234w F40T12 34w Inc. 100w Inc. 100w Inc. 100w F48T12 HO F40T12 34w F48T12 HO Proposed Conditions Hours Qty Retrofit Description 8760 44 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 3500 3 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 8760 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 8760 70 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 8760 4 (4) F32T8 lamp, (1) 4L Ip elect bllst 3120 6 (3) F17T8 lamp, (1) 2L Ip_elect bllst, (1) rfl 3120 4 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl w500 ws 1500 9 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 8760 0 DND (items left as is) 8760 39 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 2 New sm drum with (3) CF 15 watt lamps and ballast 8760 2 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 8760 .2 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 3 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 21 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 8760 28 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) 2500 2 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 2 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 1 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 9 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 16 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 6 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 3 (2) F32T8 lamp, (1) 2L nl elect bllst 8760 8 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 1 (1) CF 22w lamp and ballast 8760 1 (1) CF 22w lamp and ballast 8760 2 (1) CF 22w lamp and ballast W500 8760 3 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (l) 3L Ip elect bllst, (1) 8760 13 (2) F32T8 lamp, (1) 2L nl elect bllst 5000 1 New l’x4’x 3L ind hood, w/(3) F32T8 lamps, (1) 3L Ip elect bllst, (1) Energy Masters International Page 3 City of Palo Alto WQCP - 2501 Embarcadero Rd RETROFIT SCOPE REPORT Existing Conditions Ref # Room # City Description 1st Floor 52 Rick Shop.28 1’x4’ 4L chn pm 53 Maintenance Shop 24 1’x4’ 4L chn pm 54 ~ Stores 28 1’x4’ 4L 55 Stores 3 1’x4’ 4L chn pm 56 stores 27 l’x4’x 2L ct~n pm 57 Stores Office 3 2’x4’ 4L rec prsm 58 Tool Room 3 2’x4’ 4L rec prsm Warehouse Office - 1st Floor 43 Warehouse Office 7 2’x2’ 2L rec prsm 44 Warehouse Office 11 2’x4’ 4L rec prsm 45 Men’s Restroom -3 l’x4’x 2L sm rec 46 Men’s Restreom 4 2’x2’ 2L rec prsm 47 Women’s Restroom 1 Inc. 1L rec Square 48 Women’s Restroom 3 2’x2’ 2L rec prsm 49 Lunch Room 4 2’x4’ 4L rec prsm 50 Janitor Closet 1 Inc. 1L sm 51 Warehouse 11 2’x4’ 4L rec prsm 883 Lamp 4 4 4 4 2 4 4 2 4 2 2 1 2 4 1 4 Lamp Type F48T12 HO F48T12 HO F40T12 34w F48T12 HO F48T12 HO F40T12 34w F40T12 34w FB40T12 F40T12 34w F40T12 34w F20T12 20w Inc, 60w F20T12 20w F40T12 34w Inc. 100w F40T12 34w Proposed Conditions Hours Qty Retrofit Descdption 3120 28 New l’x4’x 4L ind hood, w/(4) F32T8 lamps, (1) 4L Ip elect bllst, (1) W20 3120 24 New l’x4’x 4L ind hood, w/(4) F32T8 lamps, (1) 4L Ip elect bllst, (1) W20 3500 28 (4) F32T8 lamp, (1) 4L Ip elect bllst 3500 3 New l’x4’x 4L ind hood, w/(4) F32T8 lamps, (1) 4L Ip elect bllst, (1) 3500 27 (2) F32T8 lamp, (.5) 4L.nl. elect bllst 3500 3 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 3 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 3120 7 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl 3120 11 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2000 3 (2) F32T8 lamp, (1) 2L nl elect bllst 2000 4 (2) F17T8 lamps, (1) 2L Ip elect bllst 2000 1 (1) CF 22w lamp and ballast 2000 3 (2) F17T8 lamps, (1) 2L Ip elect bllst 2000 4 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 