HomeMy WebLinkAboutORD 886· .. -.-.\. ,, __ >·.<~~------.. .-.>-·>;;'":_·~----:·:. .-/<~; "' • ·--~·-................ ,, .................... ~~~.---" ·;--··-·--~-·.--. .-. ,,,.,,,.~,,~.~ _,, •· ,, .. .., • ..,,,~,_., • ., .. ,, ... ..-lf,-.•''•'»'t'-"'WI•'•II.....,...,''('~ ¥!"-•••• •'••.!''•" "'"'" ~-~·'"''"'"'""''"'~ .;,", ... ~. v·~~"'"~;-<;1, ~;, ... ;·; [ L .~ - 1 ~.~ '. ; - 0 R D I N A N C E N 0 .. 886 ORDINA.NCE AMEliDING PALO ALTO BUILDING CODE ThE:~ c·ouncil of the City of Palo Alto DO ORDAIN s.s follows: 1. That the last paragraph of Section 3707 of the Palo Alto Bu:ilding Code be a.mend~d to read as follows: The furnace room or rooms shall be located in the basem~nt o:r-cellar or any buildi.n& having a gravity system. The least horizontal dimension o.r such· _turne.ce room shall be s1,; ( 6) feet. The floor or the .furnace room shall be not less than seven (7) teet in the clear belov the bottom of the lowest joists o.f any floor under which lateral heat pipes from the furnace or furnaces are taken and .s:uch :f'loor shall be constructed of 1ncumbust1ble materials,. 2; That the following paragraph be added to Section 3707 ot: the Palo Alto Building Code: Furnaces of' the blower type may be 1nsta.lled 1n a furnace room on any floor of the building under the following requirements: (a.) The furr..ace room shall be in.suleted on walls and ceiling with materials approved for one­ hour fire resistive construction. (b) (c) (d) (e) (f) A clearns.ce of six (6) inches shall be ·required·a.round the sides and rear or the furnace when such furnace is entirely serviceable from the front. A clearance or twelve {12) inches is required from ail'S wood door or six (6) ine-'IJ.es .from a protected wood' door. Furnaces not entirely serviceable f:rom the front shall not be L"'lstalled in a furnace rpomnot.less than si:x (6) feet 1n the least dimension .. The door to furnace rooms shall be o~ sufficient size to per.mi t the removal and replacement of the fu...~ce. When the burner is located w!thin twelve inches of the floor 1 such floor shall be of in­ combustible material. Permanent ventilation in the furnace room cons1sting.of two op~~gs not less than one square foot of free area 1n each shall be P!"OV1ded.. One such opening shall be through the .floor to the sub-floor space or may be located within twelve (12) inches of the floor extending to the exter,ior of' the building 4!)!), :,), ,, '\. .. :: ,:, .!;. .,, -r; :if: ' ~~-~ ~~ :Q_ ., 0 ;.L -------- ORD 886 a tll\Qt&x::: a ; 456 " ' ~ ' ' 0 ' ' ,~ / • • ' , J,' ' " : .(,. • I ' • • • • .1..° ' • ' )" ' ' • > • • \ • ~ .. t:h.rough a. metal du4t. The other opening shall be located v1th.1n twelve (12) inches of the ceiling of the furnace.room and shall extend to the ex­ terior or the bu.ild1ng through a me'te.1 duct • . (g) T:b.e furnace shall be vented to a regula t1on V11ant a,s specified ir.i this Chapter; The above and foregoing ord1nance vas duly and regularly introduced at a regul~ meeting ot' the Council or the City c1f Palo Al to held on Monday, the 9th day of March, 1942, and was thereafter on Monday, the 13th day of April, 1942, duly and regularly adopted by the following vote: AYES: NOES: ABSENT: Bentrott, Blo1s, Cypher, Hoy, Morton, Reed, Southwood, Tho1ts. None. Ca;shel. Merner, Mitchell, Radford, Richards, TholllS:s, Wood. · I, WINIFRED :KIDD, City Clerk of the City of Palo Alto, hereby certfty:thatthe above and foregoing ordinance wa.s duly and regularly pa:seed by the Council of the City of Palo Alto,,. as .follows: F1i .. st reading on the 9th dsy of March, 1942; second reed1:11g; and ps.sss.ge on the 13th day or April, 19l.t2. -~ -