800 1 (1) CF 22w lamp and ballast 3120 11 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 883 W500 W500 Energy Masters International Page4 City of Palo Alto Cubberley Community - 4000 Middlefield Road Existing Conditions Ref # Room # Qty Description Lamp Building T - Ist Floor 3 Del Thorpe 2 2’x4’ 4L sm wp 4 Kathy Espinosa 2 2’x4’ 4L sm wp 10 C1 Maggie’s Office 2 2’x4’ 4L sm wp 16 Office 2 2’x4° 4L sm wp 19 Office 2 2’x4’ 4L sm wp 10 4 4 4 4 4 Lamp Type F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w SENSOR LOCATION REPORT Proposed Conditions Qty Retrofit Description Sensor Senso r 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst 2 (4) F32T8 lamp, (1) 4L Ip elect bllst t0 WS 1 ws 1 ws 1 ws 1 ws 1 Energy Masters International Lighting Sensor Page 1 City of Palo Alto Municipal Services Center Bldg A - 3201 E. Bayshore Road Existing Conditions Ref # Room # Qty Description Lamp Lamp Type Building A - 1st Floor 9 parks and golf office 12 office #2 13 office#3 17 office #4 18 office#5 4 l’x4’x 2L sm wp 1 l’x4’x 2L sm wp 2-2’x4’x 4L sm box 2 l’x4°x 2L sm wp 2 l°x4’x 2L sm wp 11 2 2 4 2 2 F40T12 34w F40T12 34w F40T12 34w F40T12 34w F40T12 34w SENSOR LOCATION REPORT Proposed Conditions Qty Retrofit Description Sensor Senso r 4 (2) F32T8 lamp, (.5) 4L nl elect bllst 1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect b!lst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 11 w500 1 ws 1 ws 1 ws 1 ws 1 5 Energy Masters International Lighting Sensor Page 1 City of Palo Alto Municipal Services Center Bldg B - 3201 E. Bayshore Road SENSOR LOCATION REPORT Existing Conditions Ref # Room # Qty Description Lamp Lamp Type Building B - 1st Floor 47 Office #2 2 2’x4’ 4L 4 F40T12 34w 49 Break Room 1 2’x4’ 4L 4 F40T12 34w 50 Storage 2 2’x4’ 4L 4 F40T12 34w 54 Office 2 l’x4’x 2L sm wp 2 F40T12 34w 59 Upstairs Plan Room 1 4’x’4 4L 4 F40T12 34w 61 Men’s Locker Room 3 l’x4’x 2L sm wp 2 F40T12 34w 62 Men’s Restroom 4 l’x4’x 2L sm wp 2 F40T12 34w 64 Rehab Office #1 2 l’x4’x 2L sm wp 2 F32TS. 65 Rehab Office #2 4 l’x4’x 2L sm wp 2 F40T12 34w 66 Rehab Office #3 4 l’x4’x 2L sm wp 2 F40T12 34w 69 Equipment Manger’s .2 l’x4’x 2L sm wp 2 F40T12 34w 27 Proposed Conditions Retrofit Descdption Sensor Senso r 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl 2 (2) F32T8 lamp, (1) 2L nl elect bllst 1 (4) F32T8 lamp, (1) 4L Ip elect bltst 3 (2) F32T8 lamp, (1) 2L nl elect bllst 4 (2) F32T8 lamp, (1) 2L nl elect bllst 2 DND (items left as is) 4 (2) F32T8 lamp, (1) 2L nl elect bllst ~1 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect.bllst 27 ws 1 ws,1 ws 1 ws 1 ws 1 W500 W500 1 ws 1 ws 1 ws 1 ws 1 Energy Masters International Lighting Sensor Page 1 City of Palo Alto Municipal Services Center BldgC - 3201 E. Bayshore Road Existing Conditions Ref# Room # Qty Description- Lamp Lamp Type Building C - 1st Floor 88 undergound 125 water & gas ops 126 ¯ water & gas ops 128 water & gas ops 129 water & gas ops 8 l’x4’x 2L sm hood 2 F40T12 34w 2 2’x4’x 3L rec trf pblc 3 F40T12 34w 2 2’x4’x 3L rec trf pblc 3 F40T12 34w 2 2’x4’x 3L rec trf pblc 3 F40T12 34w 6 2’x4’x 3L rec trf pblc 3 F40T12 34w 20 SENSOR LOCATION REPORT Proposed Conditions ¯ Retrofit Description Sensor Senso r 8 (2) F32T8 lamp, (.5) 4L nl elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bltst 6 (3) F32T8 lamp, (1) 2L Ip elect bllst 20 W500 1 ws 1 ws 1 ws 1 w500 1 5 Energy Masters International Lighting Sensor Page 1 City of Palo Alto Municipal Services Center Scada Bldg - 3241 E. Bayshore Road SENSOR LOCATION REPORT Existing Conditions Ref# Room# Qty Description Lamp Lamp Type Qty Main Building - 1st Floor 6 Office #5 7 Office #4 11 Office #8 12 Office #9 2 2’x4’ 3L rec prsm 3 2 2’x4’ 3L rec prsm 3 2 2’x4’ 3L rec prsm 3 2 2’x4’ 3L rec prsm 3 8 F40T12 34w F40T12 34w F40T12 34w F40T12 34w- Proposed Conditions Retrofit Description Sensor Senso r 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bllst 2 (3) F32T8 lamp, (1) 2L Ip elect bltst 8 ws 1 ws 1 ws 1 ws 1 4 Energy Masters International Lighting Sensor Page 1 City of Palo Alto Ventura Childcare Unit #1 - 3990 Ventura Court SENSOR LOCATION REPORT Ref# Room# Main Building - 1st Floor 8 Pyne Office 13 Office #2 14 Office #3 15 Office #4 Existing Conditions Qty Description Lamp_Q~y 2 l’x4’x 2L sm wp 2 2 l’x4’x 2L sm wp 2 2 l’x4’x 2L sm wp 2 2 l’x4’x 2L sm wp 2 8 Lamp Type F40T1234w F40T1234w F40T1234w F40T1234w Proposed Conditions Qty Retrofit Description Sensor Senso r 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 2 (2) F32T8 lamp, (1) 2L nl elect bllst 8 ws 1 ws ws 1 ws 1 4 Energy Masters International Lighting Sensor Page 1 City of Palo Alto WQCP - 2501 Embarcadero Rd Existing Conditions Ref # Room # Qty Description First Aid Station - 1st Floor 42 First Aid Station 4 1’x8’ 4L chn pm Main Building - 1st Floor 1 Plant Manager’s 6 2’x4’x 2L sm box 4 P. Bobel Office 2 2’x4’x 2L sm box 8 File Room 4 2’x4’ 3L rec prsm 13 Javad Ghaffad Office 2 2’x4’ 3L rec prsm 26 Lab 1st Floor 6 2’x4’x 2L sm box Basement 21 Basement 12 l’x4’x2Lchnpm 22 Exercise Room ~l’x4’x 2L chn pm 23 Storage Basement 8 l’x4’x 2Lchn pm 24 Lab Basement 4 l’x4’x 2L chn pm 25 Storage Basement 4 l’x4’x 2L chn pm Operations Building - 1st Floor 82 Break Room 30 2’x2’ 2L rec prsm 84 . Men’s Restmom 18 2’x2’ 2L rec prsm 86 Micro Bio Room 8 2’x2’ 2L rec prsm 2rid Floor 96 Lab Office 6 2’x2’ 2L rec prsm 97 Lab Office 4 2’x2’ 2L rec prsm Sludge Bldg - 1st Floor 59 Slug Center 6 l’x4’x 2L chn pm Warehouse - 1st Floor 52 Rick Shop 28 1’x4’ 4L chn pm 53 Maintenance Shop 24 1’x4’ 4L chn pm Warehouse Office - 1st Floor ¯ 49 Lunch Room 4 2’x4’ 4L rec prsm 51 Warehouse 11 2’x4’ 4L rec prsm 194 Lamp 2 2 3 3 2 2 2 2 2 2 2 2 2 2 2 4 4 Lamp Type F96T12 60w F40T1234w F40T1234W F40T1234w F32T8 F32T8 F40T1234w F40T1234w F32T8 F40T1234w F32T8 FB40T12 FB40T12 FB40T12 FB40T12 FB40T12 F40~12 34w F48T12 HO F48T12 HO F40T12 34w 4 F40T1234w 11 194 SENSOR LOCATION REPORT Proposed Conditions Qty Retrofit Description Sensor Senso r 4 (8) F32T8 lamp, (2) 4L Ip elect bllst, (1) bracket kit, (1)WS 1 6 (2) F32T8 lamp, (1) 2L nl elect blist W500 2 (2) F32T8 lamp, (1) 2L nl elect bllst ws 4 (3) F32"r8 lamp, (1) 2L Ip elect bllst W500 . 2 DND (items left as is)ws 6 DND (items left as is). W500 12 (2) F32T8 lamp, (1) 2L nl elect bllst WS00 3 (2) F32T8 lamp, (1) 2L nl elect bllst wS 8 DND (items left as is)W500 4 (2) F32T8 lamp, (1) 2L nl elect bllst WS 4 DND (items left as is)W500 1 I 1 1 1 1 1 I 1 1 30 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl W2000 18 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl W500 8 (3) F17T8 lamp, (1) 2~_ Ip elect bllst, (1) rfl WS 6 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl W500 4 (3) F17T8 lamp, (1) 2L Ip elect bllst, (1) rfl ws 1 2 1 1 1 6 (2) F32T8 lamp, (1) 2L nlelect bllst W500 1 28 New l’x4’x 4L ind hood, w/(4) F32T8 lamps, (1) 4L Ip 24 New l’x4’x 4L ind hood, w/(4) F32T8 lamps, (1) 4L Ip W2000 W2000 1 1 (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl (2) F32T8 lamp, (1) 2L nl elect bllst, (1) rfl W500 W500 1 1 Energy Masters International Lighting Sensor Page 1 City of Palo Alto ATTACHMENT "B" SCHEDULE & PAYMENT Schedule Construction completion is estimated at 90 days from contract signature with substantial completion within 60 days. Construction schedules will be provided at-the construction kick-off meeting. 2. Price Se~en hundred ten thousand one hundred forty four dollars $710,144 3. Payment Terms - Monthly Progress Payments 90% of project cost due net thirty (30) days after receipt of invoice monthly as work progresses. Energy Masters International will estimate the percent completion on a monthly basis, which will be approved and accepted by the Owner’s representative prior to presentation of invoice for payment. 10% retention due net forty-five (45) days after a "Notice of Completion of Project" has been signed by the Owner. Fast Track Lighting Efficiency Upgrades For Pa!o Alto Municipa! Buildings Presented By EN ERGY MASTERS INTERNATIONAL- 2235 California Street #188 Mountain View, CA 94040 (650) 988-9693 Spring 2001 Executive Summary ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ Monthly Demand Savings = 389.6 kilowatts (kW) Annual Usage Savings = 1,453,917 kilowatt-hours (kWh) Annual Utility Cost Savings -- $109,625 Annual Maintenance Savings -- $7,996 CPAU Rebate --$249,033 Payback After Rebate -- 4.21 years (maint. savings not included) Cost After Rebate -- $461,111 Project cost = $710,144 Methodology and Assumptions ¯Recommendations were developed with demand and energy savings as a priority. ¯Approximately 60 facilities were analyzed for easy-to-implement projects. ¯All facilities were evaluated for lighting opportunities. " ¯Lighting levels will be maintained or improved unless over illuminated. ¯Hours of operation for each space were determined from on-site interviews. ¯Existing electric utility rates were escalated 30% to $0.074. ¯Prevailing wage and overtime included in cost. ¯All lamp and ballast recycling/disposal will be performed according to EPA Green Lights specifications and State of California requirements. ¯All no fee permits are included in the total cost. ¯Every effort will be made to complete construction by June 29th with a May 8th construction start. ¯Supplemental documentation has been provided (electronically) for space-by-space recommendations. 1; I 1 Summary Table Palo Alto Municipal Buildings ’heafre 4 Theabe Scene Shop 4 StaUon # 3 4 1: 7 7 3 Cenbr 4 1 7 4 4 3 1 1 4 1 4 3 1 7 Dark Club Hous~2 1 Electric Demand (kW) Reduction Graph Electric Usage (kWh) Reduction Graph Project Financial Summary Graph Environmental Benefits Lowering energy use also lowers energy production at the source. A great deal of the electricity, which is consumed by the facility, is produced by power plants burning fossil fuels. The burning of these fuels contributes to environmental contamination, which is becoming more and more of an issue. According to the United Stated Environmental Protection Agency, it is estimated that utilities produce the following amount of pollutants for each kilowatt hour of electricity consumed: kWh Saved as by through project implementation 1,453,917 Acid rain Smog Acid rain Pollutant CO2 Ib/kWH NOX g/kWH SO2 g/kWH Coal not burned 2.4 4 - 10 Fuel Oil not burned 2 1.9 5.4 Gas not burned 1.3 21 0 Pollutants Saved Coal not burned 3,489,401 5,815,668 14,539,170 . Fuel Oil not burned 2,907,834 2,762,442 7,851,152 Gas not burned 1,890,092 30,532,257 0 Saving 10,000 kilowatt hours of electricity is equivalent to: Planting 2.9 Acres of Trees Per Year or... Taking 1.4 Cars Off the Road per Year... 422 204 Your New System will: Acres of Trees Planted per Year Cars off the Road per Year Existing Lamp Types Graph Existing Lamp Types Graph O)~.’~"o o o o o o o o o o o o o ~.~o o o o o o o o ~:~ o o o o